The improvement potential of ultrafast all-optical switching by soliton self-trapping, using all-solid dual-core fibres with high index contrast, was analyzed numerically. The study of the femtosecond nonlinear propagation was performed based on coupled generalised nonlinear Schrödinger equations considering three fibre architectures: homogeneous cladding all-solid, photonic crystal air-glass, and photonic crystal all-solid. The structural geometries of all three architectures were optimised in order to support high-contrast switching performance in the C-band, considering pulse widths at the 100 fs level. Comparing the three structural alternatives, the lowest switching energies at common excitation parameters (1700 nm and 70 fs pulses) were predicted for the homogeneous cladding dual-core structure. Further optimization of the excitation wavelength and pulse width resulted in lower switching energies and simultaneous improvement of the switching contrasts at the combination of 1500 nm, 75 fs pulses and a fibre length of 43 mm. The spectral aspect in this optimised case expresses a broadband and uniform switching character with a span of over 200 nm and a contrast exceeding 30 dB at more frequency channels.
In the presented work, the potential of fiber-optic distributed acoustic sensing (DAS) for detection of small gas pipeline leaks (<1%) is investigated. Helical wrapping of the sensing fiber directly around the pipeline is used to increase the system sensitivity for detection of weak leak-induced vibrations. DAS measurements are supplemented with reference accelerometer data to facilitate analysis and interpretation of recorded vibration signals. The results reveal that a DAS system using direct fiber application approach is capable of detecting pipeline natural vibrations excited by the broadband noise generated by the leaking medium. In the performed experiment, pipeline vibration modes with acceleration magnitudes down to single ug were detected. Simple leak detection approach based on spectral integration of time-averaged DAS signals in frequency domain was proposed. Potential benefits and limitations of the presented monitoring Approach were discussed with respect to its practical applicability. We demonstrated that the approached is potentially capable of detection and localization of gas pipeline leaks with leak rates down to 0.1% of the pipeline flow volume and might be of interest for monitoring of short- and medium-length gas pipelines.
Along temperature, humidity is one of the principal environmental factors that plays an important role in various application areas. Presented work investigates possibility of distributed fiberoptic humidity monitoring based on humidity-induced strain measurement in polyimide (PI)-coated optical fibers. Characterization of relative humidity (RH) and temperature response of four different commercial PI- and one acrylate-coated fiber was performed using optical backscattering reflectometry (OBR). The study addresses issues of temperature-humidity cross sensitivity, fiber response stability, repeatability, and the influence of annealing. Acrylate-coated fiber exhibited rather unfavorable nonlinear RH response with strong temperature dependence, which makes it unsuitable for humidity sensing applications. On the other hand, humidity response of PI-coated fibers showed good linearity with fiber sensitivity slightly decreasing at rising temperatures. In the tested range, temperature sensitivity of the fibers remained humidity independent. Thermal annealing was shown to considerably improve and stabilize fiber RH response. Based on performed analysis, a 20 m sensor using the optimal PI-coated fibers was proposed and constructed. The sensor uses dual sensing fiber configuration for mutual decoupling and simultaneous measurement of temperature and RH variations. Using OBR, distributed dual temperature-RH monitoring with cm spatial resolution was demonstrated for the first time.
The feasibility study „AGIFAMOR. Ageing infrastructures – distributed acoustic monitoring of pipes” is an interdisciplinary research project at BAM internally financed from 2015 to 2018. Therefore, the quite young fibre optic sensing technology of distributed acoustic sensing (DAS) was investigated to possibly be extended towards a global condition monitoring system for pipelines operating in real time.
DAS is a highly dynamic fibre optic sensing technology based on the method of coherent optical time domain reflectometry (C-OTDR). DAS allows capturing strain changes in the range of kHz. For the experimental work, the most suitable application yielding an optimum sensitivity was proven by wrapping a standard single-mode silica fibre around the pipe.
The DAS sensitivity was investigated regarding the detection of 1) incidents that initiate propagation of acoustic waves in the pipe wall, 2) changes inside the pipeline causing altered flow and 3) damage development in the pipe wall. Therefore, several testing setups in laboratory as well as in real scale were realized. For comparison purposes, experiments were accompanied by acoustic emission analyses and by measurements with accelerometers.
DAS was found to be very sensitive to gas ignition and its propagation across the pipe. Furthermore, the ability of DAS to detect and localize acoustic signals associated with pipeline leakage was demonstrated. The detection of crack formation and propagation within the pipe wall by means of DAS was studied during bending tests on several pipe segments, but was not proven so far with certainty. As expected, these studies turned out as the most difficult challenge due to the random occurrence and transient nature of microscopic damage phenomena.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Distributed humidity/water sensing is sought after in wide range of applications including concrete condition monitoring in civil engineering, SHM of large structures such as dykes or dams, soil moisture measurement in agriculture or leak detection in pipeline or sewage industry. Using humidity-induced strain of specialty hygroscopic coating materials, such as polyimide (PI) seems as the most promising approach so far. In this work, relative humidity and temperature response of different commercial PI-coated and tight-buffer fibers is investigated for the development of distributed humidity sensor.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Distributed humidity/water sensing is sought after in wide range of applications including concrete condition monitoring in civil engineering, SHM of large structures such as dykes or dams, soil moisture measurement in agriculture or leak detection in pipeline or sewage industry. Using humidity-induced strain of specialty hygroscopic coating materials, such as polyimide (PI) seems as the most promising approach so far. In this work, relative humidity and temperature response of different commercial PI-coated and tight-buffer fibers is investigated for the development of distributed humidity sensor.
Humidity is one of principal environmental parameters that plays an important role in various application areas. Using measurement of strain induced in an optical fiber by a water swellable coating represents a promising approach for realization of distributed humidity sensing (DHS). In this work, humidity and temperature response of four different commercial PI-coated fibers and four tight-buffered (TB) fibers is investigated with the aim of evaluating their potential for development of DHS in context of water ingress sensor for high-voltage power cable splices. PI-coated fibers exhibited close-to-linear humidity and temperature response. While the temperature response is relatively coating-independent, magnitude of humidity response was broadly correlated to the relative fiber-to-coating thickness ratio. In contrast, both humidity and temperature response of TB fibers is strongly influenced by buffer type, with Leoni TB900L fiber with Hytrel buffer exhibiting largest humidity and temperature sensitivity. While the response of tight-buffered fibers is generally nonlinear, roughly three-times higher humidity response can be achieved with TB900L compared to the most sensitive PI-coated fiber. Using the TB fiber can be, therefore, advantageous for simpler water detection applications, such as one targeted in this study, when larger sensitivity is more important than the linear response of the sensor.
The mechanical stress-strain behaviour of polymer optical fibres (POFs) drawn from various materials was measured, both before and after temperature annealing of the POFs. The POFs were drawn from PMMA (GEHR), Zeonex (480R), PC (Makrolon LED2245) and two different grades of Topas (8007S-04 and 5013S-04). With fibre drawing stresses at or above the elastic (uniaxial extensional) plateau modulus, the polymer chains in the POFs have a high degree of alignment, which has a large impact on fibre mechanical behaviour. The testing was performed at straining rates ranging from 0.011%/s, to 1.1%/s for the un-annealed fibres and a straining rate of 1.1%/s for the annealed ones. The elastic modulus of the tested POFs showed no sensitivity toward variation of straining rate. In the case of Topas 5013S-04 and PMMA, the producer-reported values are the same as the one obtained here for the POFs both before and after annealing. The drawn POFs made of Zeonex, PC, and Topas 8007S-04 exhibit larger elastic modulus than the respective materials in the bulk form. The elastic modulus of these fibres is reduced upon annealing by 10-15%, but still remains above the producer-reported values for the bulk polymers. In the nonlinear elastic region, only the PC POF is statistically unaffected by the changes in the straining rate, while Topas 8007S-04 POF shows insensitivity to the straining rate until 3% strain. All other changes affect the stress-strain curves. The annealing flattens all stress-strain curves, making the fibres more sensitive to yield.
The monitoring of oil and gas pipelines by means of distributed fibre optic sensors is becoming common. The most recent development in the field of fibre optic sensing is the distributed acoustic sensing (DAS), which allows to detect and to localize third party threats to pipelines. For this purpose, fibre optic telecommunication cables located close to the pipelines are usually used. However, DAS carries a far greater potential for continuous condition monitoring of pipelines.
The interdisciplinary research project AGIFAMOR (Ageing Infrastructures – Fibre Optic Monitoring of Pipes) at BAM investigates a new technical approach to extend the application field of DAS towards the detection and localization of acoustic signals that indicate critical alterations and certain damage scenarios originated from within the pipeline or the pipe wall. Therefore, the optical fibre sensors are applied onto the pipe itself and the application procedure towards an optimal acoustic signal transduction is optimized.
A number of laboratory scale experiments were performed focusing on the signal transmission of acoustic signals as well as the detection of damages in the pipe wall by means of DAS. Furthermore, real-scale tests on a pipeline DN100 of 38m length have been carried out at the BAM test site for technical safety (BAM-TTS) to study the detection and localization of leaks and of changing flow profiles due to corrosion or sedimentation processes.