Filtern
Dokumenttyp
- Vortrag (54)
- Zeitschriftenartikel (49)
- Beitrag zu einem Tagungsband (38)
- Posterpräsentation (20)
- Buchkapitel (3)
- Forschungsdatensatz (3)
- Beitrag zu einem Sammelband (1)
- Dissertation (1)
Sprache
- Englisch (169) (entfernen)
Schlagworte
- Distributed acoustic sensing (28)
- Structural health monitoring (20)
- DAS (16)
- Distributed fiber optic sensing (16)
- Distributed fiber sensing (15)
- Machine learning (14)
- Artificial neural networks (13)
- Distributed sensing (11)
- Acoustic sensing (10)
- BOFDA (10)
Organisationseinheit der BAM
- 8.6 Faseroptische Sensorik (169) (entfernen)
We demonstrate (and are the first to do so) 63 km Brillouin Optical Frequency-Domain Analysis (BOFDA) for temperature and strain monitoring using a 100 km fiber loop. The use of BOFDA for long-range applications can be considered a novel approach, as previous investigations focused on the utilization of Brillouin Optical Time-Domain Reflectometry and Analysis (BOTDR and BOTDA, respectively). At 51.7 km, a 100 m hotspot (37 °C) was detected without using distributed Raman amplification or image processing.
We present, to our knowledge for the first time, a 100-km Brillouin Optical Frequency-Domain Analysis (BOFDA) employing a 200-km fiber loop. Compared to our previous publication, enhanced sensor length, sensor accuracy and spatial resolution are presented. The performance improvements are achieved by applying distributed Raman amplification (DRA) and a digital high-pass filter. We report on temperature measurements over sensing distances of 75 km and 100 km both with a 12.5-m spatial resolution. Temperature changes of 5 °C have been measured along 75 km sensing fiber. A temperature change of 30 °C has been detected at 99.5 km.
We present a temperature sensor based on a polymer exhibiting a Lower Critical Solution Temperature (LCST) in aqueous solution encapsulated in a capillary. Parameters are chosen such that the solution exhibits a cloud point in a temperature range of 30° C to 39°C. The characteristic of thermoresponsive polymers with an LCST, is that above that temperature phase separation of the polymer takes place which leads to a temperature-dependent formation of a cloudy suspension. An optical intensity measurement over the desired temperature range is established by an increase of optical attenuation inside the polymer solution caused by a rising temperature. For our purpose, the polymer capillary is connected to transmitter and receiver via a Polymer Optical Fibre (POF). Our intensity measurement is, to the best of our knowledge, a novel method and can be considered simple when compared to existing fibre-based temperature measurement techniques. Due to the lack of electrical components at the probe, this sensor is suitable for measurements in strong electromagnetic fields and environments for which flying sparks are hazardous, i.e., inflammable fluids or gases. Furthermore, all manufactured sensors share the same temperature dependence and, therefore, are well-suited for comparative measurement, e.g., flow measurement systems. With the given temperature range, a body temperature measurement is also suitable.
We demonstrate the use of a 3D printed radial collimator in X-ray powder diffraction and surface sensitive grazing incidence X-ray diffraction. We find a significant improvement in the overall Signal to background ratio of up to 100 and a suppression of more than a factor 3⋅10⁵ for undesirable Bragg reflections generated by the X-ray “transparent” windows of the sample environment.
The background reduction and the removal of the high intensity signals from the windows, which limit the detector’s dynamic range, enable significantly higher sensitivity in experiments within sample environments such as vacuum chambers and gas- or liquid-cells. Details of the additively manufactured steel collimator geometry, alignment strategies using X-ray fluorescence, and data analysis are also briefly discussed. The flexibility and affordability of 3D prints enable designs optimized for specific detectors and sample environments, without compromising the degrees of freedom of the diffractometer.
The influence of size effects on the thermoelectric properties of thin platinum films is investigated and compared to the bulk. Structural properties, like the film thickness and the grain size, are varied. We correlate the electron mean free path with the temperature dependence of the electrical conductivity and the absolute Seebeck coefficient SPt of platinum. A measurement platform was developed as a standardized method to determine SPt and show that SPt,film is reduced compared to SPt,bulk. Boundary and surface scattering reduce the thermodiffusion and the phonon drag contribution to SPt,film by nearly the same factor. We discuss in detail on behalf of a model, which describes the temperature dependence of the absolute Seebeck coefficient, the influence of size effects of electron-phonon and phonon-phonon interaction on SPt.
Monitoring of construction projects plays increasingly important role in the implementation of growing needs and requirements, especially in geologically difficult areas. This particularly concerns tunnelling and special civil engineering projects. The use of fiber optic sensors for structural health monitoring provides significant economic advantages regarding lower life-cycle costs of the civil infrastructure. We present our achievements in the development of distributed polymer optical fiber sensors based on Rayleigh and Brillouin scattering for early damage detection.
Acoustic emission testing
(2018)
The improvement potential of ultrafast all-optical switching by soliton self-trapping, using all-solid dual-core fibres with high index contrast, was analyzed numerically. The study of the femtosecond nonlinear propagation was performed based on coupled generalised nonlinear Schrödinger equations considering three fibre architectures: homogeneous cladding all-solid, photonic crystal air-glass, and photonic crystal all-solid. The structural geometries of all three architectures were optimised in order to support high-contrast switching performance in the C-band, considering pulse widths at the 100 fs level. Comparing the three structural alternatives, the lowest switching energies at common excitation parameters (1700 nm and 70 fs pulses) were predicted for the homogeneous cladding dual-core structure. Further optimization of the excitation wavelength and pulse width resulted in lower switching energies and simultaneous improvement of the switching contrasts at the combination of 1500 nm, 75 fs pulses and a fibre length of 43 mm. The spectral aspect in this optimised case expresses a broadband and uniform switching character with a span of over 200 nm and a contrast exceeding 30 dB at more frequency channels.
Application of Intensity-Based Coherent Optical Time Domain Reflectometry to Bridge Monitoring
(2022)
Although distributed fiber sensing techniques have been widely used in structural health monitoring, the measurement results of bridge monitoring, particularly under destructive testing, have rarely been reported. To the best of our knowledge, this paper is the first report of distributed vibration measurement results, which we obtained during a three-day destructive test on an abolished bridge. A coherent optical time domain reflectometry (COTDR) was used to acquire the vibration information while the bridge was being sawed. The obtained signal was analyzed in time and frequency domain. Some characteristics of the sawing-induced vibration were retrieved by the short-time Fourier transform; the vibration exhibited several high frequency components within the measured range up to 20 kHz and all the components appeared in the same time slot. Some unexpected signals were also detected. Thorough analysis showed that they are quite different from the sawing-induced vibration and are believed to originate from internal damage to the bridge (probably the occurrence of cracks).