Filtern
Dokumenttyp
- Vortrag (5)
- Posterpräsentation (2)
Sprache
- Englisch (7) (entfernen)
Referierte Publikation
- nein (7) (entfernen)
Schlagworte
- Schnelltest (7) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (5)
Antibody-based analytical techniques have gained increasing importance in environmental analysis. Rapid assays, portable devices and formats that require a limited number of steps have a high potential for on-site analysis in outdoor environments or in environmentally relevant facilities such as wastewater treatment plants. Many of these methods have become more sensitive and more versatile due to new, advanced materials, such as novel particles, specifically prepared surfaces, new labels, specifically coated electrodes etc. The talk shows some of our works in this context.
A vast number of emerging pollutants is being detected in the environment. Another lingering problem are health-threatening contaminants, such as mycotoxins, that deteriorate food and feed.
Analytical methods, suitable for trace analysis, are needed that are desirably also fast, inexpensive and, if possible, robust, and portable. Immunoanalytical, i.e., anti-body-based technologies, which are available in a broad range of formats, can be profitably used here to analyze for the distribution and the concentration trends of contaminants.
Some of these formats are single-analyte but high-throughput methods. To use them wisely, indicator substances or sum parameters must be established to be used in screening approaches. Other methods are suitable to be performed on portable in-strumentation in the field (on-site), more precisely at the point-of-need. Furthermore, there are array technologies that allow for parallel analysis of several analytes of interest (multiplexing). The talk reports on methods and data for compounds con-sidered as anthropogenic contamination markers (the antiepileptic carbamazepine, the analgesic diclofenac, the anti-histaminic cetirizine, the steroid hormone estrone, the antimicrobial amoxicillin, the stimulants caffeine and cocaine, the endocrine disruptor bisphenol A, and a bile acid). Some work on mycotoxins (ochratoxin A and ergot alkaloids) is also presented. It is demonstrated that antibody-based technolo-gies have a huge potential to gain analytical insights at the point-of-need.
Drug facilitated sexual assaults (chemical submission) consists in the criminal administration of psychoactive substances without the permission of the victim. Among these compounds, scopolamine (SCP) (commonly well-known as burundanga} has emerged as the perfect psychotropic substance for aggressors because its ingestion induces automatism in the brain of the victim causing a state of submission. Physiologically, an appealing feature of SCP is their relevant role as a non-competitive muscarinic acetylcholine receptor antagonist with rapid and robust antidepressant effects in humans and other species. Specifically, SCP is able to block or dampen the biological response because of binding to an allosteric recombinant human muscarinic acetylcholine receptor M2/CM2 (Mi-AChR) site that is separate from the active recognition site of acetylcholine, thereby inhibiting the effects of the natural substrate and even of a potent agonist such as bethanechol. Here, a straightforward portable strip in combination with bioinspired hybrid nanomaterials for SCP drug in situ and at site detection was developed. The strips allow direct identification of SCP in diluted saliva down to 40 nM in less than 15 min using a smartphone for readout. For this purpose, we prepared a nanosensor based on mesoporous silica nanoparticles {MSNs) loaded with a fluorescent dye and functionalized with bethanechol. Attachment of the M2-AChR 'cap' to the silica scaffold enabled pore closure through non-covalent recognition. interactions with the anchored bethanechol moieties. In the presence of SCP pores were opened, due to the preferential interaction of the drug with receptor, thus releasing the encapsulated reporter and allowing it to be detected. Additionally, to a single-track strip, the extraordinary modularity of the hybrid biosensor materials in combination with the strip-pattering technologies enabled us to obtain a dual-channel strip for SCP and cannibal drug detection in a simple way, providing comparable analytical performance, while enabling further tailoring to the user's needs.
γ-Hydroxybutyric acid (GHB) is a natural metabolite, which is currently used as a date rape drug. Particularly, GHB is rapidly eliminated and its detection in realistic environments is only possible within 6-12 h after ingestion. Owing to the increasing use of GHB for criminal purposes, a need has arisen to develop simple and in situ efficient assays for its identification in aqueous and alcoholic drinks. Based on the above, we report herein an indicator displacement assay (IDA) for GHB detection that consists of a Cu2+ complex with a tetradentate ligand and the fluorescent dye coumarin 343 (IDA probe 1). Firstly, the tetradentate ligand was synthesized by reductive amination of a 1,2-cyclohexyl diamine with 2-quinoline carboxaldehyde. Subsequently, this ligand was reacted with Cu(CF3SO3)2 to obtain the corresponding copper complex, which generates the final sensing ensemble by coordinating with coumarin 343 (IDA probe 1). The sensing mechanism relies on a displacement of coumarin 343 from the sensing ensemble 1 thus restoring its fluorescence, as a consequence of the higher binding constant between GHB and complex, showing a high sensitivity in MES buffer (50 mM, pH 6.0) (detection limit of 0.03 μM). Likewise, system design and optimization led to a straightforward integration into a lateral-flow assay without further treatment or conditioning of the test strips while guaranteeing fast overall assay times of 1 min (Figure 1). In this way, IDA probe 1 was incorporated into a coated PEG-glass fibre (PEG-GF) membrane to obtain a highly robust and sensitive lateral flow assay for GHB detection in spiked alcoholic drinks with a detection limit of 0.1 μM in less than 1 min coupled to smartphone readout.
The globe's seas were used as dumping ground after the world wars and those millions of ammunition, most of all containing 2,4,6-trinitrotoluene (TNT), represent a pressing danger for fishermen, dredging operations, submarine cable installations and tourism. We developed an extremely selective indication method for TNT based on a specific reaction that produces a highly fluorescent compound. The indication system was integrated into a microfluidic PDMS chip for the solid-liquid extraction of TNT from water samples, offering environmental monitoring possibilities. Combining the advantages of a light-up indicator, microfluidics and a smartphone as detector, the embedded sensor allows for the remote and rapid detection of TNT down to ng in surface and sea waters.
A vast number of emerging pollutants has been detected in the environment over the last decades. Analytical methods suitable for trace analysis are needed that are desirably also fast, inexpensive and, if possible, robust and portable. Immunoanalytical, i.e. antibody-based, methods which are available in a broad range of formats, can be profitably used here to analyse for the distribution and the trends of concentration levels of contaminants in the environment. Some of these formats are single-analyte but high-throughput methods. In order to use them wisely, indicator substances, sometimes called anthropogenic markers, should be selected and used in screening approaches. Other methods are suitable to be performed on portable instrumentation in the field (on-site) or in facilities such as wastewater treatment plants for on-line monitoring. Furthermore, there are array technologies that allow for parallel (multiplex) analysis of several analytes of interest.
The microtiter-plate based ELISA (Enzyme-linked Immunosorbent Assay) is the method of choice for the analysis of a large number of samples [1]. ELISAs are available to monitor for anthropogenic markers such as the antiepileptic carbamazepine, the analgesic diclofenac, the antihistaminic cetirizine, the steroid hormone estrone, the antimicrobial sulfamethoxazole, the stimulants caffeine and cocaine, the priority pollutant bisphenol A, and the bile acid isolithocholic acid. For on-site screening and monitoring, simpler formats, like mix-and-read assays, e.g. the Fluorescence Polarization Immunoassay (FPIA) [2] or Lateral-flow Immunoassays (LFIA) [3] are more suitable tools, the latter based on dipsticks or cassettes, that is why they are also called pregnancy test-like assays. The suitability of multi-analyte formats such as immunomicroarrays depends on the choice of a signal-producing system that provides small uncertainties and good reproducibility of the measurements. Bead-based (“suspension”) arrays read out in flow cytometers are a powerful platform for multiplex assays [4]. Electrochemical formats run on portable devices provide additional advantages as no light source is required. They are most promising for stand-alone analysers and biosensors
Rapid tests and assays to be used outside of a laboratory for non-trained personal and also at a point of need are becoming increasingly important in areas such as health, food, security, or the environment. Specially on that regard, paper-based sensors are emerging as a new class of devices because they fulfil the requisites of the "World Health Organization" to be ASSURED: affordable, sensitive, specific, user-friendly, rapid and robust, equipment free and deliverable to end-users. The physical, chemical and mechanical properties of cellulose or glass fiber paper in combination with the facility of preparation are making these materials of great interest while looking for cost-efficient and green alternatives for device production technologies. To improve the sensitivity of these systems, a particularly promising approach is the employment of gated indicator delivery systems using preorganized nanoscopic solid structures incorporated on paper strips to produce an exponential amplification of the detectable signal. Having in mind these concepts, several examples of (bio)gated materials incorporated into sensing membranes will be presented for the detection of small organic molecules, having fluorescence or electrochemiluminescence signal as output signal. Compared with fluorescence, it has been demonstrated that the non-optical excitation has significantly reduced the background signal, and with the help of a portable potentiostat in combination with a home-made 3D-printed case fitted onto a smartphone, the sensitivity of the sensing system has been improved tremendously, from the lower ppb range (fluorescence) to the lower ppt range. With this study, the applicability of ECL detection on paper strips in combination with gated indicator-releasing materials has been demonstrated for the first time, presenting a novel synergistic match. Considering the modularity of the system developed, the platform technology potential is obvious, promising expansion of the general concept to many other analytes, applications and scenarios.