Filtern
Erscheinungsjahr
- 2017 (7) (entfernen)
Dokumenttyp
- Forschungsbericht (7) (entfernen)
Sprache
- Englisch (7) (entfernen)
Referierte Publikation
- nein (7)
Schlagworte
- CONSENS (1)
- Cement (1)
- Classification (1)
- Dangerous goods (1)
- Delta value (1)
- EU definition of a nanomaterial (1)
- Gefahrgut (1)
- Gefahrstoff (1)
- Hazardous substances (1)
- Indirect Hard Modeling (1)
Isotope amount ratios (hereafter referred to as simply isotope ratios) are proving useful in an ever increasing array of applications that range from studies unravelling transport processes, to pinpointing the provenance of specific samples as well as trace element quantification by using isotope dilution mass spectrometry (IDMS). These expanding applications encompass fields as diverse as archaeology, food chemistry, forensic science, geochemistry, medicine and metrology. However, to be effective tools, the isotope ratio data must be reliable and traceable to enable the comparability of measurement.
The importance of traceability and comparability in isotope ratio analysis has already been recognized by the Inorganic Analysis Working Group (IAWG) within the CCQM. Three pilot studies have focused on the quality of isotope ratio determinations (P48 “U isotope ratios in urine”, P75 “stable isotopes in Methionine”, P105 “87Sr/86Sr in wine”). Moreover, isotope ratio measurements are fundamental to IDMS amount of substance determinations. For example, when Pb quantification using IDMS is undertaken, this requires the measurements of Pb isotope ratios. While the requirements for isotope ratio accuracy and precision in the case of of IDMS are generally quite modest, “absolute” Pb isotope ratio measurements for geochemical age dating and source rock characterization as well as forensic provenance and fingerprinting studies require Pb isotope ratio measurements of the highest quality. To support present and future CMCs on isotope ratio determinations, a Key Comparison was urgently needed. Therefore, it was decided at the IAWG meeting in Paris in April 2011 that a Key Comparison on the determination of Pb isotope ratios in a pure Pb solution and in a bronze sample should be organized and accompanied by a pilot study.
Measuring Pb isotope amount ratios in a pure Pb solution, while seemingly straight forward, rigorously tests the ability of analyst to correct for any instrumental effects (such as mass discrimination and blank correction) on the measured ratios. Pb, present in trace amounts in a metal matrix sample (e.g. Pb in bronze), provides a real world test of the whole chemical and instrumental procedure, from chemical separation and sample purification to analysis and subsequent correction of appropriate instrumental effects on the separated samples.
A suitable bronze material with a Pb mass fraction between 10 and 100 mg·kg-1 was available at BAM. A high purity solution of Pb with a mass fraction of approximately 100 mg·kg-1 was also available. By comparing the Pb isotope ratio results obtained for the bronze sample with the Pb isotope ratio results from the Pb solution, potential biases arising from the processing of the bronze sample could be effectively identified and separated from the instrumental effects arising from the measurement and data processing protocol.
Validation report on NMR
(2017)
The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug and play integration, even though they may appear to be more complex at first sight. Smart sensors enable concepts like self-diagnostics, self-calibration, and self-configuration/ parameterization whenever our current automation landscape allows it.
Here we summarize the currently discussed general requirements for process sensors 4.0 and introduce a smart online NMR sensor module as example, which was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (www.consensspire.eu).
The cement proficiency testing (PT) scheme was set up by the German Metrology Institute (PTB) and the Federal Institute for Materials Research and Testing (BAM) in 2012. The PT scheme was a spin-off from a European Commission and African, Caribbean and Pacific-Group of States funded project entitled SPIN – Spearhead Network for Innovative, Clean and Safe Cement and Concrete Technologies (www.spin.bam.de). The SPIN project aimed at crosslinking experts in industry and policy making bodies, with the prospect of establishing a sustainable cement and concrete construction capacity in Africa.
After a successful first pan-African proficiency testing scheme in 2012/2013, it was decided to establish the scheme permanently and independent of the SPIN project.
The main focus of setting up a testing scheme was to enable all cement testing laboratories in Africa to evaluate their competence and efficiency in cement testing and further enhance their capacity to obtain better quality products according to their environment. The acronym developed for the PT scheme is PACE-PTS (Pan-African Cement Proficiency Testing Scheme). The framework for the PT scheme was set up jointly among the organisers and the first participants. The first PT scheme was initiated in Dar Es Salaam in 2012 followed by a final workshop in Berlin in 2013. The second PT scheme began in 2014. A final workshop was organised in Dar es Salaam in 2015. The third and current scheme was started in 2016 and the final workshop is held in Yaoundé.
In October 2011 the European Commission (EC) published a "Recommendation on the definition of na-nomaterial" (2011/696/EU), to promote consistency in the interpretation of the term "nanomaterial" for legislative and policy purposes in the EU. The EC NM Definition includes a commitment to its review in the light of experience and of scientific and technological developments. This review is ongoing in 2017 and as a contribution to the review the Joint Research Centre of the European Commission (JRC) has already developed a series of three scientific-technical reports with the title: “Towards a review of the EC Recommendation for a definition of the term nanomaterial” which provides to the EC policy services sci-ence-based options on how the definition could be revised or supported with additional guidance.
The overarching nature and wide scope of the EC NM Definition, as it does not exclude a priori any particulate material regardless the state, form and size, creates many analytical challenges in its imple-mentation for all stakeholders, including enterprises and regulators.
The NanoDefine project has as core objective to support the implementation of the EC NM Definition. In an earlier report1 key aspects of the EC NM Definition were addressed, with the goal to improve the implementability of the EC NM Definition. Based on further developments and results obtained in NanoDefine project that first report was updated and is presented here. The key aspects are discussed based on the results of four years of research performed within the framework of the project. As a result this report assesses how well the requirements of the EC NM Definition can be fulfilled with currently available analytical possibilities. It presents recommendations and options on a revision of the EC NM Definition to improve the implementability of the definition based on currently available analytical possi-bilities, according to the state of the art in 2017. Of the technical issues considered in this report, the following seem to deserve the most attention in terms of clarification of the definition and/or provision of additional implementation guidance: 'external dimension', ‘number based particle size distribution‘, ‘polydispersity‘ and ‘upper size limit‘, the term ‘particle’, the ‘means to prove that a material is not a nanomaterial‘ and ‘the role of the volume specific sur-face area (VSSA)‘, and "particulate materials'.
The test methods UN Test L.2 / EN ISO 9038:2013 DIN EN 15188:2007 are applied to characterize the sustained combustibility of liquids i.e. the behaviour of a material under specified test conditions, whereby its vapour can be ignited by an ignition source and sufficient flammable vapour is produced to continue burning for at least 15 s after the source of ignition has been removed.
The aims of this interlaboratory test (IT) are the verification and/or the improvement (if necessary) of the verification data (reference material) in Annex B of EN ISO 9038:2013, the assessment of influencing (disturbing) factors (laboratory specific factors, which possibly may have an influence on the test result) and the assessment of the performance of the participating laboratories.
It could be demonstrated that the reference materials n-Dodecane, n-Decane and n-Undecane as mentioned in the standard are suitable and the verification shall continue to be valid.
Sustained combustibility tests are influenced by several factors like the presence of a draught shield, the experience of the laboratory assistant, verification of the apparatus, calibration of the metering device.
Based on the interlaboratory test, the gained experience and the actual results, well-founded measures / actions can be recommended to improve execution of the method.
The IT was organized by PTB, BAM and QuoData GmbH in the framework of the co-operation project CEQAT-DGHS Centre for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances.
The VSSA approach has the important advantage over classifying, imaging and counting techniques that it does not involve dispersion protocols. Further, the BET technique as the basis for VSSA determination it is in widespread use, generates low costs and is specified for many commercial materials. Finally, the same equipment allows for a deeper analysis by full isotherm evaluation.
The present deliverable assesses all NanoDefine powders, supplemented by further real-world materials (in total 26 powders), and quantitatively compares the relationship between the median size (by Electron Microscopy – considered as benchmark for the EC nanomaterial definition) vs. the size derived from VSSA. The VSSA method mitigates the challenges of EM to assess the thickness of platelets, but worked as well on fibbers and particles of irregular shapes. A screening strategy is proposed. If applied to the further data from real-world materials as validation set, this screening does achieve a correct classification, leaving only borderline materials for tier 2 assessment.