Filtern
Erscheinungsjahr
- 2020 (139) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (65)
- Vortrag (31)
- Beitrag zu einem Tagungsband (21)
- Sonstiges (13)
- Buchkapitel (3)
- Posterpräsentation (3)
- Dissertation (2)
- Handbuch (1)
Sprache
- Englisch (139) (entfernen)
Schlagworte
- Corrosion (17)
- Durability (8)
- Coating (7)
- Flame retardant (7)
- Alkali-activated materials (6)
- Concrete (6)
- Stainless steel (5)
- UHPC (5)
- Architectural Concrete (4)
- Damage characterization (4)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (139) (entfernen)
Paper des Monats
- ja (4)
Eingeladener Vortrag
- nein (31)
Polymers that help tailoring rheological properties during the casting process have become inevitable constituents for all kinds of high-performance concrete technologies. Due to lacking industries, these typically crude-oil based admixtures are not readily available in many parts of the world, which limits the implementation of more sustainable high-performance construction technologies in these regions. Alternative polymers, which often demand for less processing, can be derived from local plant-based resources. The paper provides experimental data of flow tests of cement pastes with polysaccharides from Triumfetta pendrata A. Rich, acacia gum and cassava without and in the presence of polycarboxylate ether superplasticizer. The flow tests are amended by observations of the zeta potentials and the hydrodynamic diameters in the presence of and without calcium ions in the dispersion medium. The results show that in the presence of and without calcium ions all polysaccharides provide negative zeta potentials, yet, they affect flowability and thixotropy in different ways. Cassava starch, acacia gum, and the gum of Triumfetta pendrata A. Rich qualified well for robustness improvement, strong stiffening, and additive manufacturing, respectively. The reason for the different effects can be found in their average sizes and size distribution. Due to the promising results, a flow chart for local value chains is derived on the example of yet unused cassava wastes, which can be converted in parallel.
Non-conventional densely packed concrete mixtures are proposed and evaluated in this paper using engineered recycled mineral admixtures and recycled aggregates obtained from steel slag, quartz mining tailings, and quartzite mining tailings. High fines content sand-concretes containing coarser- and finer-than-cement recycled powders were designed to obtain blends with broader particle-size ranges and improved packing density. As a result, compressive strength up to 99 MPa, cement intensity up to 2.33 kg/m³/MPa, and consumption of recycled material up to 95 vol% were obtained. Compressive strengths up to 66 MPa and cement intensity up to 2.34 kg/m³/MPa were also obtained with the addition of coarse aggregates to such sand-concrete mixtures, with consumption of recycled material up to 96.5%. The results launch new insights on the role of recycled admixtures and aggregates on the mixture design of cement-based composites regarding efficiency improvement and technological performance.
Design : and use of engineered recycled mineral admixtures obtained from industrial and mineral waste are promising strategies to increase the range of materials suitable for use in cement-based composites. In this work, Portland cement-blended pastes containing mineral admixtures designed for improving particle packing were evaluated in the presence of low- and high-charge polycarboxylate-based superplasticizers. The powders were obtained from basic oxygen furnace slag, iron ore tailings, quartz mining tailings, and quartzite mining tailings. The zeta-potentials of the particles were obtained via electrophoretic mobility. The flow properties were evaluated by rheological tests performed in a Couette type rheometer. The hydration kinetics was evaluated by isothermal calorimetry and an adapted method based on the Vicat needle test. The high-charge PCE and the finer mineral admixtures produced more stable blends. Coarser mineral admixtures led to increased flowability and delayed hydration compared to finer ones. Steel slag powders presented the most significant plasticizer effects, but also the largest setting delays and segregation tendency. Quartz-rich superfines reduced the setting delays caused by the superplasticizers. In summary, both superplasticizers were effective in improving flow properties, but the high-charge PCE was effective in preventing segregation in pastes containing mineral admixtures coarser and heavier than cement.
Two types of cements were selected as the reference cement in the priority program 2005 of the German Research Foundation (DFG SPP 2005). A thorough characterization of CEM I 42.5 R has been made in a recent publication. In this paper, the characterization data of the other reference cement CEM III/A 42.5 N are presented from the aspects of chemical and mineralogical compositions as well as physical and chemical properties. The characterization data of the slag, which is the second main constituent of this specific cement besides the clinker, are presented independently. For all data received, the mean values and the corresponding errors were calculated. The data shall be used for the ongoing research within the priority program. Also, researchers from outside this priority program can benefit from these data if the same materials are used.
Supplementary cementitious materials (SCM) can reduce the total amount of Portland cement clinker in concrete production. Rice husk ashes (RHA) can be converted from an agricultural by-product to a high-performance concrete constituent due to a high amount of reactive silica with pozzolanic properties if they are burnt under controlled conditions. The way and duration of combustion, the cooling process as well as the temperature have an effect on the silica form and thus, the chemical and physical performance of the RHA. Various studies on the best combustion technique have been published to investigate the ideal combustion techniques. Yet, the process mostly took place under laboratory conditions. Investigating the difference between the performance of RHA produced in a rural environment and laboratory conditions is useful for the assessment and future enhancement of RHA production, and its application both as building material, for example in rural areas where it is sourced in large quantities, and as additive for high performance concrete. Thus, the paper presents a comparison between RHA produced under rudimentary conditions in a self-made furnace in the rural Bagamoyo, Tanzania and under controlled laboratory conditions at the Technical University of Munich, Germany, with different combustion methods and temperatures. In a second step, RHA was ground to reach particle size distributions comparable to cement. In a third step, cement pastes were prepared with 10%, 20% and 40% of cement replacement, and compared to the performance of plain and fly ash blended cement pastes. The results show that controlled burning conditions around 650 °C lead to high reactivity of silica and, therefore, to good performance as SCM. However, also the RHA burnt under less controlled conditions in the field provided reasonably good properties, if the process took place with proper burning parameters and adequate grinding. The knowledge can be implemented in the field to improve the final RHA performance as SCM in concrete.
Flexible joint transition systems in the form of bituminous joint transitions, type 4.1a according to RTD1007-1, have been used in the Netherlands with varying success. The lifespan in practice was found to vary greatly: between 1 and 5 years. This is too short a lifespan in relation to the lifespan of the layers of asphalt pavement. Ideally, the replacement of these bituminous joint transitions should take place simultaneously as the maintenance of the asphalt layers.
In the meantime, research has been carried out nationally and internationally into improving the life span of bituminous joint transitions. In Germany and Switzerland, the regulations have been shown to lead to a life span of more than 10 years. On this basis, ETAG032-3 was established in the context of EOTA in 2013.
In a competition "Silent sustainable joint transitions" held by the Dutch Directorate-General for Public Works and Water Management in the period 2007-2012, three flexible bituminous joint transitions have already been tested, two of which were ultimately found to be suitable. These have been included in the multi-choice matrix (RTD 1007-1) as concept 4.1b (anchored bituminous joint transition) and 4.1c (unanchored bituminous joint transition with stretch-spreading inlay and poured asphalt edge beams). Monitoring these joint transitions in practice over the past 8 years has shown that the desired life span is achievable with these improved joint transitions.
It is expected that the improvement in life span achieved abroad can also be realised in the Netherlands if several aspects specific to the Netherlands are taken into account:
For large parts of the Dutch main road network, the traffic intensity of 500,000 heavy vehicles per year assumed in the ETAG032-3 is insufficient. This is a factor 4 to 5 higher on the busiest main roads in the Netherlands.
On 90% of the Dutch main road network, in contrast to countries such as Germany and Switzerland, an open layer (ZOAB (zeer open asfaltbeton [very open asphalt concrete])) is used.
In the Netherlands, in contrast to countries such as Germany and Switzerland, bridges and viaducts are made on a large scale of prefabricated beams and 'floating' support systems that consist entirely of rubber supports that can be deformed all-round. Such constructions have a less favourable, high-frequency deformation behaviour under traffic load.
In Germany and Switzerland, a minimum joint mass temperature of -20 °C is assumed to test bituminous joint transitions. For the Netherlands, -15 °C is assumed, which has a favourable effect.
The present second version of RTD 1007-4 is a guideline for the development and realisation of a new generation of more durable flexible joint transitions with a minimum design life of 10-15 years and is a guideline for contractors to demonstrate that a flexible joint transition system meets the requirements as set out in the Directorate-General for Public Works and Water Management guideline RTD 1007-2.
While there is a permanent improvement of concrete pavement mixtures and pavement construction types over the last decades, the state-of-the-art joint sealing materials and joint constructions seem to stagnate on an antiquated empirical level. This status has been reaffirmed in the latest European standard. The consequences in the motorway network due to unsatisfying capability and durabilty of joint sealing systems are unacceptable. In addition, inadequate traffic performance (noise emissions, roll-over comfort) and traffic safety losses in the joint area of concrete pavements are existing challenges. These deficits and weaknesses reflect a demand for joint sealing materials and constructions whose approval requirements take functional aspects into account. Furthermore a sufficient analysis of decisive loads and a practice-oriented method to evaluate the requirements towards performance and durability is still missed. In this contribution decisive loads to German highways are analyzed. The design of test specimen for representative functional testing of joint sealing systems is discussed. The focus is on the geometry of the test specimens and the used concrete mixture. Finally, a new approach for a function-orientated test concept that considers representative load functions is presented. The potential of this approach to validate the durability and capability of various joint sealing systems is also presented using an example.
Structural health monitoring systems have been widely implemented to provide real-time continuous data support and to ensure structural safety in the context of structural integrity management. However, the quantification of the potential benefits of structural health monitoring systems has not yet attracted widespread attention. At the same time, there is an urgent need to develop strategies, such as optimizing the monitoring period, monitoring variables, and other factors, to maximize the potential benefits of structural health monitoring systems. Considering the continuity of structural health monitoring information, a framework is developed in this article to support decision-making for structural Health monitoring systems arrangement in the context of structural integrity management, which integrates the concepts of value of information and risk-based inspection planning based on an approach which utilizes a conjugate prior probability distribution for updating of the probabilistic models of structural performances based on structural health Monitoring information. An example considering fatigue degradation of steel structures is investigated to illustrate the application of the proposed framework. The considered example shows that the choice of monitoring variables, the Monitoring period, and the monitoring quality may be consistently optimized by the application of the proposed framework and approach. Finally, discussions and conclusions are provided to clarify the potential benefits of the proposed Framework with a special view to practical applications of structural health monitoring systems.
Fault detection for linear parameter varying systems under changes in the process noise covariance
(2020)
Detecting changes in the eigenstructure of linear systems is a comprehensively investigated subject. In particular, change detection methods based on hypothesis testing using Gaussian residuals have been developed previously. In such residuals, a reference model is confronted to data from the current system. In this paper, linear output-only systems depending on a varying external physical parameter are considered. These systems are driven by process noise, whose covariance may also vary between measurements. To deal with the varying parameter, an interpolation approach is pursued, where a limited number of reference models – each estimated from data measured in a reference state – are interpolated to approximate an adequate reference model for the current parameter. The problem becomes more complex when the different points of interpolation correspond to different noise conditions. Then conflicts may arise between the detection of changes in the eigenstructure due to a fault and the detection of changes due to different noise conditions. For this case, a new change detection approach is developed based on the interpolation of the eigenstructure at the reference points. The resulting approach is capable of change detection when both the external physical parameter and the process noise conditions are varying. This approach is validated on a numerical simulation of a mechanical system.
A new approach towards performance-related design and scientific evaluation of joint sealing systems
(2020)
While there is a permanent improvement of concrete pavement mixtures and pavement construction types over the last decades, the state-of-the-art joint sealing materials and joint constructions seem to stagnate on an antiquated empirical level. This status has been reaffirmed in the latest European standard.
The consequences in the motorway network due to unsatisfying capability and durability of joint sealing systems are unacceptable. In addition, inadequate traffic performance (noise emissions, roll-over comfort) and traffic safety losses in the joint area of concrete pavements are existing challenges. These deficits and weaknesses reflect a demand for joint sealing materials and constructions whose approval requirements take functional aspects into account. Furthermore a sufficient analysis of decisive loads and a practice-oriented method to evaluate the requirements towards performance and durability is still missed.
In this contribution decisive loads to German highways are analyzed. The design of test specimen for representative functional testing of joint sealing systems is discussed. The focus is on the geometry of the test specimens and the used concrete mixture. Finally, a new approach for a function-orientated test concept that considers representative load functions is presented. The potential of this approach to validate the durability and capability of various joint sealing systems is also presented using an example.