Ultra high performance concrete (UHPC) is known for its high compressive strength of more than 150 MPa and its high durability. Thermal treatment at 90°C can accelerate the strength development so that the 28-days-strength can be achieved immediately after the treatment and an additional increase up to 30 % in some cases. The reason for the strength development is an accelerated hydration of the clinker minerals and an intensified pozzolanic reaction leading to a denser microstructure.
In previous research inhomogeneities in form of a zonation after unprotected thermal treatment were observed and analysed in respect to changes in the microstructure. This zonation is defined by a different microstructure in the core compared to the outer zone in the matter of porosity, mineral phase composition and a significant change in the potassium and sulphur concentration of the zones is measurable.
To isolate different transport mechanisms responsible for these element distributions UHPC samples were thermally treated at 90 °C and the microstructure was investigated under dry conditions and after immersion in water to investigate the influence of dehydration during and rehydration after the thermal treatment on the microstructure. Through durability testing via water absorption, water vapour diffusion, permeability testing and sulfuric acid resistance transport mechanisms like diffusion, migration, capillary suction are under investigation in correlation with the microstructure analysis. For the microstructure analysis measurements with µXRF, mercury intrusion porosity, XRD and SEM were conducted.
In the last three decades, the vibrations of many floors and bridges have been measured. The contribution shows some evaluation methods, experimental results and some modelling and theoretical results. Simple evaluation methods have been developed for single and coupled floors. Two coupled beams have been measured in good agreement with the theory. A more complex coupling model has been found for a large wooden floor in a castle consisting of six floor bays which correlates well with the measurements. Damaged and intact poles have been tested by their natural frequencies and damping values, and a fair correlation between the degree of damage and the shift of the frequency. Road bridges have been analysed in detail and some examples are presented. Railway bridges and trains are studied for resonant excitation. The risk of resonance can be estimated in frequency domain by using axle-sequence spectra of the train and the natural frequencies of the bridge. A measurement example shows the amplification, but even stronger the cancellation of the subsequent axle responses. Several high-speed trains and freight trains have been analysed for their potential resonance amplification.
Die Porosität sowie die Porengrößenverteilung (PSD) eines Baustoffs sind wichtige petrophysikalische Eigenschaften, die Transportprozesse im Material beeinflussen und im direkten Zusammenhang mit der Schadensanfälligkeit stehen (Frost-Tau-Schäden, Schäden durch Salzeinträge und sauren Regen). Verfahren zur Ermittlung der Porosität stellen die Quecksilberporosimetrie (MIP), das Prinzip der Tauchwägung nach Archimedes (triple weighing method, TWM) und die Nuklear Magnetische Resonanz (NMR) dar.
Das Hauptziel dieser Arbeit ist der Vergleich der drei Methoden für die Porositätsbestimmung. Als Untersuchungsmaterial wurde Sandstein gewählt. Als Baustoff wird Sandstein trotz einer teilweise geringen Festigkeit, aber aufgrund seiner Farbvielfalt häufig für Kulturbauten, Gehwegmaterial und Fassaden eingesetzt. Sandsteine weisen zudem meist eine hohe effektive Porosität (bis zu ca. 30 %) und teilweise breite Porengrößenspektren auf, wodurch Feuchte- und Ioneneinträge begünstigt werden und zu z. B. langfristigen Verfärbungen an Sandsteinfassaden führen können.
Im Rahmen dieser Arbeit werden die Porositäten von 10 verschiedenen Sandsteinen aus Deutschland und Tschechien bestimmt. Für die Untersuchungen mittels TWM und NMR wurden für jede Sandsteinart zwei zylinderförmige Proben unter Unterdruck mit Leitungswasser aufgesättigt. Beim Vergleich der Verfahren liegt der Fokus insbesondere auf NMR und der verwendeten Gerätetechnik, die mit einer minimalen Echozeit von 50 µs ein Wasserstoffsignal in Sandsteinen aus bis zu ca. 2 nm kleine Poren erfassen kann. Darüber hinaus wird das Auflösungsvermögen von MIP und NMR bezüglich der Poren- bzw. Poreneingangsgrößen diskutiert. Für den Vergleich von NMR und MIP werden an ausgewählten Sandsteinproben ebenfalls die zusätzlich ermittelten PSD in Korrelation zueinander gebracht.
Erste Ergebnisse zeigen eine gute Korrelation von NMR- und TWM-Daten, aber teilweise starke Abweichungen zu den mit MIP bestimmten Porositäten. Ergebnisse zu den PSD zeigen teilweise nahezu identische Kurvenverläufe. Jedoch ist die Abschätzung des Umrechnungsfaktors für die NMR-Daten ohne Hinzuziehen von zusätzlichen Referenzverfahren wie Röntgen-Computer-Tomographie oder Spektral Induzierte Polarisation teilweise sehr schwierig.