In dentistry it is of great interest to achieve good sealing interzones between tooth tissue and restoration materials to avoid, e. g. secondary caries. μXRF and CμXRF are suitable to investigate the elemental composition at these interzones in respect to diffusion of elements. Synchrotron X-ray refraction radiography (SXRR) and μCT measurements deliver highly resolved structural information and make structural changes such as micro cracks within the filling and the tooth tissue visible. The presented measurements are part of the DFG funded project IXdent (Integrative X-ray techniques for chemical and structural characterizations of dental interzones.)
The depth-resolved CμXRF measurements are affected by absorption effects, making a quantitative investigation of the interzone in depth difficult. Full 3D quantification of heterogenous samples requires a complete model including dark matrix and density for each voxel. The combination of different techniques paves the way for a quantitative analysis of dental interzones.
Getting more efficient – The use of Bayesian optimization and Gaussian processes at the BAMline
(2022)
For more than 20 years, BAM is operating the BAMline at the synchrotron BESSY II in Berlin Adlershof. During this time, the complexity of the setup and the amount of data generated have multiplied. To increase the effectiveness and in preparation for BESSY III, algorithms from the field of machine learning are increasingly used.
After a short introduction to BO and GP, the first example is the automatic alignment of our double multilayer monochromator (DMM).
The second example is the optimization of measurement time in XRF scanning.
News from the BAMline
(2022)
Nowadays, teeth are not directly extracted when tooth decay occurs. Whenever treatment of the affected tooth is possible, the carious region is replaced with a suitable filling. The filling material differs according to the position and size of the cavity. Since the restoration will remain in the tooth for many years, a well adhering and sealing interface between filling and healthy tooth tissue is needed. There is continuous development of new materials, but intensive studies of this complex interface between filling and healthy tooth are still lacking. Little is known about possible diffusion of elements from dental materials into healthy tooth tissue forming a socalled interzone with specific chemical and structural properties.
The combination of different analytical X-ray methods at synchrotron radiation facilities and in the laboratory enables an extensive structural and elemental investigation of such interzones. While X-ray fluorescence techniques and X-ray absorption spectroscopy yield elemental distributions and localized chemical speciation, X-ray diffraction, refraction and computed tomography add structural information to the full 3D analysis of model and real life tooth
samples. Within two DFG funded projects, we develop adapted methodologies and investigate
micro-chemical changes in interzones which we hypothesize may lead to sclerotic dentine.
Within the DFG project ‘IXdent’, first results have been achieved on 2D µXRF and X-ray refraction radiography measurements as well as combined 3D confocal µXRF and µXCT investigations at the interface between filling and bovine tooth tissue. The benefit of multiple analytical techniques and the combination of structural and elemental analysis will be demonstrated.
Our aim is to develop a new method for full field X ray fluorescence imaging at the BAM line @ BESSY II. We will combine an energydispersive array detector for X rays with a coded aperture to get high resolution images . In coded aperture imaging , an object is projected through a mask , producing many overlapping images on the detector . The first part of the project is to perform raytracing simulations to get realistic data and to develop a reconstruction method that allows to get the Information about the investigated object out of the projected image .
Statistic process control as well as process capability demand for calibrated determination of layer thicknesses in various industries, e.g. automotive, aerospace, microelectronics manufacturing. Calibration requires well know and well characterized samples. A calibration laboratory accredited according to DIN EN ISO 17025 has the objective to distribute standards traceable to SI units to industrial laboratories for quality control of manufacturing of various products. Especially, the thickness determination of thin metallic coatings e.g. from galvanic processes or layer deposition using X-Ray Fluorescence can be significantly improved by customized calibration samples. This is essential as the measurement uncertainty directly correlates to the capability performing reliable control of processes with high yield. For calibration laboratories, the validation of results using round robins and the direct comparison to national metrology institutes is a prerequisite to demonstrate the competence to perform calibration services.
In this paper a strategy to obtain traceability and validation for thin alloy layers as well as first results are presented. The combined use of the accredited method for determination of mass per area from measurement of mass and area combined with standard free X-Ray Fluorescence as well as chemical analysis of dissolved samples with thin layers is deployed for material systems as NixZn1-x as well as NixP1-x. The obtained results are compared to reference free X-Ray Fluorescence at the BESSY II laboratories of Physikalisch-Technische Bundesanstalt. An excellent agreement of the obtained measured values as mass per unit area and alloy concentrations from the different applied methods within the measurement uncertainty was observed for NixP1-x showing the successful performed traceability of the calibration samples to SI units in combination with a validation of results by national metrology institutes and the round robin approach.
The investigation of physical properties and chemical composition generates data important for answering art-historical questions. Due to technological developments, technical diagnostics in art and culture are in ever-greater demand in such fields of transdisciplinary research. Based on one example, a collar drawing from the Berlin Diez albums, the present paper aims to give some insights into the multi-instrumental approach in the material analysis of cultural artefacts. The same methods were also applied to other drawings from the Diez Albums.
New developments in spectroscopic techniques for process control are, in general, driven by shortcomings of existing technology, for example, when sensitivity, selectivity, robustness, and so forth do not meet the demands. The perfect process analytical method would be based on a robust and easy to handle customized technique operating in real time, come without any need for calibration, that is, be an absolute method, have a professional support, and be compliant to increasing regulatory requirements. However, there are at least trends toward such an all-in-one device suitable for every purpose.
Small, low-field NMR systems equipped with permanent magnet technology have been developed and allow for quantitative analysis as on-line instruments in a production environment. Quantitative high-resolution on-line NMR spectroscopy contributes to process understanding in pilot plant and research environments.
Laser spectroscopy is a promising field in process analysis owing to its sensitivity and selectivity. Laser-induced breakdown spectroscopy LIBS is a promising field for direct in situ analysis and remote sensing. Applications of quantum-cascade lasers for process analytical applications are a promising technique. Techniques such as cavity ring-down spectroscopy (CRDS), tunable diode laser absorption spectroscopy (TDLAS), and photothermal techniques are briefly introduced.
Recent developments of new detectors have improved X-ray fluorescence analysis (XRF) for qualitative and quantitative on-line evaluation of the elementary composition of liquid or solid samples, regardless of whether compact or bulk material.
The chapter also introduces miscellaneous techniques such as ion mobility spectroscopy (IMS), microwave and dielectric spectroscopy, terahertz spectroscopy, ultrasonic acoustic spectroscopy, and other methods.