There are many different methods to characterize air-coupled ultrasonic transducers for non-destructive testing. Data sheets of various manufacturers contain information about some parameters important for the performance of transducers, but this information is not standardized, so that a comparison between probes of different manufacturers is difficult. Therefore, the German Society for Non-Destructive Testing (DGZfP) is working on a guideline to characterization of air-coupled probes.
One of the topics in this guideline is the application of thermoacoustic transducers for the characterization of receivers and another topic is the application of microphones for the characterization of transmitters. In this presentation we compare various characterization methods with the particular focus on the characterization of thermoacoustic transducers using an optical microphone. Both thermoacoustic transmitters and optical microphones have a very large bandwidth compared to conventional air-coupled transducers, but their spectrum is not entirely linear, which needs to be taken into account if they are applied as reference transducers.
Air-coupled ultrasonic testing (ACUT) has experienced rapid growth within the last years. It is especially well suited to inspection of lightweight structures consisting of composite materials and adhesive joints. Uniform coupling and easy maintenance are its advantages compared to contact technique. However, the impedance mismatch between the transducer and air poses a major challenge to the development of ACUT transducers. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers. Their fabrication is difficult in handling and their signal-to-noise ratio sometimes not sufficient for various testing requirements. However, there are several innovative approaches using other materials and other physical principles to transmit and receive an ultrasonic pulse. We present a review of the latest advances in research on air-coupled transducers for non-destructive testing, including previously unpublished results. We recognize two major directions as most promising: ferroelectrets and thermoacoustic transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties. Their small acoustic impedance is matched to air better than matching layers applied in conventional air-coupled transducers. Applying bias voltage to a ferroelectret receiver is the latest development in this field, which increased the received signal by 12 to 15 dB. Thermoacoustic transducers use heat to initiate an ultrasonic wave, acting as transmitters. The working principle is known from nature as thunder and lightning: thermal energy of an electrically heated material, which can also be air, is converted into acoustic energy. Some thermoacoustic transmitters consist of a conductive layer with a thickness in the nanometer range deposited on a solid substrate. Another possibility is to use an electric spark. For the first time, measurements of the sound field of an electric spark up to 500 kHz were performed. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing.
Air-coupled ultrasound (ACU) is increasingly used for automated and contactless inspection of large-scale composite structures as well as for non-destructive testing (NDT) of water-sensitive or porous materials. The major challenge to overcome using ACU in NDT is the enormous loss of ultrasonic energy at each solid-air interface caused by the high acoustic impedance mismatch. Resonant low-frequency piezoceramic transducers are specially designed to achieve high sound pressure levels. For an expanded use of this technique, however, the spatial resolution needs to be increased.
Recent studies of our collaborative research group demonstrated the successful application of a resonance-free, highly sensitive receiver that uses a Fabry-Pérot etalon instead of piezoceramic materials or membranes. However, to reach the full potential of this broadband small-aperture optical microphone, novel transmitter concepts have to be developed and evaluated for advanced NDT applications.
Different types of transmitter were tested in combination with the optical microphone acting as receiver and they were compared to conventional piezoceramic transducers in through-transmission mode. Monolithic carbon fiber-reinforced plastics (CFRP) and CFRP sandwich structures containing different defect types were inspected. Presented results are processed as C-scan images and further evaluated for spatial resolution, signal-to-noise ratio and sensitivity of each measurement setup. Novel transmitter concepts, such as ferroelectret and thermoacoustic emitters, show promising findings with a considerably improved time and spatial resolution for ACU-NDT.
Air-coupled ultrasonic testing (ACUT) has experienced rapid growth within the last years. It is especially well suited to inspection of lightweight structures consisting of composite materials and adhesive joints. Uniform coupling and easy maintenance are its advantages compared to contact technique. However, the impedance mismatch between the transducer and air poses a major challenge to the development of ACUT transducers. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers. Their fabrication is difficult in handling and their signal-to-noise ratio sometimes not sufficient for various testing requirements. However, there are several innovative approaches using other materials and other physical principles to transmit and receive an ultrasonic pulse. We present a review of the latest advances in research on air-coupled transducers for non-destructive testing, including previously unpublished results. We recognize two major directions as most promising: ferroelectrets and thermoacoustic transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties. Their small acoustic impedance is matched to air better than matching layers applied in conventional air-coupled transducers. Applying bias voltage to a ferroelectret receiver is the latest development in this field, which increased the received signal by 12 to 15 dB. Thermoacoustic transducers use heat to initiate an ultrasonic wave, acting as transmitters. The working principle is known from nature as thunder and lightning: thermal energy of an electrically heated material, which can also be air, is converted into acoustic energy. Some thermoacoustic transmitters consist of a conductive layer with a thickness in the nanometer range deposited on a solid substrate. Another possibility is to use an electric spark. For the first time, measurements of the sound field of an electric spark up to 500 kHz were performed. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing.
Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio.
Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio.
Luftgekoppelte Ultraschallwandler werden für die bildgebende Prüfung von Klebeverbindungen und Verbundwerkstoffen eingesetzt. Nach dem heutigen Stand der Technik wird die Prüfung in Durchschallung durchgeführt, d.h. der Prüfling befindet sich zwischen dem Sender und dem Empfänger. Allerdings erlauben komplexere Strukturen wie z.B. Teile einer PKW-Karosserie, nur einen einseitigen Zugang. Für die Prüfung solcher Bauteile sind Wandler von hoher Bandbreite von Vorteil. Thermoakustische Wechselwirkung, wobei thermische Energie einer elektrisch geheizten Elektrode in akustische umgewandelt wird, öffnet die Möglichkeit, extrem breitbandige Pulse zu erzeugen.
In unserem Beitrag werden verschiedene thermoakustische Sender vorgestellt. Die meisten bestehen aus einer elektrisch leitenden Schicht auf einem festen Substrat. Der erste Typ ist ein Sender mit einer Elektrode aus Indium-Zinn-Oxid auf Glas-Substrat kombiniert mit einem Laser-Doppler-Vibrometer als Empfänger. Diese Kombination ermöglicht extrem breitbandige Signale. Der zweite Typ kombiniert thermoakustische Emission mit piezoelektrischem Empfang. Dieser Typ besteht aus einer Titan-Elektrode auf geladenem zellulärem Polypropylen, das als piezoelektrischer Empfänger dient. Zelluläres Polypropylen ist mit einem Elastizitätsmodul von ca. 1 MPa bei 250 kHz an die Luft sehr gut angepasst. Der dritte Wandlertyp ist ein Wandler mit elektrostatischen Gasentladung unter Atmosphärendruck.
Mit dem fokussierenden thermoakustischen Sender (Typ 1) und einem Polypropylen-Empfänger ist eine Durchschallung einer 4 mm dicken Platte aus carbonfaserverstärktem Kunststoff gelungen. Künstliche Delaminationen mit der Größe 1 mm wurden detektiert. Derselbe Sender kombiniert mit einem Laser-Doppler-Vibrometer als Empfänger wurden für die Prüfung von einem Testkörper aus PMMA mit einseitigem Zugang eingesetzt. Der Wandler bestehend aus einem thermoakustischen Sender auf einem Polypropylen-Empfänger (Typ 2) wurde für die Profilvermessung eines Stufenkeils eingesetzt. Dabei wurden Flachbodenbohrungen mit einem Durchmesser 1 mm abgebildet. Mit diesen beiden Sendern wurde ein Schalldruckpegel über 140dB im Fokus gemessen. Der Wandler mit der Funkenentladung (Typ 3) wurde für die Charakterisierung von Luftultraschallwandlern eingesetzt. Auf Basis dieses Entladungstyps wurde ein Schalldruckpegel über 160dB an einem Abstand von 150 mm gemessen, was deutlich über dem Schallpegel aller bekannten Luftultraschall-Wandler liegt. Die größte Bandbreite von deutlich über 100% der Mittenfrequenz wurde mit dem Wandler Typ 1 erreicht. So große Bandbreiten ermöglichen neue Anwendungen für Luftultraschallwandler, insbesondere wenn kombiniert mit Signalverarbeitungsalgorithmen.
Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers.
Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers.