Certification report for the reference materials ERM-AE102a, -AE104a, -AE120, -AE121 and -AE122
(2010)
Isotope reference materials are essential to enable reliable and comparable isotope data. Besides the correction of mass fractionation or mass discrimination isotope reference materials are indispensible for validation and quality control of analytical procedures. This article describes the production and certification of a set of five isotope reference materials ERM-AE102a, 104a, AE120, 121 and 122, for boron isotope analysis. The isotopic composition of all materials has been adjusted by mixing boron mother solutions enriched in 10B or 11B with a boron mother solution having natural-like isotopic composition under full gravimetric control. All mother solutions have been analysed for their boron mass fraction as well as their boron isotopic composition by TIMS using IDMS as calibration technique. For all five reference materials the isotopic composition obtained on the basis of the gravimetric data agrees very well with the isotopic composition obtained from different TIMS techniques. Performed stability and homogeneity studies show no significant influence on the isotopic composition as well as on the related uncertainties.
The certified isotope abundances for 10B are 0.29995 (27) for ERM-AE102a and 0.31488 (28) for ERM-AE104a. The certified δ11B values are -20.2 (6) ‰ for ERM-AE120, 19.9(6) ‰ for ERM-AE121 and 39.7 (6) ‰ for ERM-AE122.
Together with the formerly certified ERM-AE101 and -AE103 a unique set of seven certified reference materials (CRM) for boron isotope analysis is now available from BAM.
Analytische Methoden zur Feststellung der Herkunft eines Baustoffes sind bislang kaum entwickelt worden. In Deutschland gibt es eine Reihe von Kalkiagerstätten, die in unterschiedlichen geologischen Formationen Kalk oder Dolomit enthalten. Das unterschiedliche geologische Alter von Kalken sowie die ursprüngliche mineralische Zusammensetzung und die geologische Historie spiegeln sich im 87Sr/88Sr-lsotopenverhältnis weder. Mittels der Thermionen-Massenspektrometrie kann dieses Verhältnis ermittelt und somit zur Herkunftsbestimmung eines Kalkes herangezogen werden.
Die Industrie nutzt die Borisotopenanalytik in nukleartechnischen Anwendungen. Umwelt- und Geowissenschaften identifizieren anhand der Borisotopenverhältnisse Kontaminationsquellen und charakterisieren Mischungs- und Fraktionsprozesse. In der Lebensmittelanalytik dient der Parameter dazu, Herkunft und Anbauweise von Obst und Gemüse herauszufinden. Seit kurzem gibt es dafür ein validiertes Verfahren und erste Referenzdaten.
The quantitative analysis of toxic metals in plastics is very important for different sectors of industry and daily life. Many routine procedures have been established based on X-ray fluorescence or inductively coupled plasma atomic emission spectrometry. However, all of them require suitable reference materials to calibrate or validate. These reference materials ideally are being certified by reference procedures. The development of such reference procedures for sulfur and the four toxic elements cadmium, chromium, mercury and lead in plastics is described here. The procedures are based on double isotope dilution mass spectrometry including analyte–matrix separation. The applied mass spectrometric techniques are thermal ionization mass spectrometry as well as inductively coupled plasma mass spectrometry. Memory effects of mercury and dissolution of chromium(III) oxide have been considered especially. The expanded uncertainties have been improved from the percent range down to the per mill range during the development of the procedure from the early analysis of BCR-680/681 to the recent analysis of CCQM-P106. With the fully developed procedures expanded uncertainties (k = 2) between 0.1 and 0.4% for cadmium, chromium, lead and sulfur and around 1% for mercury can be achieved. The so developed procedures have been successfully applied to the certification of reference materials as well as to intercomparisons organized by CCQM.
Isotope reference materials are essential to enable reliable and comparable isotope data. This article reviews the work in this field within the past years. The focus is on all stable elements, except for classical stable isotopes (H, C, N, O, S) and for radioactive elements. Currently available isotope reference materials are listed. The limitations of synthetic isotope mixtures being used to characterize these materials are discussed, as well as the limitations of the isotope reference materials, such as uncertainty and homogeneity. The needs for present research on isotope variations are being considered and are compared to the limitations of current isotope reference materials. This disagreement between both can only be solved by providing isotope reference materials defining a δ-scale for each element of interest. Such materials should be provided with additional data on isotope abundances whenever possible. As an outlook a possible outline for a new program on isotope reference materials is discussed.
The strontium isotope composition of food samples has been successfully used to trace the provenance of both herbal and animal agricultural products. Adequately accurate and precise 87Sr/86Sr ratios, however, are key to unravel environmental and anthropogenic strontium contributions of specific growing areas. In a recently published analytical method in Food Chemistry by Choi et al. (2008) a demonstrably inadequate protocol for the determination of 87Sr/86Sr ratios of ginseng is presented. Based on well established geological and analytical fundamentals the 87Sr/86Sr ratios presented by Choi et al. (2008) are too inaccurate and imprecise to be used to trace the origin of the ginseng. Appropriate wet chemical separation techniques and mass spectrometric instrumentation enables the generation of 87Sr/86Sr data with very low expanded uncertainties (<0.05%, k = 2). Those high quality data allow the identification of even small strontium contributions of source reservoirs or physical and anthropogenic processes if diagnostic isotope compositions are present.
A comparison of high accuracy methods for the analysis of total sulfur in gas oils by three metrology institutes is described. The work contains a comparison of three different aspects of the analysis: sample digestion, instrumental measurement and isotope dilution strategies.
Thermal ionisation mass spectrometry (TIMS) in combination with high pressure asher (HPA) or Carius tube digestion has traditionally been used for such high accuracy analysis. However, this paper demonstrates that the faster, less laborious technique of ICP-MS in combination with microwave digestion is equally capable. Results from the comparison experiments show excellent agreement for fuel samples containing sulfur concentrations in the range 11200 µg g-1. This excellent agreement across the different sample preparation, measurement and isotope dilution techniques has been exploited in the certification of two new diesel fuel reference materials.
The present work describes the development of an existing TIMS procedure to a reference procedure for low sulfur concentration measurements in fossil fuels. With this enhanced procedure SI-traceable sulfur mass fractions below 10 mg kg-1 can be obtained. The achieved detection limit is approximately 0.2 mg kg-1. The procedure was validated by certified reference materials. The procedure was already applied to candidate reference materials and to samples analysed within projects of the Comité Consultatif pour la Quantité de Matière CCQM.
Additionally the influence of the isotopic composition on the results and its corresponding uncertainty was studied. Reference data published in the literature on the isotopic composition of sulfur were assessed.
The ?- branching ratio of 64Cu was determined by investigating the resulting decay products in copper doped by neutron transmutation. The numbers of 64Zn and 64Ni atoms were analyzed using isotope dilution analysis combined with thermal ionization mass spectrometry. A ?- branching ratio of (38.06±0.30)% was obtained, which agrees with the study of Kawada (Appl. Radiat. Isot. 37 (1) (1986) 7) to a higher accuracy. However, our result differs from the value cited in the NUDAT database of (39.0±0.3)%.