Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Spectroscopy (64) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (21)
- 1.9 Chemische und optische Sensorik (10)
- 6 Materialchemie (10)
- 8 Zerstörungsfreie Prüfung (10)
- 1.2 Biophotonik (7)
- 4 Material und Umwelt (5)
- 6.3 Strukturanalytik (5)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (5)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 4.5 Kunst- und Kulturgutanalyse (3)
Eingeladener Vortrag
- nein (12)
This technical note highlights the fact that CF-LIBS algorithms work in mole fractions, while results of spectrochemical analysis are usually reported in mass fractions or mass percent. Ignoring this difference and not converting mole fractions to mass fractions can lead to errors in reported concentrations determined by the CF-LIBS method and inadequate comparison of these concentrations with certified concentrations. Here, the key points of the CF-LIBS algorithm are reproduced and the formulae for converting a mole fraction to a mass fraction and vice versa are given. Several numerical examples are also given, which show that the greater the difference between the molar mass of an individual element in a sample and the average molar mass, the greater the discrepancy between the mole and mass fractions.
SWIR luminescent nanomaterials – key chemical parameters for bright probes for in vivo bioimaging
(2024)
A current challenge for studying physio-pathological phenomena and diseaserelated processes in living organisms with non-invasive optical bioimaging is the development of bright optical reporters that enable deep tissue penetration, a high detection sensitivity, and a high spatial and temporal resolution. The focus of this project are nanomaterials, which absorb and emit in the shortwave infrared (SWIR) between ~900–2500 nm where scattering, absorption, and autofluorescence of the tissue are strongly reduced compared to the visible and NIR.
Four donor-acceptor boron difluoride complexes based on the carbazole electron donor and the [1,3,5,2]oxadiazaborinino[3,4-a][1,8]naphthyridine acceptor were designed, synthesized, and systematically spectroscopically investigated in solutions, in the solid states, and dye-doped polymer films. The dyes exhibit an intense blue to red solid-state emission with photoluminescence quantum yields of up to 56% in pure dye samples and 86% in poly(methyl methacrylate) films. All boron complexes show aggregation-induced emission and reversible mechanofluorochromism. The optical properties of these dyes and their solid state luminescence can be tuned by substitution pattern, i.e., the substituents at the naphthyridine unit. Exchange of CH3- for CF3-groups does not only increase the intramolecular charge transfer character, but also provides a crystallization-induced emission enhancement.
The development of new fluorescent organic probes effective in the NIR-II region is currently a fast-growing field and represents a challenge in the domain of medical imaging. In this study, we have designed and synthesized an innovative series of aza-boron dipyrromethenes emitting in the NIR-II region. We have investigated the effect of different water-solubilizing groups not only on the photophysical properties of the compounds but also on their in vitro and in vivo performance after bioconjugation to the antibody trastuzumab. Remarkably, we discovered that the most lipophilic compound unexpectedly displayed the most favorable in vivo properties after bioconjugation. This underlines the profound influence that the fluorophore functionalization approach can have on the efficiency of the resulting imaging agent.
The ink analysis protocol developed through cooperation between the Bundesanstalt für Materialforschung und -prüfung in Berlin and the Centre for the Study of Manuscript Cultures at the University of Hamburg involves the use of imaging techniques for ink screening, followed by spectroscopic analysis. In our presentation, we will begin by briefly reviewing the history of writing inks and discussing the three main categories: carbon-based inks, plant, and iron-gall inks. We will address their chronology, precursors, and mixed forms, as well as the features that allow for their identification. Then, we will present the techniques we use in ink analysis, whereby we would like to highlight the limitations, advantages, and disadvantages of each approach. Finally, we will discuss the new mass-spectrometric method based on micro-sampling and using atmospheric solid analysis probe (ASAP).
The Boltzmann plot method is widely used to determine the temperature of laser induced plasma. It involves the use of individual lines that are not easy to find in complex spectra and/or in the spectral range available. If the number of such lines is not enough to build a reliable Boltzmann plot, overlapping lines are often used, which are separated by software. However, line separation is a rather imprecise procedure, which, in addition, requires significant computational costs. This study proposes an extension of the Boltzmann plot method that allows a specific group of unresolved lines to be included in a Boltzmann plot without the need to separate them. This group of lines are multiplets, lines of the same element with similar upper and lower transition states. The multiplet lines along with the individual lines are included in the algorithm, which also includes a correction for self-absorption and is used to determine the plasma temperature. The algorithm is tested on synthetic spectra which are consistent with the model of a homogeneous isothermal plasma in local thermodynamic equilibrium and is shown to be superior to the standard Boltzmann plot method both in more accurate determination of the plasma temperature and in a significant reduction in the computational time. The advantages and disadvantages of the method are discussed in the context of its applications in laser induced breakdown spectroscopy.
The aim of this chapter is to give an overview of basic and advanced state-of-the-art microstructural and spectroscopic analytics to investigate inorganic material corrosion in the context of biochemically aggressive sewers. The chapter covers optical methods, electron beam, X-ray and neutron techniques (SEM, MLA, XRF, XRD, CT, Neutron radiography and tomography), and spectroscopic methods (MAS-NMR, FT-IR, and Raman). For each technique, a short section on the fundamental scientific background of the method precedes and examples of data output from the latter in respect to the corrosion of cementitious materials including reinforced concrete is presented.
This study will present a new approach to distinguishing writing inks that have the same elemental compositions and visual appearances. The approach is based on displaying the intensity of elemental distributions as heat maps that represent data recorded with a scanning μX-ray fluorescence spectrometer. The heat maps present the data so as to facilitate digitally identifying and distinguishing between inks used to produce, correct, and reink two medieval Torah scrolls. As ritual objects, Torah scrolls had to be written in accordance with exacting standards that evolved over time. This requirement led to successive stages of modifications, sometimes over centuries. Both vitriolic and non-vitriolic inks used to modify Torah scrolls can be visually identical to each other. Furthermore, different non-vitriolic inks usually have an identical elemental composition. The solid material analysis evidence and its presentation as heat maps made it possible to discriminate between original and altered portions of text that in some cases would have been impossible. Our interdisciplinary work brought together conservation, material science, paleog-raphy, and philology to enable the identification of complex stratigraphy in multiple stages of production, correction, and reinking. ©2 0 2 2 Published by Elsevier Masson SAS.
Evaluation of marker materials and spectroscopic methods for tracer-based sorting of plastic wastes
(2022)
Plastics are a ubiquitous material with good mechanical, chemical and thermal properties, and are used in all industrial sectors. Large quantities, widespread use, and insufficient management of plastic wastes lead to low recycling rates. The key challenge in recycling plastic waste is achieving a higher degree of homogeneity between the different polymer material streams. Modern waste sorting plants use automated sensor-based sorting systems capable to sort out commodity plastics, while many engineering plastics, such as polyoxymethylene (POM), will end up in mixed waste streams and are therefore not recycled. A novel approach to increasing recycling rates is tracer-based sorting (TBS), which uses a traceable plastic additive or marker that enables or enhances polymer type identification based on the tracer’s unique fingerprint (e.g., fluorescence). With future TBS applications in mind, we have summarized the literature and assessed TBS techniques and spectroscopic detection methods. Furthermore, a comprehensive list of potential tracer substances suitable for thermoplastics was derived from the literature. We also derived a set of criteria to select the most promising tracer candidates (3 out of 80) based on their material properties, toxicity profiles, and detectability that could be applied to enable the circularity of, for example, POM or other thermoplastics.