Filtern
Dokumenttyp
- Posterpräsentation (6)
- Zeitschriftenartikel (3)
- Vortrag (1)
- Forschungsbericht (1)
Sprache
- Englisch (11)
Schlagworte
- Sialic acid (11) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
Sialic acid (SA) is a monosaccharide usually linked to the terminus of glycan chains on the cell surface. It plays a crucial role in many biological processes, and hypersialylation is a common feature in cancer. Lectins are widely used to analyze the cell surface expression of SA.
However, these protein molecules are usually expensive and easily denatured, which calls for the development of alternative glycan-specific receptors and cell imaging technologies. In this study, SA-imprinted fluorescent core-shell molecularly imprinted polymer particles (SA-MIPs) were employed to recognize SA on the cell surface of cancer cell lines. The SA-MIPs improved suspensibility and scattering properties compared with previously used core-shell SA-MIPs. Although SA-imprinting was performed using SA without preference for the alpha-2,3- and alpha-2,6-SA forms, we screened the cancer cell lines analyzed using the lectins Maackia Amurensis Lectin I (MAL I, alpha-2,3-SA) and Sambucus Nigra Lectin (SNA, alpha-2,6-SA). Our results show that the selected cancer cell lines in this study presented a varied binding behavior with the SA-MIPs. The binding pattern of the lectins was also demonstrated. Moreover, two different pentavalent SA conjugates were used to inhibit the binding of the SA-MIPs to breast, skin, and lung cancer cell lines, demonstrating the specificity of the SA-MIPs in both flow cytometry and confocal fluorescence microscopy. We concluded that the synthesized SA-MIPs might be a powerful future tool in the diagnostic analysis of various cancer cells.
Inhibition of respiratory viruses is one of the most urgent topics as underlined by different pandemics in the last two decades. This impels the development of new materials for binding and incapacitation of the viruses. In this work, we have demonstrated that an optimal deployment of influenza A virus (IAV) targeting ligand sialic acid (SA) on a flexible 2D platform enables its binding and wrapping around IAV particles. A series of 2D sialylated platforms consisting graphene and polyglycerol are prepared with different degrees of SA functionalization around 10%, 30%, and 90% named as G-PG-SAL, G-PG-SAM, and G-PG-SAH, respectively. The cryo-electron tomography (Cryo-ET) analysis has proved wrapping of IAV particles by G-PG-SAM.
A confocal-based colocalization assay established for these materials has offered the comparison of binding potential of sialylated and non-sialylated nanoplatforms for IAV. With this method, we have estimated the binding potential of the G-PG-SAM and G-PG-SAH sheets for IAV particles around 50 and 20 times higher than the control sheets, respectively, whereas the low functionalized G-PG-SAL have not shown any significant colocalization value.
Moreover, optimized G-PG-SAM exhibits high potency to block IAV from
binding with the MDCK cells.
Glycoproteins are abundant on the cell surface of mammals, providing structural support, modulating cell Membrane properties, and acting as signaling agents. Variation of glycosylation patterns has been found to indicate various disease states, including cell malignancy. Sialic acid (SA) is present as a terminating group on cell-surface glycans, and its overexpression has been linked to several types of cancer. Detection of SA on the cell surface is therefore critical for detection of cancer in its early stages. In this work, a fluorescent molecularly imprinted polymer layer targeting SA was synthesized on the surface of silica-coated polystyrene (PS) particles. Compared to previous works, a PS core supplies a lighter, lower-density support for improved suspension stability and scattering properties. Moreover, their smaller size provides a higher surface-area-to-volume ratio for binding. The incorporation of a fluorescent monomer in the MIP shell allowed for simple and rapid determination of binding specificity in polar media due to a deprotonation−reprotonation interaction mechanism between the fluorescent monomer and SA, which led to spectral changes.
Upon titration of the MIP particles with SA in suspension, an increase in fluorescence emission of the particles was observed, with the MIP particles binding SA more selectively compared to the nonimprinted polymer (NIP) control particles. In cell staining experiments performed by flow cytometry, the binding behavior of the MIP particles compared favorably with that of SA-binding lectins. NIPs prepared with a “dummy” template served as a better negative control in cell binding assays due to the favorable inward orientation of template-binding functional groups in the polymer shell, which reduced nonspecific binding. The results show that fluorescent MIPs targeting SA are a promising tool for in vitro fluorescence staining of cancerous cells and for future diagnosis of cancer at early stages.
Design, Synthesis and Characterization of Fluorescent MIP Particles for Labelling of Malignant Cells
(2020)
Cancer is a leading cause of death worldwide, and its early detection and resultant treatment contributes significantly to patient recovery and survival. Detection is currently based on magnetic resonance imaging and computed tomography, methods that are expensive, while processing of the results is time-consuming1. There is a need for low-cost cancer detection techniques that give conclusive results in the shortest time possible. When equipped with a reporter function, molecularly imprinted polymers (MIPs) targeting tumor markers on cancerous cells may provide a cheaper solution for imaging-based cancer detection. Thin MIP layers immobilized on particle platforms are ideal in this regard, because a fluorescence reporter can be integrated into the particle core and/or MIP shell and such core/shell nanoparticles show faster response times and increased selectivity in comparison to bulk MIPs.
Changes in sialylation patterns of cell surface glycans indicate malignancy2. Here, we present the design, synthesis and characterization of MIPs that target sialic acid-terminated glycans (SA MIPs), prepared as a thin layer on a polystyrene core/silica shell nanoparticle platform. The MIP particles contain fluorescent emitters and can be applied in fluorescence imaging of malignant tumors. Dynamic light scattering (DLS) and transmission electron microscopy (TEM) are used for structural characterization. Binding capacity of the MIPs to target glycans and competing sugars is also evaluated and compared to that of the corresponding non-imprinted polymer particles (NIP).
Cancer is a leading cause of death worldwide, and its early detection and resultant treatment contributes significantly to patient recovery and survival. Detection is currently based on magnetic resonance imaging and computed tomography, methods that are expensive, while processing of the results is time-consuming1. There is a need for low-cost cancer detection techniques that give conclusive results in the shortest time possible. When equipped with a reporter function, molecularly imprinted polymers (MIPs) targeting tumor markers on cancerous cells may provide a cheaper solution for imaging-based cancer detection. Thin MIP layers immobilized on particle platforms are ideal in this regard, because a fluorescence reporter can be integrated into the particle core and/or MIP shell and such core/shell nanoparticles show faster response times and increased selectivity in comparison to bulk MIPs.
Changes in sialylation patterns of cell surface glycans indicate malignancy2. Here, we present the development of MIPs that target sialic acid-terminated glycans (SA MIPs), prepared as a thin layer on a polystyrene core/silica shell nanoparticle platform. The MIP particles contain fluorescent emitters and can be applied in fluorescence imaging of malignant tumors. Dynamic light scattering (DLS) and transmission electron microscopy (TEM) are used for structural characterization. Binding capacity of the MIPs to target glycans and competing sugars is also evaluated and compared to that of the corresponding non-imprinted polymer particles (NIP).
Digital holographic cytometry (DHC) is a state-of-the-art quantitative Phase imaging (QPI) method that permits time-lapse imaging of cells without induced cellular toxicity. DHC platforms equipped with semi-automated image segmentation and analysis software packages for assessing cell behavior are commercially available. In this study we investigate the possible uptake of nanoprobes in macrophages in vitro over time.
Sialic acid (SA) is a cell surface glycan, which has been found to be upregulated on more aggressive cancers. Therefore, there is a great interest in developing methods for detection of SA on a great interest in developing methods for detection of SA o on cancer cells. We are screening SA on cell lines by fluorescent molecularly imprinted polymers, SA fluorescent molecularly imprinted polymers, SA fluorescent molecularly imprinted polymers, SA fluorescent molecularly imprinted polymers, SA fluorescent molecularly imprinted polymers, SA fluorescent molecularly imprinted polymers, SA -MIPs. Quantitative phase imaging (QPI) is a digital holographic technique. Various cellular parameters can be visualized and calculated from the particular hologram, including individual cell area, thickness, volume and population confluence and cell counts. The aim was to investigate the possible uptake of SA in macrophage cell lines in in vitro cell cultures and check if they affected the cell.
Cancer is the second leading cause of death globally according to the WHO 2018. Lung, prostate, colorectal, stomach and liver cancer are the most common types of cancer in men, while breast, colorectal, lung, cervix and thyroid cancer are the most common among women. Sialic acid (SA) plays an important role in a variety of biological processes in cells. Tumor cells express high levels of SA, which is often associated with poor prognosis due to increased invasive potential. In this study, we have performed a screening of SA-MIPs binding to different cancer cell lines. The overall aim is to use the SA-MIPs for detection of tumor cells, analyzed by flow cytometry and fluorescence microscopy. To confirm the levels of SA expression on the investigated cell lines, we started out by analyzing the binding of the lectins MAL I and SNA. The staining pattern of the two lectins binding to either α-2,3 or α-2,6 linkage SA, respectively, was compared with the staining pattern of the SA-MIPs. We show that the different cell types analyzed have a varying pattern of SA-MIP binding. The comparison with lectin binding will be further evaluated.
Sialic acid (SA) is a cell surface glycan, which has a strong role in many cell activities including differentiation, proliferation, and the immune response. The amount of SA has been found to be correlated with cancer, with an upregulation on more aggressive cancers. Therefore, there is great interest in developing methods for detection of SA on cancer cells. We are screening SA on cancer cell lines by using fluorescent molecularly imprinted polymers, SA-MIPs.Macrophages, which evolve from mono-cytes, are well known for their extraordinary ability to phagocytose foreign objects. This could lead to the hypothesis that the SA-MIPs can be recognized by macrophages as foreign object; thus leading to internalization and potential degradation. We have discovered that SA-MIPs can be detected after incubation with the RAW macrophage cells, with increasing fluorescence over time. The microscopy analysis shows that the RAW cells ingest the SA-MIP particles. This information is important when planning to use SA-MIPs in future in vivo applications.
Sialic acid (SA) is a cell surface glycan, which has a decisive role in many cell activities including differentiation, proliferation, and the immune response. The amount of SA has been found to correlate with cancer, with an upregulation on more aggressive cancers. Therefore, there is a great interest in developing methods for detection of SA on cancer cells. We are screening SA on cancer cell lines by using fluorescent molecularly imprinted polymers, SA-MIPs. Macrophages, which evolve from mono-cytes, are well known for their extraordinary ability to phagocytose foreign objects. This could lead to the hypothesis that the SA-MIPs can be recognized by macrophages as foreign object; thus leading to internalization and potentially degradation.
We have demonstrated that SA-MIPs can be detected after incubation with the RAW macrophage cells, with increasing fluorescence over time. The microscopy analysis shows that the RAW cells ingest the SA-MIP particles. This information is important when planning to use SA-MIPs in future in vivo applications.