PileInspect
(2019)
The EC funded project PileInspect (2013-2016) has tried to improve the traditional low strain pile integrity test by using a shaker instead of a hamm and sophisticated higher order spectra analysis methods to provide automated, reliable interpretation. However, the results, even if promising, have not seen full validation yet. A second module, providing depth information by regularized deconvolution, was developed and tested successfully, but doesn't deliver additional information compared tomteh traditioanl test.
In this study, an Impulse Response Function analysis of pile response to sine-sweep excitation by a low cost, portable Shaker was used to identify defects in piles. In straightforward impact-echo methods, echoes from the pile toe and defects are visible in the time domain measurements. However, these echoes are not present in the time domain records of piles subjected to sine-sweep excitations, due to interactions between the input and output signals. For this reason, the impulse response function in the time domain has been calculated and is able to identify the echoes from pile impedance changes. The proposed methodology has been evaluated both numerically and experimentally. A one-dimensional pile-soil interaction system was developed, and a finite difference method used to calculate the pile response to sine-sweep excitation. The numerical simulations indicate that impulse response measurements with a synthesized logarithmic, sine-sweep excitation could be an effective tool for detecting defects in piles. The methodology was further tested with field trials on 6 cast in situ concrete test piles including 1 intact pile and 5 defective piles subjected to sine-sweep excitations by a shaker. In 5 of the 6 cases the echoes from the pile toe could be identified in the deconvoluted waveforms—the impulse Response functions. Damage detection is more difficult and dependent on the selection of the optimal regularization parameter. Further research and optimization of the deconvolution process is needed to evaluate the effectiveness compared to standard pile integrity testing methods.
Low strain pile integrity testing is an established method in QA of foundation piles. The technique is very effective and well accepted for larger flaws and length determination. It is part of standards and recommendations. Challenges exist for more complicated structures (e. g. pile walls, diaphragm walls, and pile under structures) and small flaws. Interpretation is subjective in many cases. Possible solutions, e.g. the use of vibrators instead of a hammer or application of several sensors instead of one have been proposed decades ago, but not used much in practice. In several projects we are working on the extension and optimizations of these ideas, based on input from other engineering disciplines. In the frame of the project PileInspect we are working with an international consortium on the use of vibrators instead of a hand held hammer. This allows the full control of input signals as well as the use of (semi)automatic classification routines from machine diagnosis. At BAM we are using a low cost vibrator and deconvolution routines to improve the results of classical low strain testing. In another project we are working on multichannel measurements with sensor placement along the pile axis. This can be used to determine the travel direction of certain waves (downwards or upwards) to improve the interpretation of measurements on piles below constructions or pile walls. The use of ideas adapted from geophysics („vertical seismic profiling“) are helpful. Both concepts are proven by simulations results and first field tests.
Fatigue testing in the VHCF ränge requires testing machines with increased frequencies. However, application of energy-saving resonance testing leads to a linkage between test frequency and specimen Parameters. The frequency ränge and the available forces of the testing machine are limiting possible specimen dimensions.
Electrodynamic shakers combine test frequencies up to 4000 Hz with forces in the kN range. Thus, a relatively wide range of tests is possible which allows studying the influence of specimen size on VHCF behaviour.
Electrodynamic shakers as well as the respective Computer control Systems and Vibration measurement techniques are well established in scientific and technical applications. We present results of a first study of VHCF testing on electrodynamic shakers conducted at BAM. Test frequency, specimen size and stress levels have been varied. One goal is to balance the needs of materials testing with the Standard test Systems of environmental Simulation to provide a powerful and flexible tool for very high cycle fatigue testing. Further investigation to optimize the technique is required.