Radiography benchmark 2014
(2015)
The purpose of the 2014 WFNDEC RT benchmark study was to compare predictions of various models of radiographic techniques, in particular those that predict the contribution of scattered radiation. All calculations were carried out for homogenous materials and a mono-energetic X-ray point source in the energy range between 100 keV and 10 MeV. The calculations were to include the best physics approach available considering electron binding effects. Secondary effects like X-ray fluorescence and bremsstrahlung production were to be taken into account if possible. The problem to be considered had two parts. Part I examined the spectrum and the spatial distribution of radiation behind a single iron plate. Part II considered two equally sized plates, made of iron and aluminum respectively, only evaluating the spatial distribution. Here we present the results of above benchmark study, comparing them to MCNP as the assumed reference model. The possible origins of the observed deviations are discussed.
The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.
Correctly modeling the continuous photon spectrum of X-ray tubes requires detailed knowledge of the probability distribution of electron properties at the time of X-ray photon creation, in particular electron energy, depth within the target, and direction of movement. Semi-analytical X-ray spectrum models frequently assume a very simplified or even uniform distribution of electron direction. In the case of thick targets and small deviations from normal incidence this is a useful approximation. For thin targets or large deviations from normal incidence the correct distribution of electron directions becomes more important. As calculation speed is an important aspect of semi-analytical models compared to Monte Carlo simulations, fast evaluation of the distribution of electron properties is highly desirable. The approach presented here numerically evaluates the evolution of a discrete probability distribution of electron properties due to single electron scatter interactions within a plane target. This allows capturing the important aspects of the electron distribution while achieving runtimes of a few seconds up to a minute on a standard office PC.