Engineered and tailored nanomaterials (NM) are of great interest in the life and material sciences, as they can be used, e.g., as drug carriers, barcodes, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance and safety depend not only on their particle size, size distribution, and morphology, but also on their surface chemistry, i.e., the total number of surface functional groups (FG) and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. It also underlines the importance of validated analytical methods that provide accurate information on these application-relevant physicochemical properties with a known uncertainty. In the case of FG quantification, this calls for robust, fast, inexpensive, and reliable methods which allow for the characterization of a broad variety of NM differing in size, chemical composition, and optical properties.
Methods
Aiming at the development of simple, versatile, and multimodal tools for the quantification of bioanalytically relevant FG such as amine, carboxy, thiol, and aldehyde functionalities, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance (NMR), mass spectrometry (MS), and thermal analysis methods.
Results
Here, we will present examples for different types of NMs and FGs including results from a currently running interlaboratory comparison (ILC) with the National Research Council of Canada (NRC) to pave the road for method standardization.
Innovative aspects
• Surface analysis
• Performance and safety of nanomaterials
• Standardization
Engineered nanomaterials (NM) with their large surface-to-volume ratios and their for some materials observed size-dependent functional properties are of increasing relevance for current and future developments in various fields such as medical and pharmaceutical industry, computing and electronics or food and consumer products. The performance and safety of NM are determined by the sum of their intrinsic physicochemical properties. Especially, the particle surface chemistry, which is largely controlled by the chemical nature and density of functional groups (FG) and ligands, is an important key driver for NM performance, stability, and processibility as well as the interaction of NM with the environment. Thus, methods for FG quantification can foster the sustainable development of functional and safe(r) NM.
Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made polymeric and silica particles of varying FG, used as optical pH sensors. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
Nowadays amorphous silica nanoparticles (SiO2-NP) are one of the most abundant engineered nanomaterials, that are highly stable and can be easily produced on a large scale at low cost. Surface functionalized SiO2-NP are of great interest in the life and material sciences, as they can be used e.g. as
drug carriers, fluorescent sensors, and multimodal labels in bioanalytical assays and imaging applications. Their performance in such applications depends not only on particle size, size distribution, and morphology, but also on surface chemistry, i.e. the total number of surface functional groups (FG)
and the number of FG accessible for subsequent functionalization with ligands or biomolecules, which in turn determines surface charge, colloidal stability, biocompatibility, and toxicity. Aiming at the development of simple, versatile, and multimodal tools for the quantification of many bioanalytically relevant FG and ligands, we investigated and compared various analytical methods commonly used for FG quantification. This includes electrochemical titration methods, dye-based optical assays, and other instrumental analytical techniques such as nuclear magnetic resonance and thermal analysis methods.
The potential of our multimodal approach for FG quantification was demonstrated for commercial and custom-made silica particles of varying FG, showing not only an influence of the synthesis methods on the number of FG but also on the performance. In the future, our strategy can contribute to establish multi-method characterization strategies to provide a more detailed picture of the structure-properties relationship.
Medium-resolution nuclear magnetic resonance spectroscopy (MR-NMR) currently develops to an important analytical tool for both quality control and processmonitoring. In contrast to high-resolution onlineNMR (HR-NMR),MR-NMRcan be operated under rough environmental conditions. A continuous re-circulating stream of reaction mixture fromthe reaction vessel to the NMR spectrometer enables a non-invasive, volume integrating online analysis of reactants and products. Here, we investigate the esterification of 2,2,2-trifluoroethanol with acetic acid to 2,2,2-trifluoroethyl acetate both by 1H HR-NMR (500MHz) and 1H and 19F MRNMR (43MHz) as amodel system. The parallel online measurement is realised by splitting the flow,which allows the adjustment of quantitative and independent flow rates, both in the HR-NMR probe as well as in the MR-NMR probe, in addition to a fast bypass line back to the reactor. One of the fundamental acceptance criteria for online MR-MNR spectroscopy is a robust data treatment and evaluation strategy with the potential for automation. The MR-NMR spectra are treated by an automated baseline and phase correction using the minimum entropy method. The evaluation strategies comprise (i) direct integration, (ii) automated line fitting, (iii) indirect hard modelling (IHM) and (iv) partial least squares regression (PLS-R). To assess the potential of these evaluation strategies for MR-NMR, prediction results are compared with the line fitting data derived from the quantitative HR-NMR spectroscopy. Although, superior results are obtained from both IHM and PLS-R for 1H MR-NMR, especially the latter demands for elaborate data pretreatment, whereas IHM models needed no previous alignment.
Die Entwicklung innovativer Medium-Resolution-NMR-Spektrometer eröffnet eine Reihe bemerkenswerter Applikationen für die Qualitätskontrolle, die akademische Ausbildung und die Prozessanalytik. Die Verwendung von Permanentmagneten erlaubt den Einsatz der NMR-Spektroskopie in industriellen Prozessumgebungen.
Quantitative determination of acidic surface sites is highly important for the characterization of solid acids because the activity of a catalyst is often related to the concentration of these sites. A recently developed method using 15N Nuclear Magnetic Resonance spectroscopy (NMR) for the quantification of acidic Lewis and Brønsted sites has been tested for a series of nanoscopic aluminum hydroxide fluorides. Comparison with other methods for the quantitative determination of acidic sites shows that this 15N NMR quantification method is a promising technique for the comprehensive investigation of acidic sites. Three different acidic sites, one Brønsted and two Lewis sites, can be distinguished by their 15N chemical shifts of pyridine and simultaneously quantified under conditions corresponding to catalytic reaction conditions. Determination of the individual concentrations of acidic sites allows further insight into the catalytic process. It was found that the concentration of Brønsted sites correlates with catalyzed conversion of citronellal to isopulegol in the investigated series of catalysts. Additionally, investigations indicate that one of the Lewis sites become blocked during the reaction of citronellal.
Medium resolution nuclear magnetic resonance (MR-NMR) spectroscopy is currently a fast developing field, which has an enormous potential to become an important analytical tool for reaction monitoring, in hyphenated techniques, and for systematic investigations of complex mixtures. The recent developments of innovative MR-NMR spectrometers are therefore remarkable due to their possible applications in quality control, education, and process monitoring. MR-NMR spectroscopy can beneficially be applied for fast, non-invasive, and volume integrating analyses under rough environmental conditions.
Within this study, a simple 1/16'' fluorinated ethylene propylene (FEP) tube with an ID of 0.04'' (1.02 mm) was used as a flow cell in combination with a 5 mm glass Dewar tube inserted into a benchtop MR-NMR spectrometer with a 1H Larmor frequency of 43.32 MHz and 40.68 MHz for 19F. For the first time, quasi-simultaneous proton and fluorine NMR spectra were recorded with a series of alternating 19F and 1H single scan spectra along the reaction time coordinate of a homogeneously catalysed esterification model reaction containing fluorinated compounds. The results were compared to quantitative NMR spectra from a hyphenated 500 MHz online NMR instrument for validation. Automation of handling, pre-processing, and analysis of NMR data becomes increasingly important for process monitoring applications of online NMR spectroscopy and for its technical and practical acceptance. Thus, NMR spectra were automatically baseline corrected and phased using the minimum entropy method. Data analysis schemes were designed such that they are based on simple direct integration or first principle line fitting, with the aim that the analysis directly revealed molar concentrations from the spectra.
Finally, the performance of 1/16'' FEP tube set-up with an ID of 1.02 mm was characterised regarding the limit of detection (LOQ (1H) = 0.335 mol L-1 and LOQ (19F) = 0.130 mol L-1 for trifluoroethanol in D2O (single scan)) and maximum quantitative flow rates up to 0.3 mL min-1. Thus, a series of single scan 19F and 1H NMR spectra acquired with this simple set-up already presents a valuable basis for quantitative reaction monitoring.
Time-optimized 15N quantitative NMR (qNMR) is described for the precise determination of Lewis and Brønsted site concentrations per gram catalyst, enabling a measurement time reduction of more than a factor of 10. The proof-of-principle is demonstrated for amorphous aluminum hydroxide fluorides with their tunable Lewis to Brønsted functionalities and relevance to highly active and selective heterogeneous catalysis using pyridine as a widely accepted probe molecule for Lewis and Brønsted sites. Two different Lewis centers were found, and reliable site concentrations down to the micromole per gram region can be determined. Furthermore, 1H{15N} REDOR NMR for the acid proton at the Brønsted site yields a distance of the 15N atom of bonded pyridine to this acid proton of (0.112 ± 0.002) nm, such that fast motion/diffusion of the Brønsted site-bonded pyridine at the surface can be excluded.
An isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) reference measurement procedure for Δ9-tetrahydrocannabinol (THC) in serum was developed and validated. The method complies with the concept of a ratio primary reference measurement procedure. The uncertainty was determined for two concentrations of THC in serum (1 ng/mL and 2.4 ng/mL). The calculation procedure is based on the Guide to the Expression of Uncertainty in Measurement (GUM). The relative expanded uncertainty was found to be less than 2% for both concentration levels, corresponding to a 95% confidence interval. For the reference method, it was shown that the measurement of THC within the concentration range covered by the current threshold values is very accurate. The method has the potential to provide traceability for the methods used in practical forensics.