Type-I pyrethroids are frequently used for disinfection purposes on airplanes from and to tropical areas as a preventive health measure to control or kill the insect vectors of human diseases including dengue, yellow fever and malaria. The aim of the presented work was the development of such a simple, rapid and effective method for pyrethroid analysis
The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min.
With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4]
The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min.
With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4]
Type-I pyrethroids are frequently used for disinfection purposes against insects such as adult mosquitoes, or diseases carried by insects, like Malaria or Zika in cabins of airplanes on long-distance flights especially from tropical destinations. This treatment is mandatory at various airports but compliance with the rules is difficult to test for. Moreover, if improperly used, these compounds can entail negative health effects for crews and passengers.
The detection of the pyrethroids will be achieved thanks to an antibody-gated indicator delivery system (gAID) utilizing monoclonal antibodies and hybrid sensory nanoparticles. After the interaction of the pyrethroid with the gAID, the liberated indicator (dye) will be detected. Since only few analyte molecules are necessary for pore opening yet release a large number of dyes, the system shows intrinsic signal amplification.
The device system to be developed has to be so simple that chemically untrained personnel, such as ground or cabin crew, can use it and obtain a result in a reasonably short period of time, e.g., ≤5 min. The need for high accuracy and sufficient sensitivity, established at 0.001 g m–2, is a critical requirement and imposes another significant challenge since this value is beyond current LFTs reported in the literature for pesticide detection to date.
In order to achieve the selectivity and sensitivity required by the test itself, and to avoid cross reactivity with other type I pyrethroids, the production of a monoclonal antibody for both Permethrin and Phenontrin is necessary. The synthesis of the two hapten molecules and the subsequent immunization with different immunogens represent the first goal of the work.
The goal of the project is the immunological detection of residual pesticides directly on site using rapidly responding lateral flow test (LFT) strips in combination with indicator dyes and smartphone-based readout and analysis. Specifically, the system consists on a class-selective LFT strip system, which will test for relevant pyrethroid pesticides (Permethrin, d-Phenothrin and others type-I pyrethroids) in parallel.
Type-I pyrethroids are frequently used for disinfection purposes against insects such as adult mosquitoes, or diseases carried by insects, like Malaria or Zika in cabins of airplanes on long-distance flights especially from tropical destinations. This treatment is mandatory at various airports but compliance with the rules is difficult to test for. Moreover, if improperly used, these compounds can entail negative health effects for crews and passengers.
The detection of the pyrethroids will be achieved thanks to an antibody-gated indicator delivery system (gAID) utilizing monoclonal antibodies and hybrid sensory nanoparticles. After the interaction of the pyrethroid with the gAID, the liberated indicator (dye) will be detected. Since only few analyte molecules are necessary for pore opening yet release a large number of dyes, the system shows intrinsic signal amplification.
The device system to be developed has to be so simple that chemically untrained personnel, such as ground or cabin crew, can use it and obtain a result in a reasonably short period of time, e.g., ≤5 min. The need for high accuracy and sufficient sensitivity, established at 0.001 g m–2, is a critical requirement and imposes another significant challenge since this value is beyond current LFTs reported in the literature for pesticide detection to date.
In order to achieve the selectivity and sensitivity required by the test itself, and to avoid cross reactivity with other type I pyrethroids, the production of a monoclonal antibody for both Permethrin and Phenontrin is necessary. The synthesis of the two hapten molecules and the subsequent immunization with different immunogens represent the first goal of the work.