The influence of the process gas, laser scan speed, and sample thickness on the build-up of residual stresses and porosity in Ti-6Al-4V produced by laser powder bed fusion was studied. Pure argon and helium, as well as a mixture of those (30% helium), were employed to establish process atmospheres with a low residual Oxygen content of 100 ppm O2. The results highlight that the subsurface residual stresses measured by X-ray diffraction were significantly lower in the thin samples (220 MPa) than in the cuboid samples (645 MPa). This difference was attributed to the shorter laser vector length, resulting in heat accumulation and thus in-situ stress relief. The addition of helium to the process gas did not introduce additional subsurface residual stresses in the simple geometries, even for the increased scanning speed. Finally, larger deflection was found in the cantilever built under helium (after removal from the baseplate), than in those produced under argon and an argon-helium mixture. This result demonstrates that complex designs involving large scanned areas could be subjected to higher residual stress when manufactured under helium due to the gas’s high thermal conductivity, heat capacity, and thermal diffusivity.
Distickstoffmonoxid (N2O, Lachgas) und Helium (He) sind gängige Prüfgase für Dichtheitsprüfungen. Die einfachste Leckgeometrie stellt ein ideal zylindrisches Rohr dar. Es wurden Glaskapillaren verschiedener Abmessungen mit Lachgas und Helium durchströmt. Der Überdruck am Kapillareingang lag zwischen 100 mbar und 400 mbar. Es handelte sich um vier annähernd zylindrische Glaskapillaren mit den mittleren Durchmessern: Kapillare 1: ca. 102 μm; Kapillare 2: ca. 71 μm; Kapillare 3B: ca. 49 μm; Kapillare 4: ca. 53 μm. Zudem wurde eine nichtzylindrische Kapillare geprüft (Kapillare 3A). Die Kapillaren 1, 2 und 3B wurden mit beiden Prüfgasen getestet. Kapillare 3A wurde nur mit Lachgas durchströmt, Kapillare 4 nur mit Helium.
Für die Messung der Leckageraten kam das Überdruckverfahren mit Ansammlung (Verfahren B3 nach DIN EN 1779: 1999-10) zum Einsatz. Als Detektor für Lachgas diente der Lachgasdetektor Maihak Unor 6 N, für Helium der Leckdetektor T-Guard der Firma Inficon.
Es wurden verschiedene Theorieansätze verglichen. Beim Theorieansatz Ib erfolgte die Umrechnung der Lachgas-Messwerte auf die Helium-Messwerte und umgekehrt anhand der Druck-, Temperatur- und Gasartabhängigkeit der Leckagerate für laminar-viskose Gasströmung (DIN EN 1779: 1999-10; DGZfP-Richtlinie DP2: 2009-12). Beim Theorieansatz II wurde die Berechnung der Leckagerate für die laminar-viskose Rohrströmung unter der Annahme einer ideal zylindrischen Kapillare durchgeführt. Zusätzlich wurde mit „ANSYS Fluent“ eine CFD-Simulation vorgenommen. Bei Kapillare 3A wurde eine Serienschaltung der Strömungsleitwerte von Rohr und Düse angesetzt. Bei Anwendung des Ansatzes Ib werden bei Umrechnung der Helium-Messwerte auf Lachgas die Lachgas-Messwerte überschätzt. Umgekehrt werden bei der Umrechnung der Lachgas-Messwerte auf Helium die Helium-Messwerte unterschätzt. Bei Analyse der Einlauflängen der Rohrdurchströmung ist festzustellen, dass diese für Lachgas stets größer als für Helium sind. Bei Lachgas liegt daher für einige Messwerte noch keine ausgebildete laminare Rohrströmung vor. Einlaufeffekte können somit nicht vernachlässigt werden. Als Fazit ergibt sich, dass bei Verwendung von Helium als Prüfgas und Umrechnung der Helium-Messwerte auf Lachgas die Lachgas-Leckageraten sicherheitstechnisch konservativ abgeschätzt werden.
Distickstoffmonoxid (N2O, Lachgas) und Helium (He) sind gängige Prüfgase für Dichtheitsprüfungen. Die einfachste Leckgeometrie stellt ein ideal zylindrisches Rohr dar. Es wurden Glaskapillaren verschiedener Abmessungen mit Lachgas und Helium durchströmt. Der Überdruck am Kapillareingang lag zwischen 100 mbar und 400 mbar. Es handelte sich um vier annähernd zylindrische Glaskapillaren mit den mittleren Durchmessern: Kapillare 1: ca. 102 μm; Kapillare 2: ca. 71 μm; Kapillare 3B: ca. 49 μm; Kapillare 4: ca. 53 μm. Zudem wurde eine nichtzylindrische Kapillare geprüft (Kapillare 3A). Die Kapillaren 1, 2 und 3B wurden mit beiden Prüfgasen getestet. Kapillare 3A wurde nur mit Lachgas durchströmt, Kapillare 4 nur mit Helium. Für die Messung der Leckageraten kam das Überdruckverfahren mit Ansammlung (Verfahren B3 nach DIN EN 1779: 1999-10) zum Einsatz. Als Detektor für Lachgas diente der Lachgasdetektor Maihak Unor 6 N, für Helium der Leckdetektor T-Guard der Firma Inficon.
Es wurden verschiedene Theorieansätze verglichen. Beim Theorieansatz Ib erfolgte die Umrechnung der Lachgas-Messwerte auf die Helium-Messwerte und umgekehrt anhand der Druck-, Temperatur- und Gasartabhängigkeit der Leckagerate für laminar-viskose Gasströmung (DIN EN 1779: 1999-10; DGZfP-Richtlinie DP2: 2009-12). Beim Theorieansatz II wurde die Berechnung der Leckagerate für die laminar-viskose Rohrströmung unter der Annahme einer ideal zylindrischen Kapillare durchgeführt. Zusätzlich wurde mit „ANSYS Fluent“ eine CFD-Simulation vorgenommen. Bei Kapillare 3A wurde eine Serienschaltung der Strömungsleitwerte von Rohr und Düse angesetzt. Bei Anwendung des Ansatzes Ib werden bei Umrechnung der Helium-Messwerte auf Lachgas die Lachgas-Messwerte überschätzt. Umgekehrt werden bei der Umrechnung der Lachgas-Messwerte auf Helium die Helium-Messwerte unterschätzt. Bei Analyse der Einlauflängen der Rohrdurchströmung ist festzustellen, dass diese für Lachgas stets größer als für Helium sind. Bei Lachgas liegt daher für einige Messwerte noch keine ausgebildete laminare Rohrströmung vor. Einlaufeffekte können somit nicht vernachlässigt werden. Als Fazit ergibt sich, dass bei Verwendung von Helium als Prüfgas und Umrechnung der Helium-Messwerte auf Lachgas die Lachgas-Leckageraten sicherheitstechnisch konservativ abgeschätzt werden.
Distickstoffmonoxid (N2O, Lachgas) und Helium (He) sind gängige Prüfgase für Dichtheitsprüfungen. Die einfachste Leckgeometrie stellt ein ideal zylindrisches Rohr dar. Es wurden Glaskapillaren verschiedener Abmessungen mit Lachgas und Helium durchströmt. Der Überdruck am Kapillareingang lag zwischen 100 mbar und 400 mbar. Es handelte sich um vier annähernd zylindrische Glaskapillaren mit den mittleren Durchmessern: Kapillare 1: ca. 102 µm; Kapillare 2: ca. 71 µm; Kapillare 3B: ca. 49 µm; Kapillare 4: ca. 53 µm. Zudem wurde eine nichtzylindrische Kapillare geprüft (Kapillare 3A). Die Kapillaren 1, 2 und 3B wurden mit beiden Prüfgasen getestet. Kapillare 3A wurde nur mit Lachgas durchströmt, Kapillare 4 nur mit Helium.
Für die Messung der Leckageraten kam das Überdruckverfahren mit Ansammlung (Verfahren B3 nach DIN EN 1779: 1999-10) zum Einsatz. Als Detektor für Lachgas diente der Lachgasdetektor Maihak Unor 6 N, für Helium der Leckdetektor T-Guard der Firma Inficon.
Es wurden verschiedene Theorieansätze verglichen. Beim Theorieansatz Ib erfolgte die Umrechnung der Lachgas-Messwerte auf die Helium-Messwerte und umgekehrt anhand der Druck-, Temperatur- und Gasartabhängigkeit der Leckagerate für laminar-viskose Gasströmung (DIN EN 1779: 1999-10; DGZfP-Richtlinie DP2: 2009-12). Beim Theorieansatz II wurde die Berechnung der Leckagerate für die laminar-viskose Rohrströmung unter der Annahme einer ideal zylindrischen Kapillare durchgeführt. Zusätzlich wurde mit „ANSYS Fluent“ eine CFD-Simulation vorgenommen. Bei Kapillare 3A wurde eine Serienschaltung der Strömungsleitwerte von Rohr und Düse angesetzt.
Bei Anwendung des Ansatzes Ib werden bei Umrechnung der Helium-Messwerte auf Lachgas die Lachgas-Messwerte überschätzt. Umgekehrt werden bei der Umrechnung der Lachgas-Messwerte auf Helium die Helium-Messwerte unterschätzt. Bei Analyse der Einlauflängen der Rohrdurchströmung ist festzustellen, dass diese für Lachgas stets größer als für Helium sind. Bei Lachgas liegt daher für einige Messwerte noch keine ausgebildete laminare Rohrströmung vor. Einlaufeffekte können somit nicht vernachlässigt werden. Als Fazit ergibt sich, dass bei Verwendung von Helium als Prüfgas und Umrechnung der Helium-Messwerte auf Lachgas die Lachgas-Leckageraten sicherheitstechnisch konservativ abgeschätzt werden.
The International Dangerous Goods Regulations prescribe the immersion under water method (“bubble test”) as standard method for the leakproofness test of dangerous goods packagings. But this test procedure acts as a test method for leak localisation, not for quantitative leakage rates measurement. Additionally, the sensitivity in detecting leaks of small diameters is restricted, depending on the test liquid and the test pressure. The bubble test is not suitable for a comparison with quantitative limit leakage rates based on realistic transport conditions. This is especially important when estimating the risk of the formation of an explosive atmosphere during the intercontinental carriage of dangerous goods packagings in freight containers. To compare measured leakage rates with limit leakage rates, a quantitative leak testing procedure is required. Therefore a new approach for dangerous goods packagings is implemented: The pressure technique by accumulation using Helium as a tracer gas. This work presents the test equipment necessary for the quantitative measurement of Helium leakage rates through closures of different kinds of dangerous goods packagings. The essential steps to achieve good repeatable results are: A controlled Helium filling process to reach a defined test pressure in the test sample, a sufficient homogenisation of the Helium-air-mixture inside the test sample and the ensuring of a constant pressure level of the test sample during the test. The Helium loss rate of the accumulation chamber has to be measured separately to receive a correction factor for the measured leakage rates. Different constructional measures are introduced to prevent a disturbing influence of the Helium leakage rate of the filling valves on the measurement results. Methods to estimate the disturbing effect of Helium permeation through permeable parts of the test sample are also presented. As a supporting method for the experimental investigations the Helium sniffer test can be applied. This practical application-oriented advice can enable other users to establish a pressure technique by accumulation for their own technical field.
Abstract. The International Dangerous Goods Regulations prescribe the immersion under water method (“bubble test”) as standard method for the leakproofness test of dangerous goods packagings. But this test procedure acts as a test method for leak localisation, not for quantitative leakage rates measurement. Additionally, the sensitivity in detecting leaks of small diameters is restricted, depending on the test liquid and the test pressure. The bubble test is not suitable for a comparison with quantitative limit leakage rates based on realistic transport conditions. This is especially important when estimating the risk of the formation of an explosive atmosphere during the intercontinental carriage of dangerous goods packagings in freight containers.
To compare measured leakage rates with limit leakage rates, a quantitative leak testing procedure is required. Therefore a new approach for dangerous goods packagings is implemented: The pressure technique by accumulation using Helium as a tracer gas.
This work presents the test equipment necessary for the quantitative measurement of Helium leakage rates through closures of different kinds of dangerous goods packagings. The essential steps to achieve good repeatable results are: A controlled Helium filling process to reach a defined test pressure in the test sample, a sufficient homogenisation of the Helium-air-mixture inside the test sample and the ensuring of a constant pressure level of the test sample during the test. The Helium loss rate of the accumulation chamber has to be measured separately to receive a correction factor for the measured leakage rates. Different constructional measures are introduced to prevent a disturbing influence of the Helium leakage rate of the filling valves on the measurement results. Methods to estimate the disturbing effect of Helium permeation through permeable parts of the test sample are also presented. As a supporting method for the experimental investigations the Helium sniffer test can be applied.
This practical application-oriented advice can enable other users to establish a pressure technique by accumulation for their own technical field.
The International Dangerous Goods Regulations prescribe the immersion under water method (“bubble test”) as standard method for the leakproofness test of dangerous goods packagings. But this test procedure acts as a test method for leak localisation, not for quantitative leakage rates measurement. Additionally, the sensitivity in detecting leaks of small diameters is restricted, depending on the test liquid and the test pressure. The bubble test is not suitable for a comparison with quantitative limit leakage rates based on realistic transport conditions. This is especially important when estimating the risk of the formation of an explosive atmosphere during the intercontinental carriage of dangerous goods packagings in freight containers.
To compare measured leakage rates with limit leakage rates, a quantitative leak testing procedure is required. Therefore a new approach for dangerous goods packagings is implemented: The pressure technique by accumulation using Helium as a tracer gas.
This work presents the test equipment necessary for the quantitative measurement of Helium leakage rates through closures of different kinds of dangerous goods packagings. The essential steps to achieve good repeatable results are: A controlled Helium filling process to reach a defined test pressure in the test sample, a sufficient homogenisation of the Helium-air-mixture inside the test sample and the ensuring of a constant pressure level of the test sample during the test. The Helium loss rate of the accumulation chamber has to be measured separately to receive a correction factor for the measured leakage rates. Different constructional measures are introduced to prevent a disturbing influence of the Helium leakage rate of the filling valves on the measurement results. Methods to estimate the disturbing effect of Helium permeation through permeable parts of the test sample are also presented. As a supporting method for the experimental investigations the Helium sniffer test can be applied. This practical application-oriented advice can enable other users to establish a pressure technique by accumulation for their own technical field.
The basis for the development and evaluation of equations of state for mixtures is experimental data for several thermodynamic properties. The quality and the availability of experimental data limit the achievable accuracy of the equation. Referring to the fundamentals of GERG-2008 wide-range equation of state, no suitable data were available for many mixtures containing secondary natural gas components. This work provides accurate experimental (p,rho,T) data for two binary mixtures of methane with Helium (0.95 (amount-of-substance fraction) CH4 + 0.05 He and 0.90 CH4 + 0.10 He). Density measurements were performed at temperatures between (250 and 400) K and pressures up to 20 MPa by using a single-sinker densimeter with magnetic suspension coupling. Experimental data were compared with the corresponding densities calculated from the GERG-2008 and the AGA8-DC92 equations of state. Deviations from GERG-2008 were found within a 2% band for the (0.95 CH4 + 0.05 He) mixture but exceeded the 3% Limit for the (0.95 CH4 + 0.05 He) mixture. The highest deviations were observed at T = 250 K and pressures between (17 and 19) MPa. Values calculated from AGA8-DC92, however, deviated from the experimental data by only 0.1% at high pressures and exceeded the 0.2% limit only at temperatures of 300 K and above, for the (0.90 CH4 + 0.10 He) mixture.