The Federal Institute for Materials Research and Testing (BAM) has developed a load-based test method (compensation method) to determine the energy efficency of heat pumps and air conditioners. The method allows for testing with unfixed compressor speed and active control of the unit. Thus, at low part loads the unit under test is allowed to cycle on-off, when the frequency of the compressor drops below its minimum threshold. Therefore, the associated efficiency losses are directly measured and correction calculations as for the current steady state tests become obsolete. In addition, the testing can be performed without the support of the manufacturer by market surveillance authorities, for instance, since no frequency and expansion valve settings are required. To prove that the compensation method is repeatable and reproducible three round robin tests have been organised by BAM.
Test methods for heat pumps
(2020)
To determine the seasonal performance of heat pumps for energy labelling this study proposes a two-point-method that could conceivably be an alternative to the European standard EN 14825 and similar test standards such as ISO 13256. Heat pumps were tested in line with the EN 14825. The reduction of measurement points, from between five to seven (EN 14825) to only two (two-point-method), leads to 60 % savings in cost and time. It is shown that the shortened method can be used to determine the seasonal energy efficiency of heat pumps with the same degree of precision compared to EN 14825.
To determine the seasonal performance of heat pumps for energy labelling this study proposes a two-point-method that could conceivably be an alternative to the European standard EN 14825 and similar test standards such as ISO 13256. Heat pumps were tested in line with the EN 14825. The reduction of measurement points, from between five to seven (EN 14825) to only two (two-point-method), leads to 60 % savings in cost and time. It is shown that the shortened method can be used to determine the seasonal energy efficiency of heat pumps with the same degree of precision compared to EN 14825.
The growing market penetration of heat pumps indicates the need for a performance test method that better reflects the dynamic behavior of heat pumps. In this contribution, we developed and implemented a dynamic test method for the evaluation of the seasonal performance of heat pumps by means of laboratory testing. Current standards force the heat pump control inactive by fixing the compressor speed. In contrast, during dynamic testing, the compressor runs unfixed while the heat pump is subjected to a temperature profile. The profile consists of the different outdoor temperatures of a typical heating season based on the average European climate and also includes temperature changes to reflect the dynamic behavior of the heat pump. The seasonal performance can be directly obtained from the measured heating energy and electricity consumption making subsequent data interpolation and recalculation with correction factors obsolete. The method delivers results with high precision and high reproducibility and could be an appropriate method for a fair rating of heat pumps.
The European Standards EN14511 and EN14825 are representing standardized procedures for testing the energy efficiency of heat pumps and air conditioners with electrically driven compressors for both space heating and cooling. In this study, these standards are analyzed and validated. It was figured out that the currently used methods implicate high complexity and high financial effort. In order to clarify the circumstances and to identify the deficits more in detail, a round robin test with independent and accredited laboratories was initiated. The aim is to develop an optimized test procedure that improves the feasibility of the testing procedure and finally its application. This study should lead to a repeatable and reproducible testing procedure, which is also compatible with the state of the art in heat pump technology and real operation conditions.