In the event of moisture deterioration, rapid detection and localization is particularly important to prevent further deterioration and costs. For building floors, the layered structure poses a challenging obstacle for most moisture measurement methods. But especially here, layer-specific information on the depth of the water is crucial for efficient and effective repairs. Ground Penetrating Radar (GPR) shows the potential to generate such depth information. Therefore, the present work investigates the suitability of GPR in combination with machine learning methods for the automated classification of the typical deterioration cases (i) dry, (ii) wet insulation, and (iii) wet screed.
First, a literature review was conducted to identify the most common methods for detecting moisture in building materials using GPR. Here, it especially became clear that all publications only investigated individual time-, amplitude- or frequency features separately, without combining them. This was seen as a potential aspect for innovation, as the multivariate application of several signal features can help to overcome individual weaknesses and limitations.
Preliminary investigations carried out on drying screed samples confirmed the profitable use of multivariate evaluations. In addition to the general suitability and dependencies of various features, first limitations due to possible interference between the direct wave and the reflection wave could be identified. This is particularly evident with thin or dry materials, for which the two-way travel times of the reflected radar signals become shorter.
An extensive laboratory experiment was carried out, for which a modular test specimen was designed to enable the variation of the material type and thickness of screed and insulation, as well as the simulation of moisture deteriorations. The data collected revealed clear differences between dry and deteriored structures within measured B-scans. These deviations were to be detected with the newly introduced B-scan features, which evaluate the statistical deviation of A-scan features within a survey line. In this way, deteriorations to unknown floor structures are recognized, regardless of the material parameters present. In a subsequent training and cross-validation process of different classifiers, accuracies of over 88 \% of the 504 recorded measurements (252 different experimental setups) were achieved. For that, the combination of amplitude and frequency features, which covered all relevant reflections of the radar signals, was particularly beneficial. Furthermore, the data set showed only small differences between dry floors and deteriored screeds for the B-scan features, which could be attributed to a homogeneous distribution of the added water in the screeds. The successfully separation of these similar feature distributions raised the suspicion of overfitting, which was examined in more detail by means of a validation with on-site data.
For this purpose, investigations were carried out at five different locations in Germany, using the identical measurement method like in the laboratory. By extracting drilling cores, it was possible to determine the deterioration case for each measurement point and thus generate a corresponding reference. However, numerous data had to be sorted out before classification, since disturbances due to underfloor heating, screed reinforcements, steel beams or missing insulation prevented comparability with the laboratory experiments. Validation of the remaining data (72 B-scans) achieved only low accuracy with 53 \% correctly classified deterioration cases. Here, the previously suspected overfitting of the small decision boundary between dry setups and deteriored screeds within the laboratory proved to be a problem. The generally larger deviations within (also dry) on-site B-scans were thus frequently misclassified as screed deterioration. In addition, there were sometimes strongly varying layer thicknesses or changing cases of deterioration within a survey line, which caused additional errors due to the local limitation of the drilling core reference. Nevertheless, individual on-site examples also showed the promising potential of the applied signal features and the GPR method in general, which partly allowed a profound interpretation of the measurements. However, this interpretation still requires the experience of trained personnel and could not be automated using machine learning with the available database. Nevertheless, such experience and knowledge can be enriched by the findings of this work, which provide the basis for further research.
Future work should aim at building an open GPR data base of on-site moisture measurements on floors to provide a meaningful basis for applying machine learning. Here, referencing is a crucial point, whose limitations with respect to the moisture present and its distribution can easily reduce the potential of such efforts. The combination of several reference methods might help to overcome such limitations. Similarly, a focus on monitoring approaches can also help to reduce numerous unknown variables in moisture measurements and increase confidence in the detection of different deterioration cases.
This paper studies the dispersion of GPR wave’s phase velocity at different wideband frequencies in plywood and concrete with varying moisture content. This study makes use of two GPR antennas with 2 GHz centre frequency operating in wide angle reflection and refraction (WARR) mode and with computation of spectral analysis of the surface wave (SASW). Computation of phase velocities is based on the Acquisition of the cross-power spectrum and phase unwrap of two distorted ground waves at positions Closer to and farther away from the transmitting antenna. The velocities of the ground waves are found to experience greater dispersion in low frequency regimes within the effective frequency bandwidths determined and thresholded by time–frequency analysis (TFA) and coherence plotting of the ground waves.
This study validates not only the methodology, but also identifies the optimal distance between the first (Rx1) and second (Rx2) receivers as k/2, which is based on a fixed transmitter (Tx) minus the first Receiver (Rx1) distance. It serves as an indication of changeable separation distance when other lower frequency GPR is used because the distances of Tx-Rx1 and Rx1-Rx2 are wavelength dependent and thus also frequency dependent. Effects of moisture contents and chloride contamination in concrete were also characterized according to the dispersion plots . that wave traelling in lower frequencies in GPR wave is much decelerated than that in higher frequencies. This research also contributes to the building of the ‘‘GPRWARR machine” suggested in Annan and Jackson (2017) [1], within which the effects of wave Dispersion on phase velocity can be inversely modelled to characterize variations in the material properties of infrastructure as a means of detecting surface damage.
We investigated the possibility of surrounding waves
along with perimeter of large diameter tendon ducts during
ground penetrating radar (GPR) testing of concrete structures.
The surrounding waves influence the primary reflection from
tendon duct and alter the phase as well as amplitude of signal
depending on the diameter of the tendon duct. This phenomenon
was studied in detail by conducting several simulations using a
commercial software Reflexw®. Finite Difference Time Domain
method was adopted to analyze reflection patterns from objects
of various diameters located at different depths in concrete
media.
The proposed methodology will be useful in qualitative
assessment of size of metallic objects greater than a diameter of
6 cm. In general, the identification of large diameter tendon ducts
in a civil structure is carried out by prior knowledge of the civil
plan and its diagonal appearance to smaller diameter object
mesh. The proposed methodology will enhance the confidence in
identification of the larger diameter tendon ducts even if the civil
plan is not known accurately.
We investigated the possibility of surrounding waves along with perimeter of large diameter tendon ducts during ground penetrating radar (GPR) testing of concrete structures. The surrounding waves influence the primary reflection from tendon duct and alter the phase as well as amplitude of signal depending on the diameter of the tendon duct. This phenomenon was studied in detail by conducting several simulations using a commercial software Reflexw®. Finite Difference Time Domain method was adopted to analyze reflection patterns from objects of various diameters located at different depths in concrete media.
The proposed methodology will be useful in qualitative assessment of size of metallic objects greater than a diameter of 6 cm. In general, the identification of large diameter tendon ducts in a civil structure is carried out by prior knowledge of the civil plan and its diagonal appearance to smaller diameter object mesh. The proposed methodology will enhance the confidence in identification of the larger diameter tendon ducts even if the civil plan is not known accurately.
Post-tensioning systems provide safe and efficient construction solutions for long span bridges. Despite the improved grouting practices over the past decade, existing post-tensioning systems may have significant amount of grout defects, which could lead to corrosion of the strands. Condition assessment of post-tensioning systems is necessary to allow bridge owners to take timely, proactive actions to mitigate or prevent further Deterioration and unanticipated tendon failures. A detailed experimental study conducted to assess the performance of nondestructive evaluation techniques in detecting grout defects within internal tendons is presented herein.
Nondestructive evaluation techniques that include Ground Penetrating Radar, Impact Echo, Ultrasonic Tomography, and Ultrasonic Echo are evaluated in terms of detecting the location and severity of fabricated grout defects in a full-scale post-tensioned U-girder mock-up specimen. While Ground Penetrating Radar can identify the location and profile of the internal tendons, particularly metal ducts due to strong reflections, this method did not provide any information about the defect conditions within the tendon. Both Impact Echo and Ultrasonic Echo techniques are effective in identifying the Location of grout defects, but could not differentiate between water, void, or compromised grout conditions. The study clearly demonstrates the need for NDE techniques that are applicable to anchorage regions, and that are capable of estimating the severity and nature of grout defects in internal tendons.
Research and Development in Non-Destructive Testing in Civil Engineering at BAM has de-veloped over more than two decades. Highlights of present research are ultrasound phase array probes, ground penetrating radar applications for the assessment of existing structures and Laser Induced Breakdown Spec-troscopy (LIBS) to determine which chemical elements on the surface of a specimen are. RFID sensor devel-opments for wireless moisture monitoring and data fusion for the combined analysis of sensor data are fast developing areas. In addition, a selection of application cases is briefly described.
The concreting of prefabricated concrete structures can lead to insufficient bonding or even to remaining cavities. Honeycombs (aggregate clusters without cement) represent potential weakening of the structure and need to be detected non-destructively. In our study we tested the capability of ground penetrating radar (GPR) techniques for this purpose. We applied GPR in reflection mode and zero-offset profiling (ZOP) transmission mode on a precast concrete twin wall with built-in honeycombs. GPR measurements were performed as two channel measurement with ground coupled antennas with centre frequencies of 1.5 GHz and 2.6 GHz mounted to an automated scanner system.
Our findings show that ZOP transmission measurements are a more efficient method to detect voids in reinforced concrete structures compared to reflection mode measurements. This holds for both the effort needed for the measurement and the evaluation as well as the validity of the data. Honeycombs (basically representing voids) are usually characterized by strongly reduced amplitudes and earlier arrivals of the transmitted wave.
The concreting of prefabricated concrete structures can lead to insufficient bonding or even to remaining cavities. Honeycombs (aggregate clusters without cement) represent potential weakening of the structure and need to be detected non-destructively. In our study we tested the capability of ground penetrating radar (GPR)techniques for this purpose. We applied GPR in reflection mode and zero-offset profiling (ZOP) Transmission mode on a precast concrete twin wall with built-in honeycombs. GPR measurements were performed as twochannel measurement with ground coupled antennas with centre frequencies of 1.5 GHz and 2.6 GHz mounted to an automated scanner system.
Our findings show that ZOP transmission measurements are a more efficient method to detect voids in reinforced concrete structures compared to reflection mode measurements. This holds for both the effort needed for the measurement and the evaluation as well as the validity of the data. Honeycombs (basically representing voids) are usually characterized by strongly reduced amplitudes and earlier arrivals of the transmitted wave.
Amplitudes variation of GPR rebar reflection due to the influence of concrete aggregate scattering
(2015)
Dense GPR measurements of rebar reflection amplitudes Show relative variations, which can be in the order of more than 10% - 20%. Former investigations demonstrated that these variations are caused by the heterogeneity of concrete, i.e. due to the inclusion of aggregates in concrete. These amplitude variations make it difficult to analyse single reflection amplitudes in order to determine the rebar diameter or to estimate the concrete deterioration state. In a systematic study we have quantified the statistical variation of the rebar reflection amplitude for concrete covers of 6 cm, 9 cm, 12 cm, 15 cm and 18 cm, for two different grading curves and for the rebar diameters 12 mm and 28 mm. Also the influence of the wavelength has been investigated by using antennas with different centre frequencies in relation to the aggregate size. The results are discussed with regard to a quantitative amplitude evaluation of GPR measurements and also the potential of using these variations for a characterization of concrete material properties.
Estimation of ground penetrating radar's wave velocity in materials is a critical step to accurately estimate depth of embedded line objects in concrete structures, and wetness of material. Errors of velocity are defined as the deviations between the velocities obtained in various oblique angles and those obtained in the traverse normal to the object orientation in a common offset antenna setting. In this paper, we quantified and corrected the errors of such estimation. GPR traverses were designed to travel in various oblique angles θ (90°, 75°, 60° and 45°) relative to the steel bars at 5 cover depths (55 mm, 85 mm, 115 mm, 145 mm and 175 mm). GPR wave velocity at any position within the lateral detection range of steel bars was measured with simple trigonometry in a semi-automated in-house program. It was found that reduction of oblique angles (i.e. θ<90°) causes flatter hyperbolic reflections and the associated errors of velocity can be as much as 30% in the case of an oblique angle 45° before correction. Such errors were corrected after re-scaling the horizontal travel distance with a multiplication factor of sin θ.