Related work
Laboratory Study:
Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors
https://doi.org/10.3390/app11198820
On-Site Study:
TBA
Doctoral Thesis:
Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar
https://doi.org/10.14279/depositonce-19306
Measurement Parameters
The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied.
Folder Description:
Lab_dry, Lab_insulDamage, Lab_screedDamage
- each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage.
- each floor setup was measured twice on two orthogonal survey lines, indicated by _Line1_ and _Line2_ in the file name.
- the file names encode the building floor setup e.g. CT50XP100 describes a 50 mm cement screed with 100 mm extruded polystyrene below
- the material codes are
CT: cement screed, CA: anhydrite screed, EP: expanded polystyrene, XP: extruded polystyrene, GW: glass wool, PS: perlites
further information can be found in the publication https://doi.org/10.3390/app11198820
OnSite_
- 5 folders containing B-Scans on 5 different practical moisture damages
- the building floor setup is encoded according to the lab with an additional measurement point numbering at the start and a damage case annotation at the end of the file name with _dry, _insulationDamage and_screedDamage
File Description:
B-Scans, Measurement files - no header
- dimension: 512 x N data point with N beeing the number of A-Scans including 512 samples of a 11 ns time window.
- survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan
Moisture References
- Moist_Reference of On-Site Locations include the columns MeasPoint: Measurement point, wt%Screed: moisture content of screed layer in mass percent; wt%Insul: moisture content of insulation layer in mass percent. References were obtained by drilling cores with 68 mm diameter in the center of each survey line.
- Moist_Reference_Screed of Lab data include the columns Screed: Screed material and thickness in mm, wt%Screed moisture content of screed layer in mass percent
- Moist Reference_Insul of Lab data include the columns Insulation: Insulation material and thickness in mm, water addition in l: water added to the insulation layer in liters, V%Insulation: water added to the insulation layer in volume percent, RH%: resulting relative humidy in the insulation layer during measurement. These References are only avaible for Lab measurements on insulation damages.
In this article, we present a laboratory experiment to monitor the accelerated corrosion in concrete using ground-penetrating radar (GPR). Four concrete test specimens were cast with rebars of different size and placed at different depths. The lifetime decades of reinforcement corrosion process were accelerated into 18 days by using the impress current technique. The electrochemical corrosion process was periodically monitored with GPR. Two control specimens were also prepared to investigate the influence of chloride contamination on GPR signal. The measured data were analysed both in time and frequency domains. In time domain, the peak-to-peak amplitude of a wave reflected by a rebar was calculated to investigate the relationship between an increase in signal amplitude and the degree of corrosion. In frequency domain, the time–frequency representations of the signal were computed by using S-transform. The results show that reinforce corrosion increased the amplitude of reflected signal in time domain but did not change the peak frequency in frequency domain while chloride contamination attenuates the signal to smaller amplitude and lower peak frequency. Based on the results, a novel process is finally proposed for GPR-based corrosion detection.
Tunnel lining evaluation is performed in the Hanging Lake Tunnel near Glenwood Springs, Colorado, using variations of four nondestructive evaluation (NDE) methods: air- and ground-coupled ground penetrating radar (GPR), ultrasonic echo (US echo), ultrasonic tomography (UST), and impact echo (IE). Potential regions of interest are identified using high-speed air-coupled GPR and visual inspection. A robotic frame with pneumatically-operated vacuum plates was used to automate the ground-coupled GPR, US echo, and IE tests, while the UST technique was used manually. This study shows that a particular combination of NDE techniques is a powerful tool for assessing the condition of tunnel linings and can detect potential anomalies such as delamination, depth of surface cracks, reinforcement depth and layout, and lining thickness. By mapping the phase shift of the ultrasonic pulses at detected interface, the potential bonding of layer interfaces and reinforcement is assessed.
An in-depth investigation of tunnel linings is performed at Eisenhower Tunnel, 60 miles west of Denver, Colorado, using a combination of four nondestructive testing methods: air- and ground-coupled ground penetrating radar (GPR), ultrasonic echo (US echo), ultrasonic tomography (UST), and impact echo (IE). A robotic frame with pneumatically operated vacuum plates is used to automate GPR, US echo, and IE. UST was performed manually. These techniques are used to identify and locate the reinforcement mesh and structural steel ribs. Local changes in ultrasonic phase are calculated by phase analysis processing techniques and apparent relationships between positive and negative phase shifts and steel and air interfaces are observed. According to previous laboratory research, these relationships indicate the bonded state between the concrete and the embedded steel, but without ground truth verification this can only be suggested. It is shown that this combination of methods can be used synergistically to provide tunnel owners with the layout and possible condition of tunnel lining reinforcement and structural components.
Monitoring accelerated corrosion in chloride contaminated concrete with ground penetrating radar
(2012)
Ground penetrating radar (GPR) was used to characterize the frequency-dependent dielectric relaxation phenomena in ordinary Portland cement (OPC) hydration in concrete changing from fresh to hardened state. The study was experimented by measuring the changes of GPR A-scan waveforms over a period of 90 days, and processed the waveforms with short-time Fourier transform (STFT) in joint time-frequency analysis (JTFA) domain rather than a conventional time or frequency domain alone. The signals of the direct wave traveled at the concrete surface and the reflected wave from an embedded steel bar were transformed with STFT, in which the changes of peak frequency over ages were tracked. The peak frequencies were found to increase with ages and the patterns were found to match closely with primarily the well-known OPC hydration process and secondarily, the evaporation effect. The close match is contributed to the simultaneous effects converting free to bound water over time, on both conventional OPC hydration and dielectric relaxation mechanisms.