Filtern
Dokumenttyp
Sprache
- Englisch (5)
Schlagworte
- Flash lamp (5) (entfernen)
Organisationseinheit der BAM
The knowledge about energy release and transient behaviour of flash lamps, used as short-term energy source in flash thermography investigations, is essential for a quantitative analysis of the results as well as for simulations regarding such experiments. Usually, only a rectangular pulse shape of a typical duration of a few milliseconds is regarded when flash lamps pulses are described. This note considers the afterglow period of a flash lamp explicitly and shows that negligence of this afterglow effect leads to a systematic underestimation of the pulse length and the related total energy release. In the reported case, the intensity transient recorded by a Silicon photo diode was transformed into a temperature transient, allowing the study of the real energy release. It turns out that approximately only 50% of the entire pulse energy were released during the usually regarded period of 2.8 ms, while the other half was released within a period of 20 ms with an exponential decay.
Comparison of concepts for a point-shaped energy density detector after flash lamp excitation
(2016)
The paper describes investigations and Research work in order to develop a simple sensor for the quantification of spectral broadband energy Dissipation of flash lamps at any point in space. Such Flash lamps are often used as energy source during active thermography testing (TT). Here, the temperature transient of the sensor surface has to be recorded by the infrared camera that is already present. During the following data evaluation, the energy input into the investigated specimen can be determined. Two opposite concepts were considered: thermal thick and thermal thin probes. The direct comparison shows advantages for thermal thick probes based on the physics of thermal balance processes.
Flash lamps are widely used excitation sources in the field of non-destructive testing with active thermography. Though the realized energy density in front of the investigated object is a significant factor with regard to detection sensitivity, only few data concerning this issue have been published so far. It is shown here that local energy densities can be estimated by means of a simple metal plate, which exhibits a certain temperature increase after flash excitation. After discussing the underlying calorimetric principle the sensor concept is reviewed using constant blackbody radiation and short laser pulses, since both kinds of sources generate known energy densities. The relative uncertainty of measurements of the energy density is found to be in the range of 10%. The last part of the present paper describes an application for characterizing the radiation of a usual 6 kJ flash lamp. The energy conversion efficiency was found to be only about 11%.