Several attempts have been made in the past to develop a European harmonized testing and assessment method for façades before the European commission decided to publish a call for tender on the topic. A project consortium from five countries (Sweden, UK, France, Germany and Hungary) applied to the call for tender and was contracted to develop a European approach to assess the fire performance of façades. 24 sub-contractors and 14 stakeholder entities were part of the project. The objective of the European project was to address a request from the Standing Committee of Construction (SCC) to provide EC Member States regulators with a means to regulate the fire performance of façade systems based on a European Approach agreed by SCC. The initial stages of this Project were focused on establishing a Register of the regulatory requirements in all Member States in relation to the fire Performance of façade systems, and to identify those Member States who have regulatory requirements for the fire performance façade systems which go beyond the current EN 13501 (reaction to fire and fire resistance) classification systems and to collate the details of these additional requirements. After having confirmed the regulatory needs a testing and classification methodology based on BS 8414 and DIN 4102-20 was developed to address the identified key performance and classification characteristics.
This paper is a short overview of results the two-year development work, which Final Report published by the European Commission in 2018.
Several attempts have been made in the past to develop a European harmonized testing and assessment method for façades before the European commission decided to publish a call for tender on the topic. A project consortium from five countries (Sweden, UK, France, Germany and Hungary) applied to the call for tender and was contracted to develop a European approach to assess the fire performance of façades. 24 sub-contractors and 14 stakeholder entities were part of the project.
The objective of the European project was to address a request from the Standing Committee of Construction (SCC) to provide EC Member States regulators with a means to regulate the fire performance of façade systems based on a European approach agreed by SCC. In addressing this objective, the project team was asked to consider a number of issues which are presented and discussed.
Recent facade fires worldwide have driven change in regulations for façade fire safety in different parts of the world. The Grenfell Tower fire 2017 in London triggered a thorough investigation of many aspects of the fire. One investigation was about the UK building regulations from Dame Judith Hackett 1,2. This investigation compares the UK with the situation other parts of the world.
Editorial façade fire safety
(2018)
This Special Issue of Fire and Materials brings together a collection of papers that were presented at the 2016 Interflam conference in the Fire & Facades session along with recent submissions to the Fire and Materials Journal that are very relevant to the Fire and Facades subject. Having attended the Interflam conference, all Fire and Materials Journal editors who attended realised the importance of this topic. We felt it important that this session content would both be reviewed and made available to a wider audience and that it was timely that we featured this increasing important topic in our journal. Accordingly, authors of selected papers were invited to update and extend their papers for journal submission, and other appropriate peer review papers subsequently submitted to the Journal were included in the collection.
As part of energy‐efficient renovations or for the construction of new buildings often external thermal insulation composite (ETIC) are used. In 2015, in Germany almost 37 million square meters were installed. But several fires involving ETIC systems with polystyrene foam (EPS) insulation in Germany led to an extensive discussion about fire safety of such systems. A collection initiated by the Frankfurt fire service of façade fires which include polystyrene insulation foam1 shows that more than two thirds of all reported fires started in front of buildings. In half of these fires burning waste containers were the first burning objects. Consequently, German building authorities called for tests of existing approved ETIC systems with EPS insulation in a fire Scenario representing a burning waste container. As these tests revealed weaknesses in the existing ETIC systems measures were introduced to enhance the systems. However, the recently introduced German test standard DIN 4102‐20 does not take These changes into account. The DIN test represents a fire where flames emerge an opening but is downscaled regarding the size of the fire load and therefore does not represent a fully developed fire in a room. In ETIC systems with EPS insulation, the render is an important factor for the fire performance of these systems as collapse of the render usually leads to very rapid fire development. Intermediate scale tests with ETICs specimens indicate that mechanical damages of the render weaken the System significantly. Challenges and possible measures to enhance fire safety of ETIC systems are discussed.
Die Bewertung des Zustandes und der Haftung von Putz und Fassadenelementen auf den darunterliegenden Bauwerksstrukturen ist eine häufig auftretende Fragestellung bei der Erhaltung und Instandsetzung von Bauwerken und Baudenkmälern. Hier müssen nicht nur wirtschaftliche und denkmalpflegerische, sondern auch sicherheitsrelevante Aspekte berücksichtigt werden. Fehlstellen und Ablösungen können, auch wiederholend, mit hoher Nachweisempfindlichkeit mit aktiven Thermografieverfahren geortet und unter bestimmten Voraussetzungen quantitativ bewertet werden. Dazu wird der zu untersuchende Bereich zunächst kurzzeitig (mehrere Minuten lang) erwärmt und anschließend die Abkühlung mit einer Infrarotkamera aufgezeichnet. Systematische Untersuchungen an Probekörpern mit einer Vielzahl unterschiedlicher Fehlstellen unterhalb von Kalkputz, Fliesen und Klinkerriemchen zeigen, dass die Fehlstellen sowohl mittels künstlicher Erwärmung durch einen Infrarotstrahler als auch mittels natürlicher Erwärmung durch die Sonne detektiert und charakterisiert werden können. ---------------------------------------------------------------------------------------------------------------------------------------
The evaluation of condition and adhesion of plaster and façade elements to the underlying building structure is a common issue in the maintenance and repair of buildings and monuments. Here not only economic and preservation, but also safety relevant aspects have to be considered. Voids and delaminations can be detected repeatedly with high sensitivity using active thermography methods. Under certain conditions, also a quantitative evaluation is possible. The area under investigation has to be heated up for a short time (up to several minutes). Subsequently, the cooling down is recorded using an infrared camera. Systematic studies on test specimens with a variety of defects below lime plaster, tiles and brick tiles show that the defects can be detected and even characterized both by means of artificial heating using an infrared heater, as well as by natural solar heating.