Non-destructive evaluation (NDE) of composites: using ultrasound to monitor the curing of composites
(2013)
Typical composite materials for lightweight construction consist of a fibre (glass or carbon) reinforced thermosetting matrix. The impregnation of the fabric is made with liquid resin – usually epoxy resin or unsaturated polyester resin are used. The main processing methods are resin transfer moulding (RTM) and prepreg technology often used in combination with autoclave curing. After shaping, the resin must be cured. The final properties of the produced parts depend on the curing degree and the final glass transition temperature. Analytical methods and the use of ultrasound for online cure monitoring in the manufacturing process are introduced. Examples for the application of ultrasonic cure monitoring for the production of composite parts for traffic systems are also covered.
The method for the determination of compression set values with a Dynamic Mechanical Analysis (DMA) setup at low temperatures, which was presented previously, allows a much faster and readily automated procedure than the standardized compression set test according to ISO 815-2. This method is applied to a series of different elastomeric materials that are commonly used for sealing applications. The results of the compression set test are compared with results from thermal analysis to allow an in depth comparison of the material behaviour at low temperatures.
Furthermore, a comparison between two EPDM materials is presented. These materials show very similar properties determined by thermo analytical methods such as Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) but differ clearly in their compression set behaviour. This comparison shows the importance and value of information of the compression set test in addition to thermal analysis to judge the behaviour of sealing materials and confirms the relevance of the new compression set test method for the investigation of low temperature properties of elastomers.
Elastomers are widely used as the main sealing materials for containers for low and intermediate level radioactive waste and as an additional component to metal seals in spent fuel and high active waste containers. The safe encapsulation of the radioactive container inventory has to be guaranteed according to regulation and appropriate guidelines for long term storage periods as well as for temperatures as low as -40°C during transport. Therefore, the understanding of failure mechanisms that lead to leakage at low temperatures is of high importance. It is known that the material properties of elastomers are strongly temperature dependent. At low temperatures, this is caused by the rubber-glass transition (abbreviated: glass transition). During continuous cooling, the material changes from a rubber-like entropy elastic to a stiff energy elastic behaviour, which allows nearly no strain or retraction. Hence, rubbers are normally used above their glass transition, but the minimum working temperature limit is not defined precisely; this can cause problems during the above noted applications. Therefore, the lower operation temperature limit of elastomer seals must be determined in dependence of the material properties. Differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) are combined with standardised measurements to determine the compression set according to ISO 815. To reduce the test time of the standard tests, a faster technique than normally used was developed. Additionally, the breakdown temperature of the sealing function of complete O ring seals was measured in a component test set-up to compare it with the results of the other tests. The experimental set-up is capable of measuring the leakage rate at low temperatures by the pressure rise method. A fluorocarbon rubber (FKM) was selected for this investigation as it is often used for radioactive waste containers. The materials (seals and test sheets) were purchased from a commercial seal producer.
Rubber is widely used as sealing material in various applications. In many fields the sealing function at low temperatures is necessary. Therefore the understanding of failure mechanisms is of high importance. Rubbers are normally used above their glass-rubber transition region but the minimum working temperature limit is not defined precisely. Therefore the lower operation temperature limit of rubber seals should be determined in dependence of the material properties. The results of Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) are combined with the results of the standardized compression set according to ISO 815 respectively a modified test using the DMA equipment.
The temperature dependences of dielectric permittivity and elastic modulus of poly(vinylidene fluoride - hexafluoropropylene) (P(VDF-HFP)) are compared and explained by use of structural data obtained by differential scanning calorimetry and X-ray analysis. Special emphasis is put on the effect of uniaxial stretching which renders the polymer ferroelectric. It is shown that dielectric and mechanical relaxations at the glass transition (aa relaxation) are closely related and not significantly affected by stretching. It is further confirmed that stretching destroys the non-polar spherulitic crystalline structure and produces relatively small-sized polar crystallites. This manifests in the disappearence of the so-called ac relaxation which is associated to molecular motions within the spherulitic crystalline lamellae. However, there are discrepancies between dielectric and mechanical losses above the glass transition which point towards a still not described structural transition.
A new method for the evaluation of the low temperature properties of rubber materials is presented. The method emulates the standardized compression set measurement, which is frequently used for sealing materials, but can be performed within a considerably shorter time. The results are compared with the standard test and found to be qualitatively the same. Slight differences are discussed on the basis of the differences in the measurement procedures. Further data evaluation is done by fitting functions to describe the material behaviour.
The dielectric and dynamic mechanical behaviour of bi-stretched non-treated and annealed semicrystalline poly(ethylene 2,6-naphthalene dicarboxylate) (PEN) films are studied as a function of different morphologies obtained by thermal treatments at temperatures close to the melting temperature of a semicrystalline film. Differential scanning calorimetry (DSC) shows that the glass transition temperatures do not change significantly with the thermal treatment for bi-stretched films. However, the melting temperatures and the degree of crystallinity increase with the value of annealing temperature. Both dielectric relaxation spectroscopy (DRS) and dynamic mechanical analysis (DMA) display three relaxation processes. In order of decreasing temperature, can be observed: the ?-relaxation due to the glass transition, the ?*-process assigned to cooperative molecular motions of the naphthalene groups which aggregate and the ?-relaxation due to local fluctuations of the carbonyl groups. The ?-relaxation process shifts to higher temperatures for the 250 and 260 °C treated bi-stretched semicrystalline samples compared to the sample thermally treated at 240 °C according to DRS data but shifts to lower temperatures according to the DMA measurements for the three annealed samples. This discrepency results from the different sensitivity of each methods with regards to the release of orientation. At a fixed frequency the temperature associated to ?*-relaxation is lower for the non-treated bi-stretched semicrystalline samples than for the treated ones using DMA but no difference can be seen in DRS. The associated apparent activation energies are rather high which suggest cooperative motions. It is assumed that the orientation of the samples prevents coupling between the naphthalene groups due to the stretched chain configuration in the amorphous phase. The activation energy for the ?-process given by DRS is independent of the thermal treatment and the value agrees with those found for poly(ethylene terephthalate) (PET) and amorphous PEN. Evidence of the decrease of orientation in the sample with thermal treatment can be seen via the onset of mobility, both by DRS and DMA. Thus, the orientation induces a greater change of properties compared to the crystalline samples obtained from the thermal treatment of an amorphous sample. Finally, a three phase model is proposed since there is evidence of a rigid amorphous phase present in PEN biaxially stretched samples which was favoured by the dependence of dielectric relaxation strengths on the degree of crystallinity for the ?*- and ?-relaxation.