How much information do we need? A reflection of the correct use of real defects in POD-evaluations
(2016)
To evaluate the capability of a non destructive testing system the “truth” of the used defects is essential. But what exactly is the truth of a real defect? And how much information is usable for the study? This presentation gives an overview about an advanced use of multiple metallographic cuts for the POD evaluation. In the presentation an approach is shown where information of metallographic studies are reconstructed and weighted to gain the essential information about real defects and which information are important for the detection with radiographic testing equipment. Furthermore, different connection points are discussed were additional knowledge from simulation and artificial defects can be used to gain additional certainty for the result of the evaluation. The methodology is used for the evaluation for the digital radiographic testing system for the testing of electron-beam welds, which is one possible choice to seal the Finnish copper canisters for the final deposit of spent nuclear fuel.
Der Stand der Technik beim digitalen Filmersatz in der Gussteilpruefung in Giessereien wird betrachtet.Eine Reihe von Normen fuer den Ersatz des Roentgenfilms durch neue digitale Detektoren wurde in den letzten Jahren veroeffentlicht. Die verschiedene Fehlertypen werden mit Fehlerkatalogen bewertet, die ebenfalls digital verfuegbar sind. Die Bildverarbeitung gestattet eine einfachere Bewertung der Anzeigen. Eine automatische Bewertung von Gussteilen durch den Computer erlaubt vollautomatische Anlagen, die 10 000 Teile pro Tag pruefen.
Since decades the evaluation of flaw indications on radiographs from welds or castings are based on well accepted reference film catalogues from organizations like IIW (weldments), ASTM (castings) or DGZfP (D5 recommendation on heavy steel castings). Today, the transformation of classical film radiography to the digital world is in full progress. Some ASTM standards do not permit the evaluation of digital radiographs in reference to film catalogues. Therefore, these reference film catalogues have to be converted into the digital age too. BAM is supporting this transition by high definition film scanning. The result is a corresponding reference image catalogue. The different standard organizations selected different ways to distribute the digital data. ASTM used high definition film scanning at 10 μm pixel size and distribution of a huge amount of high-res data via DVD. The user sub-samples these high-res data during catalogue import to the resolution of his system. The comparison is done by synchronized image viewing on the computer work station. IIW recently decided to distribute their ISO 5817 reference images installed on tablets, which are used for image viewing too. The tablet image has to be compared with the digital image on the system monitor. DGZfP transformed their D5 reference radiographs into a PDF for monitor viewing. This is the simplest and cheapest solution, but still allows the full usage of the catalogue in the digital era. The status of ongoing work in progress will be discussed.
In situ crack detection in the mushy zone and the solid weld of a gas tungsten arc (GTA) weld using X-ray imaging during welding is a new research area for NDT inspection. Usually, NDT flaw detection is done after the complete solidification of the weld seam. In this paper, we present the use of real-time radiography with a minifocus X-ray source (YXLON X-ray tube Y.TU 225-D04) and a 75μm pixel size digital detector array (Dexela 1512) for the acquisition of 2D radiographic images by a sequence of exposures with time intervals of 80 ms for hot crack detection during single pass bead-on-plate GTA welding of 3 mm thick plates of aluminium alloy AlMgSi (6060). An analysis of the crack distribution in the weld sample is conducted from the acquired 2D radiographs and its corresponding 3D volumetric reconstruction achieved by linear coplanar digital laminography.
This in situ approach opens new possibilities in the field of hot crack research by having the direct information of both the crack initiation and growth and its correlation to the welding parameters.