A new technique for optical fiber defect detection using Brillouin distributed fiber optic sensor (DFOS) has been proposed and experimentally demonstrated in this paper. This technique is based on stimulated Brillouin scattering (SBS), which offers three wave interaction in single mode optical fiber (SMF -10 μm/125 μm acrylic coated fiber). The nonlinear effect of SBS is manipulated to locate the defect in optical fiber using distributed sensing technology. Various kind of defects may be present in optical fibers. This paper details a case study on observation of a defect, which manifests its presence in certain temperature values. The detail of defect detection through distributed fiber sensor using the SBS has been brought out. SBS is sensitive to temperature and strain. In order to study the effect of defect in distributed fiber sensor as function of temperature and strain, the distributed pre-strained and unstrained optical fiber is subjected to temperature variation and corresponding measurements are obtained with Brillouin optical time domain analyser (BOTDA). This technique enables the utilization of Brillouin parameters, such as decreased amplitude, frequency and increased linewidth in the defect region of the fiber length. The fiber defect location can be determined with spatial resolution accuracy of less than 50 cm of using BOTDA technique.
Concept for investigating mechanical and thermal impacts on distributed subsurface gas monitoring
(2016)
A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO 2 gas storage sites in near real time.
Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas Distribution behavior. In this paper, we briefly describe the setup of a CO 2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m² test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.