- Flash thermography (2)
- Round robin test (2)
- Active thermography (1)
- CFK (1)
- CFRP (1)
- Energy dissipation (1)
- Energy sensor (1)
- Flash excitation (1)
- Flash lamp (1)
- Flat bottom holes (1)
- Infrared imaging (1)
- Lock-in Thermografie (1)
- Lock-in thermography (1)
- Metal (1)
- Metals (1)
- Multi-parameter POD (1)
- NDT (1)
- Non-destructive testing (1)
- Nondestructive testing (1)
- Numerical simulation (1)
- On-site inspection (1)
- Phase measurement (1)
- Polymers (1)
- SNR (1)
- Signal-to-noise ratio (1)
- Solar excitation (1)
- Standardisierung (1)
- Structural health monitoring (1)
- Thermal imaging (1)
- Ultraschall (1)
- optical excitation (1)
- standardization (1)
- ultrasonic excitation (1)
Probability of detection analysis of round robin test results performed by flash thermography
(2016)
Within the scope of a standardisation research project, a flash thermography round robin test that evaluates reliability, comparability and efficiency of different testing situations was performed. Data recorded at metal test specimens with flat bottom holes (FBHs) were analysed by calculating the signal-to-noise ratio (SNR) of the defect signatures in the thermograms as well as in the phase images as a function of defect parameters. A new multi-parameter probability of detection (POD) model was developed, where an â versus a continuous signal analysis was based on the linear relationship between the SNR and a multi-parameter a. This linear relationship was verified by comparison to data obtained from an analytical model that is considering lateral thermal heat diffusion as well as to data obtained by numerical simulation. The resulting POD curves for the thermograms and phase images give an estimation for the detectability of the FBHs with known geometry in steel using different equipment and obtained by different participants. By comparing the SNRs of FBHs with similar geometries, this POD model was transferred to aluminium and copper as well.
Comparison of quantitative defect characterization using pulse-phase and lock-in thermography
(2016)
Using optical excitation sources for active thermography enables a contactless, remote, and non-destructive testing of materials and structures. Currently, two kinds of temporal excitation techniques have been established: pulse or flash excitation, usingmostly flash lamps; and periodic or lock-in excitation, using halogen lamps, LED, or laser arrays. From the experimental point of view, both techniques have their advantages and disadvantages. Concerning the comparison of the testing results of both techniques, only very few studies have been performed in the past. In this contribution, the phase values obtained at flat bottom holes in steel and CFRP and the spatial resolution measured at crossed notches in steel using flash and lock-in excitation are compared quantitatively.
Comparison of concepts for a point-shaped energy density detector after flash lamp excitation
(2016)
The paper describes investigations and Research work in order to develop a simple sensor for the quantification of spectral broadband energy Dissipation of flash lamps at any point in space. Such Flash lamps are often used as energy source during active thermography testing (TT). Here, the temperature transient of the sensor surface has to be recorded by the infrared camera that is already present. During the following data evaluation, the energy input into the investigated specimen can be determined. Two opposite concepts were considered: thermal thick and thermal thin probes. The direct comparison shows advantages for thermal thick probes based on the physics of thermal balance processes.
This study evaluates whether subsurface features in rotor blades, mainly made of Glass Fibre Reinforced Plastics (GFRP), can generally be detected with ‘‘solar thermography”. First, the suitability of the sun is tested for acting as a heat source for applying active thermography on a 30 mm thick GFRP test specimen. Second, a defective rotor blade segment is inspected outdoors under ideal natural conditions using the sun as excitation source. Additionally, numerical FEM-simulations are performed and the comparability between experiment and simulation is evaluated for outdoor measurements.
Active thermography with lock-in excitation is a non-destructive testing method that is also feasible for testing of carbon fiber reinforced polymers (CFRP). For validating the method extensive investigations were done during a research project in order to advance a standardization process.
The most important parameters of optical and ultrasonic excitation thermography were investigated. For example, the appropriate selection of spectral sensitivity of the used infrared camera systems is important for recording undisturbed thermal signals. Regarding excitation,
influences of excitation power and ultrasonic frequency were studied. Furthermore, material parameters such as CFRP layup are known for strongly affecting the results of
measurement.
Within the scope of a DIN INS project, a flash thermography round robin test that evaluates reliability, comparability and efficiency of different testing situations is organized. The results give information about the detectability of defects e.g. by their size and depth, the evaluation method and by the materials used. Besides, the influence of equipment and parameters used by the participants on the results were analysed. All of the quantitative results as well as the feedback given by the participants will be presented in a DIN committee in order to contribute to a flash thermography standard.