Filtern
Erscheinungsjahr
- 2016 (7) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (7) (entfernen)
Sprache
- Englisch (7)
Schlagworte
- Adhesive bond (1)
- Application (1)
- Brillouin Optical Time Domain Analysis (1)
- Brillouin optical time domain analysis (1)
- Brillouin scattering (1)
- Coherent optical time-domain reflectometry (C-OTDR) (1)
- Cytop (1)
- Distributed sensor (1)
- Fiber Bragg gratings (1)
- Fiber characterization (1)
- Fiber optics sensors (1)
- Fiber-optic sensor (1)
- Fiber-optic speckle interferometry (1)
- Gamma radiation (1)
- Humidity induced annealing (1)
- Microstructured fibers (1)
- Molecular alignment relaxation (1)
- Monitoring (1)
- Optical fiber (1)
- Optical fiber sensor climatic stability (1)
- Optical fiber sensors (1)
- Perfluorinated polymer optical fibers (1)
- Polymer optical fibers (1)
- Polymers (1)
- Radiation-induced attenuation (1)
- Remote acoustic emission sensing (1)
- Standard (1)
- Stimulated Brillouin scattering (1)
- Strain (1)
- Structural health (1)
- Temperature (1)
- Thermal annealing (1)
- distributed sensor (1)
- optical fiber sensor (1)
Bond monitoring in temperature dependent applications using Brillouin optical time domain analyser
(2016)
Adhesive bond has to be evaluated for its integrity over a range of temperature. Adhesive is being used to bond the sensors with structures. There is no validated technique to test its performance. In this paper, we propose a Brillouin Optical Time Domain Analyzer (BOTDA) based methodology to detect temperature-induced adhesive bond failure below room temperature using distributed fiber optic sensor. The differential coefficient of thermal expansion of the structure and fiber sensor can lead to bond failure at low temperature. Optical fiber impregnated in the structure will experience differential temperature/strain due to debond of the adhesive. This leads to the frequency and amplitude decomposition of the Brillouin spectra. This is a good indication for real-time monitoring of the integrity of a bond.
A new technique for optical fiber defect detection using Brillouin distributed fiber optic sensor (DFOS) has been proposed and experimentally demonstrated in this paper. This technique is based on stimulated Brillouin scattering (SBS), which offers three wave interaction in single mode optical fiber (SMF -10 μm/125 μm acrylic coated fiber). The nonlinear effect of SBS is manipulated to locate the defect in optical fiber using distributed sensing technology. Various kind of defects may be present in optical fibers. This paper details a case study on observation of a defect, which manifests its presence in certain temperature values. The detail of defect detection through distributed fiber sensor using the SBS has been brought out. SBS is sensitive to temperature and strain. In order to study the effect of defect in distributed fiber sensor as function of temperature and strain, the distributed pre-strained and unstrained optical fiber is subjected to temperature variation and corresponding measurements are obtained with Brillouin optical time domain analyser (BOTDA). This technique enables the utilization of Brillouin parameters, such as decreased amplitude, frequency and increased linewidth in the defect region of the fiber length. The fiber defect location can be determined with spatial resolution accuracy of less than 50 cm of using BOTDA technique.
We present a demodulation method that partially compensates for the nonlinear and random transfer function of fiber-optic direct detection coherent Rayleigh optical time-domain reflectometry (C-OTDR). Specifically, the proposed method is shown to improve the detection of small amplitude, high frequency dynamic optical fiber strain as it occurs in acoustic emission sensing. The method is applicable provided that the dynamic fiber strain to be sensed is known to affect a longer section of sensing fiber in a spatially homogeneous way. It is shown that this knowledge can be used to extract more quantitative information from the measured C-OTDR signal by averaging signal components from the affected fiber section in a suitable and efficient way. The theoretical basis of the method is developed and supporting experimental results are presented.
Measurement and data recording systems are important parts of a holistic Structural Health Monitoring (SHM) system.
New sensor technologies such as fiber-optic sensors are often used; however, standards (or at least guidelines) are not yet available or internationally approved. This lack in standardization makes the acceptance of FOS technologies in complex SHM systems substantially difficult. A standard family for different FOS technologies is therefore being developed that should help to design SHM systems in an optimal way. International standardization activities take place in several standardization bodies such as IEC and ASTM, and within SHM societies such as ISHMII.
The paper reports on activities in standardization of fiber-optic sensors, on results already achieved, and on newly started projects. Combined activities of fiber sensor experts and SHM experts from Civil Engineering are presented. These contributions should help owners of structures as well as developers of sensors and monitoring systems to select effective and validated sensing technologies. Using these standards, both parties find recommendations how to proceed in development of SHM systems to evaluate the structural behavior based on e.g. standardized fiber optic sensors, and to derive necessary measures, e.g. the optimal maintenance strategy.
The paper presents the first complex study of Gamma radiation effects on a low-loss perfluorinated polymer optical fiber (PF-POF) based on Cytop® polymer. Influence of gamma radiation on fiber’s optical, mechanical and climatic performance is investigated. The radiation-induced attenuation (RIA) in the visible and near-infrared region (0.4 μm-1.7 mm) is measured and its origins are discussed. Besides attenuation increase, radiation is also shown to decrease the thermal degradation stability of the fiber and to increase its susceptibility to water. With regard to complex fiber transmission performance upon irradiation, the optimal operation wavelength region of PF-POF-based systems intended for use in Radiation environments is determined to be around 1.1 μm. On the other hand, the investigated fiber holds potential for low-cost RIA-based optical fiber dosimetry applications with sensitivity as high as 260 dBm⁻¹/kGy in the visible region.
Here we present the fabrication of a solid-core microstructured polymer optical fiber (mPOF) made of polycarbonate (PC), and report the first experimental demonstration of a fiber Bragg grating (FBG) written in a PC optical fiber. The PC used in this work has a glass transition temperature of 145°C. We also characterize the mPOF optically and mechanically, and further test the sensitivity of the PC FBG to strain and temperature. We demonstrate that the PC FBG can bear temperatures as high as 125°C without malfunctioning. In contrast, polymethyl methacrylate-based FBG technology is generally limited to temperatures below 90°C.
A systematic study of annealing behavior of drawn PMMA fibers was performed. Annealing Dynamics were investigated under different environmental conditions by fiber longitudinal shrinkage monitoring. The shrinkage process was found to follow a stretched exponential decay function revealing the heterogeneous nature of the underlying molecular dynamics. The complex dependence of the fiber shrinkage on initial degree of molecular alignment in the fiber, annealing time and temperature was investigated and interpreted. Moreover, humidity was shown to have a profound effect on the annealing process, which was not recognized previously. Annealing was also shown to have considerable effect on the fiber mechanical properties associated with the relaxation of molecular alignment in the fiber. The consequences of fiber annealing for the climatic stability of certain polymer optical fiber-based sensors are discussed, emphasizing the importance of fiber controlled pre-annealing with respect to the foreseeable
operating conditions.