Filtern
Erscheinungsjahr
- 2016 (3) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (3) (entfernen)
Schlagworte
- Damage detection of bridges (1)
- ECD-Aktorschicht (1)
- Faseroptik-Sensoren (1)
- Fiber bragg grating (1)
- Lagrange multiplier test (1)
- Magnetic field (1)
- Magnetostrictive metal coating (1)
- Monitoring (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- PVD-Haftfestigkeit (1)
- Self-diagnostic fiber optical sensor (1)
Durch faseroptische Sensoren können Bauteile im Einsatz kontinuierlich überwacht und frühzeitig Informationen über Materialveränderungen gewonnen werden. Mittels einer magnetostriktiven Aktorschicht, welche den Sensor umhüllt, kann nun auch die korrekte Sensorfunktion jederzeit kontrolliert werden. Als Aktorschicht eignet sich galvanisch abgeschiedenes reines Nickel oder Nickel-Eisen in der Zusammensetzung 50:50. Um diese haftfest mit dem Sensor zu verbinden wurde ein ECD/PVD-Kombinationsschichtsystem entwickelt. Die mechanischen Eigenschaften der ECD-Schicht können sowohl mit einer auf die Fasergeometrie angepassten instrumentierten Eindringprüfung als auch einem 2-Punkt-Biegeversuch bestimmt werden.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Innovative structural damage detection of bridges by least squares adjustment with constraints
(2016)
Long-term monitoring of bridges requires the early detection of spreading damage because very often the damage is not really visible. For many decades engineers and scientists relayed on dynamic methods especially modal ones. However, after fundamental tests by the U.S. FHWA in 1993, it became evident that more successful methods should be developed, but no innovation really happened. A substantial innovative detection method started four years ago from Lagrange Multiplier Testing which eventually resulted in experimental verification based on measurement of deflection and curvature of the bridge beam and together the methodological combination of both.