For decades, the low-strain impact integrity testing using a hammer blow is well established as a method of quality assurance for various pile types. However, this method has its limitations. Our research and development focuses on improving the excitation signal using a shaker system in contrast to the standard hammer method. Another approach is to increase the amount of sensors used during testing. The purpose is to identify the direction of wave propagation which gives advantages under difficult conditions, such as piles below structures.
Pile integrity testing (PIT) using a shaker system was performed on two 11 m long piles of 90 cm in diameter. While one pile was intact, the other one showed a flaw at approx. 3.5 m below pile top, which was confirmed by standard PIT in 2012. A logarithmic sweep between 500 Hz and 1 KHz of 0.1 s was used as the input signal, being vertically injected into the pile. Prior to that, simulations on similar pile geometries showed that the depth of the pile toe as well as flaws within the pile can be extracted by applying regularized deconvolution. The result is the impulse response in the time domain.
The application of deconvolution on the measured signals shows that it is possible to identify the pile length but it is more difficult to clearly extract the flaw’s position in the pile. Additional digital signal processing techniques and the improvement of the regularized deconvolution method as well as the experimental setup need to be investigated.
Another way to improve the PIT method is to use a multichannel sensor arrangement. By arranging several accelerometers vertically along the accessible part of the pile shaft, it is possible to distinguish between downward and upward traveling waves. Furthermore, it is possible to estimate the unknown wave speed, which gives the possibility of more accurate pile length calculations. The method was evaluated successfully during a measurement campaign of a slab foundation with subjacent piles. In 20 of 28 cases the pile length could be detected accurately.
The ultrasonic echo technique is a frequently used method in non destructive testing for geometry Determination of concrete building elements. Important tasks are thickness measurements as well as the localization and characterization of built-in components and inhomogeneities.
Currently mainly the synthetic aperture focusing family of techniques (SAFT) is used for imaging. These algorithms have difficulties in imaging steeply dipping interfaces and complicated structures such as steps and lower boundaries of voids. As an alternative two geophysical migration methods, pre-stack Kirchhoff depth migration and pre-stack Reversetimemigration (RTM)were tested in this paper at a reinforced concrete foundation slab. The slab consists of various reinforcement contents, different thicknesses and two pile heads.
In a first step, both methods were evaluated with synthetic 2D data. In the second step, ultrasonic measurement data recorded with shear wave transducers on a line profile on the foundation slab were processed. The use of an automatic scanner simplified the measurements. A comparison of the geophysical migration results with those of SAFT shows, in particular for RTM, a significant improvement in the Imaging of the geometry of the foundation slab. Vertical borders were reconstructed and the location and structure of the lower boundary of the foundation slab were reproduced better. Limitations still exist in imaging the piles below the slab.