Carrying out dimensional measurements by CT means assessing coordinates in space. CT must therefore be treated as a coordinate measuring technique similar to optical or tactile Coordinate Measuring Machines (CMMs). The well-established standards and guidelines for the acceptance- and verificationtesting of CMMs require the use of calibrated reference standards to achieve measurement machine characteristics.
Hence, transferring these concepts from coordinate metrology to CT, a dedicated CT-specific reference standard was designed, manufactured and calibrated using a tactile CMM. For comparison purposes, a CAD model was created by reverse engineering using the calibration data. The calibrated model was fed into a virtual CT and the measurement process was simulated. The reference standard was measured by micro-CT.
By comparing the characteristics of the measurement output of CT and the output gained from simulation, the influences of measurement artefacts can be judged, for the first time, in analogy to existing Guidelines of coordinate metrology.
Micro gears are applied in an increasing quantity in many applications. Therefore, precise measurements are of growing importance to ensure their quality. This contribution describes the measurement of gears of a micro planetary gear set with a tactile probe, a tactile-optical probe, an optical sensor, and computed tomography (CT). For the tactile measurements, a high precision piezoresistive microprobe was used. A so-called fiber probe was applied for tactile-optical measurements. This probe applies image processing to determine the position of the tactile probing element. For all tactile and tactile-optical measurements, single point probing was used. The optical measurements were carried out with an imaging sensor based on focus variation. Due to limited accessibility, on some gears not all regions could be measured by the optical sensor and the tactile-optical probe. In contrast to this, with CT the whole part could be measured with high point density. We used a micro-CT system and carried out measurements with Synchrotron-CT. All the sensors used deliver measurement data in Cartesian coordinates. It is a challenge to transfer these data into coordinates in which gear parameters are defined. For this, special attention must be paid to the determination of the gear axis and to the orientation of the teeth. The applied procedures are detailed for different micro gears. The comparison between data of different measurements was carried out successfully. The deviations between the CT data and the tactile or tactile-optical data lie in the range of only a few micrometers.
Biocompatible materials such as porous bioactive calcium phosphate ceramics or titanium are regularly applied in dental surgery: ceramics are used to support the local bone regeneration in a given defect, afterwards titanium implants replace lost teeth. The current gold standard for bone reconstruction in implant dentistry is the use of autogenous bone grafts. But the concept of guided bone regeneration (GBR) has become a predictable and well documented surgical approach using biomaterials (bioactive calcium phosphate ceramics) which qualify as bone substitutes for this kind of application as well. We applied high resolution synchrotron microtomography and subsequent 3d image analysis in order to investigate bone formation and degradation of the bone substitute material in a three-dimensional manner, extending the knowledge beyond the limits of classical histology. Following the bone regeneration, titanium-based implants to replace lost teeth call for high mechanical precision, especially when two-piece concepts are used in order to guaranty leak tightness. Here, synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in these kind of highly attenuating objects. Therefore, we could study micro-gap formation at interfaces in two-piece dental implants with the specimen under different mechanical load. We could prove the existence of micro-gaps for implants with conical connections as well as to study the micromechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential issue of failure, i. e. bacterial leakage which can induce an inflammatory process.
Investigations of corrosion on small cathodes in reinforced concrete - observations and suggestions
(2009)
Corrosion of steel reinforcement in concrete exposed to chloride containing environments is a serious
problem in civil engineering practice. The standards and guidelines contain only minimum
requirements regarding concrete quality and concrete cover. In very critical cases, for example the
ingress of chlorides, the application of different coatings is currently the only possibility to protect the
reinforced concrete structures. In this case the modelling of reinforcement corrosion would be more
practical. One sub-project of a DFG-research project (FOR 537) is currently performed at the Federal
Institute for Materials Research and Testing (BAM). Aim of the sub-project is the description of
corrosion propagation and the characterization of the corrosion on specimens with small cathodes by
electrochemical parameters. The electrochemical parameters are determined by suitable
electrochemical measurements, considering concrete parameters as well as different environmental
conditions.