Due to their increasing energy density, lithium-ion-batteries (LIBs) play a key role in the traffic energy transition. Regarding their safety behavior, the main challenge of LIB-cells remains the thermal runaway (TR) process. In situ/operando investigations of the TR on commercial cells is possible with radiographic and computer tomographic measurements. Nonetheless, high resolution visualization of the TR persists as a challenge due to the high progression speed of the TR-process itself. Generally, performing abuse tests at cryogenic temperatures allows to slow down or even prevent the TR. Nevertheless, not all abuse methods are suitable for TR investigations at low temperatures. Nail penetration is an appropriate option, however, contains numerous unknown parameters and therefore suffers regarding reproducibility.
Herein, a self-developed high precision nail-penetration-setup is introduced, approaching the necessary mechanically reproducibility with controlled temperatures down to -190°C. The setup allows the preparation of critically abused, however, at cryogenic temperatures stable LIB-cells. These cells were controlled rethermalized to room temperature during synchrotron x-ray computer tomography (SXCT) with a pixel size up to 0.7 μm. During this measurement, the temperature and voltage of the cell is monitored allowing the visualization of the initial internal cell reactions. This study reveals the relation between internal reactions and cell voltage. Finally, the developed set-up enables in-depth analysis of thermal runaway behavior down to material level for various commercial battery cells in the future.
Next to performance features, safety aspects of lithium-ion batteries (LIBs) are a crucial research field. The abuse/misuse of a LIB can trigger a chain of exothermic reactions on cell level. Hence, the cell temperature increases dramatically, causing the so-called thermal runaway (TR). Moreover, the TR of one cell can initiate the TR of adjacent cells leading to a TR-propagation. Due to the risk of a TR, special measures need to be applied while handling, storing, and transporting batteries. According to current transport regulations, all different types of lithium-ion and lithium metal cells/batteries (by means of cell format, cathode chemistry, etc.) require the same transport conditions regardless of the intensity of their reaction during abuse tests. To allow more differentiated transport requirements, the United Nations (UN) Subcommittee Transport of Dangerous Goods created an Informal Working Group (IWG) on the topic of a hazard-based classification of LIBs. BAM is one of nine laboratories working on the development of a respective classification scheme including appendant test protocols.
Herein, we discuss the latest results of our safety tests on commercial LIB-cells employing the test protocols developed in the UN-IWG. Single cell tests are analysed regarding different hazardous features during the TR, e.g., cell temperature, flame occurrence, and gas amount. Next to the general occurrence of a propagation, the propagation speed is analysed by propagation tests. In total, the presented results are gathered from over 200 tests. Next to the classification of the tested cells, the data set obtained is analysed in respect to the cells’ key features, such as cell energy, state of charge and cathode type. Generally, the presented results can increase the overall understanding of the TR-mechanism supporting the design of advanced safety measures on cell level in the future.
Understanding the safety characteristics of aged Lithiumion
(Li-ion) batteries is essential for their effective
integration into second-life applications. The SafeLiBatt
project is a research initiative focused on evaluating
safety-related parameters of these batteries.
The presented study elucidates the impact of a cells’
state of health (SOH) on its safety behavior. Four highpower
pouch cells (Li-NMC622) were exposed to elevated
temperatures to achieve accelerated ageing. Subsequent
thermal abuse tests were utilized to assess crucial
parameters related to the thermal runaway (TR).
When compared to their non-aged (begin of life, BOL)
analogs, the aged cells implicated a TR-onset lowered by
about 10 – 20 K.
Lithium batteries are the key technology for the successful implementation of the energy transition. Nevertheless, the consequences of thermal runaway of lithium batteries pose the greatest safety risk. In particular, the transport of damaged lithium batteries poses special challenges in order to minimize the effects of thermal runaway. By developing a precision nail test rig, the positive effects of cooling damaged lithium batteries can be investigated and safe transport temperatures identified.
Introduction
Lithium-ion batteries (LIBs) are one key technology to overcome the climate crisis and energy transition challenges. Demands of electric vehicles on higher capacity and power drives research on innovative cathode and anode materials. These high energy-density LIBs are operated at higher voltages, leading to increased electrolyte decay and the current collectors' degradation. Even though this fundamental corrosion process significantly affects battery performance, insufficient research is being done on the aluminum current collector. Fast and convenient analytical methods are needed for monitoring the aging processes in LIBs.
Methods
In this work glow-discharge optical emission spectrometry (GD-OES) was used for depth profile analysis of aged cathode material. The measurements were performed in pulsed radio frequency mode. Under soft and controlled plasma conditions, high-resolution local determination (in depth) of the elemental composition is possible. Scanning electron microscopy (SEM) combined with a focused ion beam (FIB) cutting and energy dispersive X-ray spectroscopy (EDX) was used to confirm GD-OES results and obtain additional information on elemental distribution.
Results
The aging of coin cells manufactured with different cathode materials (LCO, LMO, NMC111, NMC424, NMC532, NMC622, and NMC811) was studied. GD-OES depth profiling of new and aged cathode materials was performed. Quantitative analysis was possible through calibration with synthetic standards and correction by sputter rate. Different amounts of aluminum deposit on the cathode surface were found for different materials. The deposit has its origin in the corrosion of the aluminum current collector. The results are compatible with results from FIB-EDX. However, GD-OES is a faster and less laborious analytical method. Therefore, it will accelerate research on corrosion processes in high energy-density batteries.
Innovative aspects
- Quantitative depth profiling of cathode material
-Monitoring of corrosion processes in high energy-density lithium-ion batteries
- Systematic investigation of the influence of different cathode materials