This contribution attempts to shed light on the application of POD analyses and measurement uncertainty calculations in nondestructive testing of concrete structures to provide useful and quality-assured information for reliability assessments of our built environment - with an emphasis on ground penetrating radar. It is shown that signal processing techniques affect POD analysis results to varying degrees, that measurement uncertainties are useful to validate PODs, and that the utilization of both POD analysis and measurement uncertainty calculations can pave the way to NDT-based reliability assessment, which will be exemplarily demonstrated in conclusion – generally aiming to derive those maintenance strategies and actions that are in line with actual demands.
This dataset contains raw data resulting from Impact-Echo measurements at the reference conrete block "Radarplatte", located at BAM (German Federal Institute for Materials Research and Testing). This specimen has been described in detail by Niederleithinger et al. (2021), who applied muon tomography, ultrasonic echo measurements, radar and X-ray laminography to visualize its internal structure.
The Impact-Echo method is based on the excitation of the zero-group-velocity frequency of the first symmetric Lamb mode of a plate-like structure, in order to assess its thickness. Numerous publication elaborate on Impact-Echo theory, examples are (Gibson and Popovics 2005, Schubert and Köhler 2008 , Abraham and Popovics 2010).
The measurements have been conducted using a setup that contains only commercially available components. The setup consists of an Olson CTG-2 concrete thickness gauge (Olsen Instruments, USA) for actuation and sensing and an 8-bit NI USB-5132 digital storage oscilloscope (National Instruments, USA) combined with the Echolyst software (Schweizerischer Verein für technische Inspektionen (SVTI), Switzerland) for data acquisition.
Measurements were conducted using a grid of 23x23 points with a spacing of 50 mm. At each point 8192 samples were recorded at a sampling rate of 1 MS/s.
The dataset contains the (X,Y) location in mm of the individual measurement points as well as the raw measurement data at those points.
The data is provided in the formats *.mir/*.mhdr (Echolyst), *.npy (Python) and *.mat (Matlab) and *.csv to ease the import in various post-processing tools.