Bringing isotopic spike calibration solutions for isotope dilution to a broader analytical community
(2000)
A comparison of high accuracy methods for the analysis of total sulfur in gas oils by three metrology institutes is described. The work contains a comparison of three different aspects of the analysis: sample digestion, instrumental measurement and isotope dilution strategies.
Thermal ionisation mass spectrometry (TIMS) in combination with high pressure asher (HPA) or Carius tube digestion has traditionally been used for such high accuracy analysis. However, this paper demonstrates that the faster, less laborious technique of ICP-MS in combination with microwave digestion is equally capable. Results from the comparison experiments show excellent agreement for fuel samples containing sulfur concentrations in the range 11200 µg g-1. This excellent agreement across the different sample preparation, measurement and isotope dilution techniques has been exploited in the certification of two new diesel fuel reference materials.
Comparative performance study of ICP mass spectrometers by means of U "isotopic measurements"
(2000)
The performance of four commercially available ICPMS instruments of three different types was compared by means of uranium "isotopic measurements". Examined were two quadrupole sector (different generation, different manufacturer), one single detector double focusing magnetic sector and one multiple collector double focusing magnetic sector instruments. The same samples of the IRMM-072 series were used under routine conditions to measure the 233U/235U and the 233U/238U ratios which, in these samples, vary over almost three orders of magnitude from ~ 1 to ~ 2 · 10-3. Within expanded (k = 2) uncertainties, good agreement was observed between the certified values and the data internally corrected for mass-discrimination effects. The magnitude of the evaluated uncertainties was different for each type of instrument. With the multiple collector instrument, expanded uncertainties varied from - 0.04% to- 0.24% for the 233U/235U ratio, and from - 0.08% to - 0.27% for the 233U/238U ratio. They were ~ 1 to 5 times larger with the single detector magnetic sector instrument, and ~ 10 to 25 times larger with both quadrupole sector instruments. With the multiple collector instrument, repeatability of the measurements seemed to be limited by the difficulty of correcting properly for instrumental background, whereas with the single detector magnetic sector instrument the counting statistics was the only limitation (on smallest ratios). Apparent mass-discrimination was clearly found to be larger but more reproducible (and hence easier to correct for) in the case of magnetic sector instruments than for both quadrupole sector instruments. If space charge effects were the main source of mass-discrimination for all instruments, these results are in contradiction with the hypothesis of the size of mass-discrimination decreasing with the acceleration voltage. With the single detector magnetic sector instrument in particular (when operated by changing the ion energy only), our results pointed at more than only one major source of mass-discrimination, with variable size depending on the ratios measured.
The present paper describes the contribution of the Institute for Reference Materials and Measurements to the certification of B, Cd, Mg, Pb, Rb, Sr, and U amount contents in a natural water sample, in round 9 of the International Measurement Evaluation Programme (IMEP-9). The analytical procedure to establish the reference values for B, Cd, Mg, Pb, Rb, Sr, and U amount contents was based on isotope dilution inductively coupled plasma-mass spectrometry used as a primary method of measurement. Applying this procedure reference values, traceable to the SI, were obtained for the natural water sample of IMEP-9. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations are described for all seven elements mentioned above. In order to keep the whole certification process transparent and so traceable, the preparations of various reagents and materials as well as the sample treatment and blending, the measurements themselves, and finally the data treatment are described in detail. Explanations focus on Pb as a representative example. The total uncertainties (relative) obtained were less than 2% for all investigated elements at amount contents in the pmol/kg up to the high 7mol/kg range, corresponding to low 7g/kg and mg/kg levels.
The development and implementation of a method for the certification of cadmium in blood samples at low ng g-1 and sub ng g-1 levels is described. The analytical procedure is based on inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. Two different sample digestion methods, an optimized microwave digestion procedure using HNO3 and H2O2 as oxidizing agents and a high-pressure asher digestion procedure, were developed and compared. The very high salt content of the digests and the high molybdenum content, which can cause oxide-based interferences with the Cd isotopes, were reduced by a chromatographic matrix separation step using an anion-exchange resin. All isotope ratio measurements were performed by a quadrupole ICP-MS equipped with an ultrasonic nebulizer with membrane desolvator. This sample introduction set-up was used to increase sensitivity and minimize the formation of oxides (less MoO+ interference with the Cd isotopes).
Because of the very low Cd concentrations in the samples and the resulting need to minimize the procedural blank as much as possible, all sample-processing steps were performed in a clean room environment. Detection limits of 0.005 ng g-1 Cd were achieved using sample weights of 2.7 g. The method described was used to re-certify the cadmium content of three different blood reference materials from the Community Bureau of Reference (BCR) of the European Commission (BCR-194, BCR-195, BCR-196). Cadmium concentrations ranged between ~0.2 ng g-1 and ~12 ng g-1. For these materials, SI-traceable certified values including total uncertainty budgets according to ISO and Eurachem guidelines were established.
New mathematical models with associated equations for isotope dilution mass spectrometry (IDMS)
(2004)
Vector models which progressively lead to a general model for isotope dilution mass spectrometry (IDMS) are presented for the case of two lsquomonitor isotopesrsquo and one blend involved. They enable one to find the boundary conditions for performing IDMS, and cover the cases of highly enriched isotopes, radioactive isotopes and ratios that are given with different denominator. The models identify the key measurements in their simplest form as well as the conditions which minimise the measurement effort and in some cases the propagated measurement uncertainties. The equations are discussed and compared with other published IDMS equations. Combined with discussion on fundamental aspects of IDMS, this results in an even more lsquogeneralrsquo but also more complex IDMS equation.
The feasibility of performing SI-traceable carbon isotope amount ratio measurements following conversion of carbon into CF4 was studied. A procedure for the direct fluorination of carbon with elemental fluorine was developed, and the conversion step was checked for losses, blank contributions, and the absence of systematic isotope effects. Gas chromatography was used to identify and quantify the gaseous fluorination products and to isolate CF4 from byproducts. After fluorination of graphite carbon, CF4 and perfluoroalkanes with up to six carbon atoms were observed as reaction products. Within an uncertainty of 10%, the graphite carbon was fully recovered in the gaseous carbon fluorides, with the main product being CF4 (80-90%) and C2F6 as the major byproduct. The fluorination and GC procedures were found to introduce an alteration not bigger than 0.03 ± 0.04 on the isotopic composition of CF4. Carbon blank contributions introduced during the fluorination procedure were below 0.5% relative to a typical sample of 4 mg of carbon. For two of the materials investigated, the carbon isotope ratios measured on a differential mass spectrometer were reproducible within a standard deviation of ~0.1 for several individual fluorinations. For these materials, the developed fluorination procedure is a straightforward process, which can be used as a foundation to establish SI-traceable measurements of carbon isotope amount ratios. However, for the third graphite material the formation of byproducts (C2F6-C6F14) was found to induce significant isotopic fractionation.
Calibrated values have been obtained for sulfur isotope abundance ratios of sulfur isotope reference materials distributed by the IAEA (Vienna). For the calibration of the measurements, a set of synthetic isotope mixtures were prepared gravimetrically from high purity Ag2S materials enriched in32S, 33S, and 34S. All materials were converted into SF6 gas and subsequently, their sulfur isotope ratios were measured on the SF5+ species using a special gas source mass spectrometer equipped with a molecular flow inlet system (IRMMs Avogadro II amount comparator). Values for the 32S/34S abundance ratios are 22.650 4(20), 22.142 4(20), and 23.393 3(17) for IAEA-S-1, IAEA-S-2, and IAEA-S-3, respectively. The calculated 32S/34S abundance ratio for V-CDT is 22.643 6(20), which is very close to the calibrated ratio obtained by Ding et al. (1999). In this way, the zero point of the VCDT scale is anchored firmly to the international system of units SI. The 32S/33S abundance ratios are 126.942(47), 125.473(55), 129.072(32), and 126.948(47) for IAEA-S-1, IAEA-S-2, IAEA-S-3, and V-CDT, respectively. In this way, the linearity of the V-CDT scale is improved over this range. The values of the sulfur molar mass for IAEA-S-1 and V-CDT were calculated to be 32.063 877(56) and 32.063 911(56), respectively, the values with the smallest combined uncertainty ever reported for the sulfur molar masses (atomic weights).
Isotope amount ratios of krypton were measured on subsamples from one large batch of high purity krypton separated from the atmosphere. Synthetic mixtures of enriched krypton isotopes were used to calibrate the measurements with small uncertainties. The result is a primary isotopic gas standard (PIGS) IRMM-2030 with certified values for isotope ratios, isotopic composition, and molar mass of krypton with small combined uncertainties uc, evaluated according to the ISO/BIPM Guide (GUM). It is commercially available from IRMM-Geel or from MESSER (Duisburg, D). The certified krypton isotope amount ratios in the PIGS IRMM-2030 are as follows: n(78Kr)/n(84Kr)=0.006 232 5(55), n(80Kr)/n(84Kr)=0.040 107(17), n(82Kr)/n(84Kr)=0.203 43(12), n(83Kr)/n(84Kr)=0.201 79(11), and n(86Kr)/n(84Kr)=0.303 205(59) with expanded uncertainty U=kuc and coverage factor k=2. The molar mass of Kr in this sample is M(Kr)=83.798 02(16) g/mol. These values are in good agreement with published measurements of atmospheric krypton but have smaller combined uncertainties and are calibrated by means of synthetic isotope mixtures. The values of the PIGS are traceable to the SI. Measurements of isotope amount ratios of krypton in other samples can be linked to SI using this PIGS.