Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
According to UN Test O.2, surprisingly, the polychlorosilanes hexachlorodisilane (HCDS), octachlorotrisilane (OCTS) and decachlorotetrasilane (DCTS) formally fulfill the criteria of the “test for oxidizing liquids”. This result is in contrast to the properties of polychlorosilanes that are described in the literature and those we have experienced in our own production.
By investigating the reaction products from the UN O.2 test reactor, using IR, Raman and XPS spectroscopy, it was shown that the results are not due to oxidizing properties of HCDS, OCTS or DCTS, but are caused by the specified test substance cellulose. To our knowledge, this is the very first substance class in which the reference substance oxidizes the test sample, instead of vice versa. This represents an important limitation of the internationally used UN Test O.2 for this substance class. The cause for this false-positive result is the known high degree of affinity of oxygen to silicon.
It is shown that the correctly executed UN Test O.2 produces false-positive results and that the polychlorosilanes do not have an oxidizing effect and, therefore, do not have to be classified as “oxidizing substances”.
Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
The mixture of ammonium nitrate (AN) prills and fuel oil (FO), usually called ANFO, is extensively used in the mining industry as a bulk industrial explosive. One of the major performance predictors of ANFO mixtures is the fuel oil retention, which is itself governed by the porosity of the AN prills. Standardised tests routinely used to assess oil retention face several important limitations; the first being the difficulty to cover the wide range of porosity contents and morphologies from different types of ammonium nitrate prills; the second being the inability to evaluate the closed porosity, which is an important factor regarding the sensitivity of the explosive to detonation. In this study, we present how X-ray computed tomography (XCT), and the associated advanced data processing workflow, can be used to fully characterise the structure and morphology of AN prills. We show that structural parameters such as volume fraction of the different phases and morphological parameters such as specific surface area and shape factor can be reliably extracted from the XCT data, and that there is a good agreement with the measured oil retention values. XCT can therefore be employed to non-destructively and accurately evaluate and characterise porosity in ammonium nitrate prills.
Testing of hazardous materials and evaluating their hazardous properties concerning transport, handling or use is essential for the prevention of incidents. For this purpose, test methods have been developed and published that are used worldwide today (European Union, 2008, United Nations, 2019). For the evaluation of test results their correct measurement is of importance. On basis of the interlaboratory tests carried out by BAM and PTB within the framework of the CEQAT-DGHS in the last years, it is shown that there is a need for improvement in all the test methods examined so far. In addition to the interlaboratory tests further quality measures are mandatory (ISO, 2017). For example, methods for verifying the test equipment used in the laboratories should be developed.
The development of a verification method is demonstrated using the test method UN Test N.5 as an example. This test method is used to evaluate substances which in contact with water emit flammable gases. The basic principle of the verification method is demonstrated by Lüth et al. (2019). Requirements and difficulties during this development are discussed.
This test procedure UN Test N.5 has now been modified at BAM so that it is possible to measure very small or large amounts of both flammable and/or toxic gases over a long period of time in a validated and verified test apparatus, utilizing the principle of a gas collector. This allows us to determine slow as well as fast gas evolution rates. The determination of the evolution rates (e.g. total gas amount or flow rate) of toxic gases is of special interest because of the ongoing discussion how to evaluate and quantify toxic gases which are formed from a substance due to contact with water. Up today no validated test procedure for the measurement of evolution rates for toxic gases is described. It is shown that the newly modified test method could help to solve this problem.
Prüfapparaturen zur Bestimmung sicherheitstechnischer Kennzahlen müssen präzise messen, um verlässliche Ergebnisse zu produzieren. Oftmals gibt es in der Methodenbeschreibung allerdings keine Informationen zu Messunsicherheiten o.ä.. In dem Vortrag werden Ringversuchsprogramme das CEQAT-DGHS beschrieben und aktuelle Arbeiten zu Verifizierungsverfahren von Messmethoden beschrieben.
CEQAT-DGHS Interlaboratory Test Programme for Chemical Safety - Need of Test Methods Validation
(2019)
Safety experts, manufacturers, suppliers, importers, employers or consumers must be able to rely on the validity of safety-related test methods and on correct test results and assessments in the laboratory. Via the eChemPortal lots of data from the REACH registration dossiers are available. However, the quality and correctness of the information remains in the responsibility of the data submitter. Unfortunately, we found more or less appropriate information on physicochemical properties and concluded that more quality or adequacy of any data submitted will be needed.
Interlaboratory tests play a decisive role in assessing the reliability of test results. Interlaboratory tests on different test methods have been performed by Bundesanstalt für Materialforschung und –prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB) in collaboration with the QuoData GmbH during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory tests. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method.
In view of the interlaboratory test results the following conclusions can be drawn:
• To avoid any discrepancy on classification and labelling of chemicals it should become state of the art to use validated test methods and the results accompanied by the measurement uncertainty.
• A need for improvement is demonstrated for all examined test methods. Thus, interlaboratory tests shall initially aim at the development, improvement and validation of the test methods and not on proficiency tests.
• The laboratory management and the practical execution of the tests need to be improved in many laboratories.
• The term "experience of the examiner" must be seen critically: A "long experience with many tests" is not necessarily a guarantee for correct results.
Prävention beginnt im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. Bei der Prüfung der gefährlichen Eigenschaften von Chemikalien sind Referenzmaterialen auf Grund der Instabilität in der Regel nicht verfügbar. Für Prüflaboratorien sind RV daher eine Alternative bei der Qualitätssicherung. RV sind jedoch aufwendig und können nur in relativ großen Zeitabständen durchgeführt werden. Es sind deshalb Verfahren zur Verifizierung z. B. der in den Laboratorien verwendeten Prüfapparaturen zu entwickeln. Die Entwicklung von Verifizierungsverfahren wird am Bespiel der Prüfmethode UN Test N.5 demonstriert.
Die Ursachen für Chemikalienunfälle können vielfältig sein. Prävention beginnt bereits im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse.