We are interested in accidental fire impingement of HazMat pressure vessels. Want to develop improved models for predicting time to failure or empty (if PRV present). We are still trying to properly predict pressurization and time to first PRV activation due to liquid temperature stratification for a range of fire scenarios (Full and partial engulfing pool fire, jet fires, with roll over, with TP defects, etc.)
An overview of test standards and regulations relevant to the fire testing of pressure vessels
(2021)
Fire exposure of storage and transportation vessels of hazardous materials (including pressure liquefied gases) can result in BLEVEs and other high-consequence incidents with large societal and economic impacts. To reduce risk most countries have numerous regulations, codes of practice and guidance notes covering the design, operation and maintenance of vessels and thermal protection systems. Yet despite such regulations there remains no internationally accepted fire test procedure for pressure vessel and accompanying thermal protection systems that is capable of meeting a range of regulatory requirements. This paper considers some of the regulations in place in the western world and considers the origin of these based on large and medium-scale testing conducted to date. It examines conditions found in these tests to propose a set of recommendations on which to base a standard method of test. These recommendations are proposed as being representative of a credible large pool fire scenario that may occur.
A novel deign of test equipment has been commissioned to investigate thermal stratification and boiling during fire exposure of pressure vessels. Extensive temperature measurements and video of the internal conditions during fire exposure are possible, and the equipment has been designed for future compatibility with laser-based velocity measurement techniques. It is expected to generate data large quantities of data that will be of use in validation of two- and three-dimensional CFD models for the prediction of pressure vessel behaviour in fire. Future work will seek to characterize the boundary layer conditions in detail for a range of test fluids, fill levels and fire-induced thermal boundary conditions.
Initial tests undertaken during commissioning may indicate that fire exposure of the vessel wall just above the liquid level can have a notable influence on the pressurization rate, by increasing the degree of superheat. Further experimental and modelling work is required to confirm and quantify this effect, or to rebut this conclusion.
Pressurisation of full-containment pressure vessels in fire is known to be driven by thermal stratification. The predominant mode of heat transfer to the contents (convection from the shell to the liquid phase) results in formation of „hot“ boundary layers. Sub-cooled boiling may also be present. The warm layer rises to the surface through buoyancy and bubble flow, increasing the surface of the liquid above that of the bulk temperature, and hence driving a pressure rise.
For reliable prediction of the complex effects governing vessel pressurization a three-dimensional numerical model is required. Work is being undertaken on such a model by other institutions in cooperation with this project.
In North America certain hazardous materials are transported in rail tank cars that must be able to survive an engulfing liquid hydrocarbon pool fire for 100 minutes without rupture. To meet this requirement these tanks are normally equipped with pressure relief valves (PRV) and some form of thermal insulation or thermal protection (TP).
These tanks sometimes have non-accident releases (NAR) due to unwanted activation of, or leakage from the pressure relief valves (PRV). These NARs are a nuisance for Industry and for this reason, the industry now wants to remove the PRVs from certain tanks. This is known as total containment and is common practice in Europe. However, Europe does not have a 100 minute fire survival requirement. This paper is about a series of fire tests of 1/3 rd linear scale US DOT 111 Tanks cars. The 2.4 m3 vessels were subjected to fully engulfing fires generated by liquid propane fueled burners.