A process spectroscopic approach for the monitoring of microplastics in environmental samples
(2018)
The potential of Raman and NIR process-spectroscopic as a rapid approach for the estimation of microplastics (MP) in soil matrix were tested. For this purpose, artificial MP/soil mixture samples consisting of standard soils or sand with defined ratios of MP (0,5 – 10 mass% polymer) from polyethylene (PE), polypropylene (PP), polystyrene (PS) and polyethylene terephthalate (PET) were prepared. MP particles with diameters < 2 mm and < 125 µm were obtained from industrial polymer pellets after cryo-milling. Spectra of these mixtures were collected by (i) a process FT-NIR spectrometer equipped with a reflection probe, (ii) by a cw-process Raman spectrometer and (iii) by a time-gated Raman spectrometer using fiber-optic probes. The evaluation of process-spectra was performed by chemometric methods. Whereas MP could be detected by Raman spectroscopy in coastal sand at 0.5 mass%, in standard soil detection of MP was limited to 10 – 5 mass% with the large fraction, but samples containing particles of the 125µm mass-fraction yielded no positive result at all. One reason for the lacking sensitivity could be fluorescence by soil organic matter and thus, in a next test time-gated Raman spectroscopy was applied. However, although being indeed more sensitive to the small particles this method failed at MP < 5 mass% indicating that fluorescence was not the major problem. Finally, FT-NIR was tested. Depending on the polymer, MP contents of 0,5 or 1 mass%, respectively, could be detected in standard soils and polymers identified. Furthermore, this approach could be used for the investigation of mixtures of up to four polymers and in real-world samples from bio-waste fermenter residues.
Raman spectroscopy for online monitoring of a homogeneous hydroformylation process in microemulsion
(2021)
An important industrial reaction is hydro¬formylation for the production of aldehydes from alkenes and syngas on the basis of homogeneous catalysis. The main cost factors of the processes currently used are product selectivity and the loss of the catalysts used. Therefore, various concepts for the hydroformylation of long-chain olefins have been developed, including hydroformylation in microemulsions, which is being investigated on a mini-plant scale at the Technical University of Berlin [1]. In this study, online Raman spectroscopy of the reaction of 1-dodecene to 1-tri¬decanal in a microemulsion was performed [2]. First, an experimental design was used to obtain a good representation of the operating range in the mini plant with respect to the concentrations of five reactants in a laboratory setup [3]. Based on the Raman spectra, Partial Least Squares (PLS) models for the prediction of 1-dodecene and 1-tride-decanal were calibrated and with these the reactions were predicted on a laboratory scale. In the next step, the PLS models were applied to online spectra from a mini-plant. This resulted in promising estimates of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions. The predictive power of PLS models in this particular case was limited by unexpected by-product formation which, however, can easily be compensated by an extended calibration. Hence, Raman spectroscopy is a promising technique for process analysis in microemulsions.
In the present talk the basics of the Raman spectroscopy and particularly of Raman microscopy are explained. Advantages and disadvantages of the method are highlighted through selected case studies. In the second part of the lecture examples of correlative imaging with electron, X-ray, ion and optical microscopies from micro- to the nanoscale are highlighted.