Filtern
Dokumenttyp
- Vortrag (16) (entfernen)
Sprache
- Englisch (16)
Referierte Publikation
- nein (16)
Schlagworte
- Mass spectrometry (16) (entfernen)
Organisationseinheit der BAM
To understand the metabolic fate of food relevant mycotoxins in vitro systems were mainly used as the method of choice, so far. Yet, in recent years coupling of electrochemistry mass spectrometry (EC-MS) gained increasing importance as promising technique for fast simulation of metabolic processes and was successfully applied in particular for drug metabolism [1].
The aim of our work was to investigate the potential of EC-MS to predict phase I metabolites of priority mycotoxins and to compare the results with in vitro experiments. Hence, the EU-regulated Fusarium mycotoxins zearalenone (ZEN) and patulin as well as dihydroergocristine (DHEC) as model compound of ergot alkaloids were electrochemically oxidized and analyzed by EC MS for the first time.
Electrochemical conditions were set-up individually for each of the three mycotoxins. By using a coulometric flow through cell with a diamond working electrode oxidation of the chosen mycotoxins was observed after applying potentials between 1.7 and 2.0 V vs. Pd/H2. The electrochemically generated reaction products were analyzed online by mass-spectrometric detection.
All of the three chosen mycotoxins were electrochemically converted to mono- and/or dihydroxylated products confirming the results of ZEN related metabolism studies [2, 3] and in case of DHEC own results from in vitro assays. Due to a lack of metabolism studies concerning the oxidative fate of patulin, interpretation of EC-MS data and performing microsomal studies is of particular relevance.
Beside the identified products from electrochemical oxidation of ZEN, patulin and DHEC there is still a number of yet unknown compounds. Additional structural characterization of detected compounds by NMR and X-ray analysis will be facilitated by their large-scale production using preparative EC cells.
Real time monitoring of chemical reactions has become a key step in industrial processes due to constantly increasing demands on product performance and environmental compatibility. In contrast to spectroscopic methods that usually require sample pretreatment, mass spectrometry (MS) has been proven as a robust method for multicomponent analysis. As an especially demanding reaction process, we here report successfully on the entirely contactless conduction and interrogation of a chemical reaction inside an acoustically levitated microliter droplet of reaction mixture. The approach represents a proof of concept study for fast reaction optimization approaches with minimal resource consumption. The sampling is done by repeated laser desorption of small fractions of the droplets volume spread over the timescale of the reaction process.
Copolymer structure elucidation by multidimensional techniques with focus on UPLC x ESI-TOF-MS
(2017)
Structure elucidation of complex synthetic copolymers still represents a challenge. An one-dimensional separation technique cannot give the answer to the question: What are the molar mass distribution (MMD), the functionality distribution (FTD), the chemical composition distribution (CCD), the monomer sequence distribution (MSD), the topology differences within a single broad distributed polymer sample?
Since the first LC/ ESI-MS experiment of the Nobel prize winner John B. Fenn in 1984, the coupling of liquid chromatographic to mass spectrometric techniques gained a continuous rapid development.
Often the deficiencies of stand-alone methods can be bridged. LC, blind to structural information needs mass spectrometry as one of the most powerful detectors able to give detailed information on e.g. the repeat units, functionalization or copolymer composition of the chromatographic separated constituents. A separation prior to MS reduces radical the dispersity which is one of the reasons for failing of MS. Also problems with different ionization probabilities in complex mixtures can partly be overcame.
Different LC separation techniques as size exclusion chromatography (SEC), liquid adsorption chromatography (LAC), liquid chromatography at critical conditions (LCCC) and gradient elution liquid chromatography (GELC) combined with Matrix assisted Laser Desorption Ionization (MALDI) respectively Electrospray Ionization (ESI) Time of Flight (TOF) mass spectrometry are able to give information which otherwise are completely inaccessible. In some cases CID tandem mass spectrometry is applied. Fragmentation of suitable precursor ions resulted in typical fragment ion patterns. This technique enables an additional information on e.g. sequences, structural defects and topology of complex polymer mixtures.
Herein a new approach is demonstrated to provide evidence of different functionalities and short block sequences in statistical EO-PO copolymers. Furthermore silsesquioxane mixtures and Polyglycerols are investigated concerning occurring topology effects.
A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities.
The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions.
For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highly-excited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization.
These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event.
A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities.
The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions. For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highlyexcited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization.
These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event.
Heavy alcohol induces several chronic diseases, including cirrhosis. Consequently, cirrhotic patients need liver transplantation. However, alcoholic patients are not suitable for this. How can be physicians sure of non-alcohol consumption of a potential organ receptor? Monitoring of biomarkers by mass spectrometric techniques is today the most suitable option. This subject was discussed at the Graduate School of Analytical Science Adlershof (SALSA) in Berlin, as a part of a lecture series in analytical science.
High-resolution mass spectrometry, either combined with gas or liquid chromatography (GC/LC-HR-MS), is currently the most powerful analytical option for broad nontargeted small molecule analysis. To transform HR-MS raw data from metabolomics or environmental studies into chemically meaningful data, several computational steps are needed, including peak detection, deconvolution of these peaks into compounds and putative identification of compounds using databases. Each of these steps can cause problems and still requires methodological advancements. Computational compound annotation as one of the steps, however, has proven particularly challenging, mainly due to the chemical diversity of organic analytes. In addition, different annotation approaches are needed for the different platforms used in HR-MS screening. We recently introduced InterpretMSSpectrum as an annotation workflow for GC-HR-MS using atmospheric pressure chemical ionization (APCI). InterpretMSSpectrum locates molecular ion, fragment and adduct peaks, calculates their most likely sum formula combination and graphically summarizes results as an annotated mass spectrum. As a complementary approach for LC-HR-MS, we presented findMAIN, which scores MS1 spectra based on explained intensity, mass accuracy and isotope charge agreement of adducts and related electrospray ionization (ESI) products to determine the neutral mass of unknown compounds. Both approaches were validated against large spectral libraries containing more than 600 compounds, for which correct annotation was achieved in over 80% of the cases. Based on the experiences from this validation, we here compare soft-ionization GC/LC-HR-MS regarding “annotatability” of unknown compounds from a computational perspective. As a main advantage for GC-HR-MS, the relatively uniform ionization behavior of commonly used trimethylsilyl (TMS) derivatives observed under APCI allowed differentiation of molecular ion peaks from in-source fragments based on relatively compact set of rules. By contrast, neutral mass inference in ESI required a more complex evaluation scheme, due to the higher diversity of ionization products observable in ESI. We demonstrate such differences by practical examples of both software packages applied to metabolomics studies and discuss the challenges connected to transferring the approaches to environmental screening.
Boehmite nanoparticles has been successfully functionalized with APTES. After APTES functionalization further modification with tailored molecules e.g. via carboxylic acids is possible. The tailored surface functionalization is strongly enhanced by improved coupling protocols. Arbitrary variation of the functionalization degree is possible. Thereby the temperature stable APTES functionalization enables a wide range of functional groups.
By TGA-MS analysis strong evidence for the bonding situation of the APTES on the boehmite surface has been found. Additionally first experiments has been performed to predict the polymer-particle compatibility enhancement via reverse wetting angle measurements with AFM.
Mass spectrometric Methods MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
Optical spectrometric methods are proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry (LAMIS). First, stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated heteronuclear diatomic molecules (MH or MX) in graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. Finally, the application of molecular spectrometry via emission by LAMIS is compared and discussed.
Since its introduction mass spectrometric techniques like Matrix-assisted Laser Desorption/ionization (MALDI) and Electrospray Ionization (ESI) have become indispensable for synthetic polymer analyses. Ideally, various polymer properties (monomer structure, masses, mass distribution, end groups) can be determined simultaneously. However, in real life these experiments are always affected by important structural parameters and instrumental limitations.
A short introduction focussing on latest findings with respect to ionisation principles and mechanisms will be given. Recent results from our group will be presented and efforts to avoid common drawbacks of polymer mass spectrometry will be discussed. In this regard, MALDI - Imaging mass spectrometry and the 2D hyphenation of MS with different chromatographic separation techniques were especially useful, since they can provide additional information and reduce the complexity of polymer analyses.