In the last two decades automated ultrasonic inspection devices took over a lot of applications that prior have been carried out using manual inspection with the evaluation of A-scans only. In parallel phased array systems have been developed and brought to the market which offer detailed and fast control over the sound field. When applying automated inspection phased array systems for UT measurements imaging of the recorded data in combination with the probe positioning data is used for the evaluation of inspections. B-Scan, C-Scan and S-Scan images are typically used with this setup.
For more sophisticated applications with linear arrays echo tomography and syntethic aperture focusing technique (SAFT) are well known methods and often applied for high resolution image reconstruction. Since channel count of phased array systems is constantly rising, matrix arrays with up to 256 elements entered the market. Signal processing in the matrix domain became 3D. Since some years the Total Focusing Method (TFM) is an additional imaging tool for these type of application. It is based on the Full Matrix Capture (FMC) using the elements of phased array probes as separate transmitters and receivers.
In this contribution we discuss the common ground of SAFT and TFM as well as the differences between these imaging tools. The combined use of automated inspection, matrix arrays and signal processing for high resolution measurements is a challenging task where a very long parameter list has to be taken into account. Under which conditions which elements of the full matrix should be taken for the reconstruction for best results?
Based on examples taken from measured and simulated echo signals it will be shown how image resolution can be optimized in dependence of different parameters like the distance between transmitters and receivers and their directivity patterns, the depth of echo source and the specimen geometry.
Underground sealing structures are necessary to seal radioactive or toxic waste in underground repositories. Particularly developed MgO concrete is used in the mine in Teutschenthal and applied at a large-scale test with the aim to provide concrete with low permeabilities. The test structures (up to 10 m long) were created with the help of a shotcrete procedure. Besides destructive tests, non-destructive ultrasonic measurements are used for quality assurance to monitor potential anomalies such as cracks, concrete inhomogeneities, and delamination. We show results of ultrasonic measurements with a multi-transducer system used at the front site of the concrete structure. Images are obtained by synthetic aperture focusing techniques. Concreting sections are not systematically imaged so that a successful concreting is assumed as also indicated by observed low permeabilities. Several reflectors up to a depth of 1.2 m are identified and interpreted as potential damages in the concrete. Phase analysis of prominent reflectors reveal a negative impedance contrast thus indicating air filled voids, cracks or delamination. Boreholes through some of the identified reflectors are used to verify the results from ultrasonic measurements. Additionally, an experiment with incorporated defects is undertaken to analyse the reliability of the applied methods. Overall, the conducted tests show the great potential of ultrasonic measurements to detect critical anomalies. Despite challenges at small-scale structures (cm-order), large-scale anomalies can be identified. Implementing ultrasonic monitoring during and after the construction of concrete sealing structures is recommended as a tool for quality assurance.
Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring and inspection techniques within the project SealWasteSafe.
After successful laboratory analysis on the cm-scale, cylindrical and cuboid specimens on the m-scale are produced from classical salt concrete and a specifically developed alkali-activated material. A comprehensive multi-sensory monitoring scheme is applied to compare the setting process of both materials and to demonstrate the sensors’ resistance to highly alkaline environments. Besides temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than 8 months. Passive sensor systems based on radiofrequency identification technology (RFID) embedded in the concrete allow for wireless access to temperature and humidity measurements and are compared to conventional cabled systems. After hardening and removal of the outer casings of the specimens, further non-destructive evaluations using ultrasonic echo and thermographic measurements are conducted. Preliminary results clearly highlight differences between the tested materials, particularly showing lower acoustic emission activity for the newly developed alkali-activated material potentially indicating less phase changes or cracks.
Complementary, ultrasonic methods are improved to be used for quality assurance to detect obstacles, potential cracks and delamination at in-situ sealing structure scale. A unique large aperture ultrasonic system (LAUS) with depth penetration as large as 9 m has already successfully been applied at the test site in Morsleben, Germany, of the federal company for radioactive waste disposal (BGE). Modelling studies help to further optimize the measurement layout. Advanced imaging techniques applied to the modelled and measured data will further improve the obtained images of internal structures. Additionally, an ultrasonic borehole probe is developed and constructed using phased arrays to further enhance the detection of potential cracks. Modelling and preliminary results from laboratory specimens prove the feasibility and potential of the directional response even in heterogeneous material such as concrete. Final investigations under in-situ conditions at the test site of the sealing structure are planned.
Overall, the project SealWasteSafe improves the construction material, multi-sensory monitoring, and ultrasound for quality assurance to allow for the development of safe nuclear sealing structures. Although the techniques are tailored for sealing structures within salt as a host rock, they are transferrable to a wider field of applications and alternative disposal conditions.