Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (38) (entfernen)
Referierte Publikation
- nein (38) (entfernen)
Schlagworte
- Standardization (38) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (8)
- 4 Material und Umwelt (7)
- 4.1 Biologische Materialschädigung und Referenzorganismen (7)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 1.2 Biophotonik (4)
- 6.7 Materialsynthese und Design (3)
- 5 Werkstofftechnik (2)
- 5.2 Metallische Hochtemperaturwerkstoffe (2)
- S Qualitätsinfrastruktur (2)
Eingeladener Vortrag
- nein (38)
In 2011, the German Association of Engineers (VDI) started working on a set of guidelines towards increased resource efficiency. These guidelines represent a framework that defines resource efficiency and outlines considerations for the producing industry. A special guideline for SMEs is included as well as guidelines on methodologies for evaluating resource use indicators, such as the cumulative raw material demand of products and production systems. Resource efficiency, defined here as the ratio of specific quantifiable use to natural resource consumption, can be evaluated by defining a function which expresses the specific use and quantifies the resource requirements through a set of indicators (use of raw materials, energy, water, land and ecosystem services including sinks). The results from this also depend on the system boundary parameters and the allocation rules for by-products and waste treatment options. Optimising resource use is possible at all stages of a product’s or production system’s life cycle chain (raw material extraction, production and manufacturing, use and consumption, and the end-of-life stage). VDI guidelines are widely accepted across Germany’s industrial sector and therefore represent an important means of mainstreaming resource efficiency in this target area. As well as providing a methodological framework, the guidelines describe strategies and measures towards increasing resource efficiency, and they enable industrial producers and service providers to identify potential areas of improvement. The full article presents an overview of the methodology and contents of these guidelines and discusses their impact in achieving absolute reductions in the industrial use of natural resources.
The presentation will discuss the difference between EU and US standards for the determination of explosion (flammability) limits and limiting oxygen concentration. Small differences observed in measured values can be traced back to the different test apparatuses and criteria. The discrepancies can be much greater in the case of limiting oxygen concentration because of the high amount of inert gases and the corresponding low laminar burning velocities. The paper describes some examples and the influence of the chosen criteria on the results. The European and US standards use the criteria of flame propagation in open test vessels and of pressure rise in closed ones. The examples discussed show that flame propagation is still possible at very small pressure rise values, as observed much below the pressure rise criterion of usual standards. However, flame propagation in a process plant can cause an accident or explosion and must be avoided. Therefore, the flame propagation criterion is recommended to be used in chemical safety engineering. The European safety database CHEMSAFE contains expert-evaluated safety data for cases where the determination method and criteria are known. Flammability characteristics based on the pressure rise criterion may suffice in certain cases, e.g. for explosion protection in closed vessels without any connecting pipes.
The determination of organochlorine pesticides (OCP) and polychlorinated biphenyls is challenging because they are strongly physical and chemical bound to soil organic matter. There are various valid standards for the determination of these analytes in soil that differ especially in the extraction method and extraction time. In order to make profound assessments concerning the extraction efficiency seven extraction procedures namely pressurized liquid extraction (PLE), soxhlet and shaking with different extraction times 0.5 h, 1 h, 3 h, 6 h and 16 h were compared. For the study four soils of different total organic carbon (TOC) content were generated from uncontaminated reference soil and compost which were spiked to contaminant levels representative of the Bundes-Bodenschutz-Verordnung. Clean-up and measurement conditions using gas chromatography with mass spectrometry (GC-MS) were kept constant. Statistically analysis of the experimental values showed that recovery rates were not dependent on matrix TOC content. In consideration of measurement uncertainties of 10% - 20% for the determination of OCP and PCB in soil no differences in the efficiency between the tested extraction procedures could be observed.
The characterization of the optical properties of photoluminescent systems, that scatter, like dispersions of nanoparticles with sizes exceeding about 25 nm or solid nanophosphors is of increasing importance for many applications in the life and material sciences. Examples present nanoscale optical reporters and dye-doped microparticles for bioimaging, fluorescence assays or DNA sequencing as well as nanocrystalline emitters like semiconductor quantum dots and rods or lanthanide-based nanophosphors embedded into solid matrices for solid state lighting, display technologies, or barcoding/security applications. The assessment and comparison of material performance as well as the development of rational design strategies for improved systems require spectroscopic tools, which enable the determination of the signal-relevant optical properties like photoluminescence quantum yields and brightness values.
This encouraged us to built up an integrating sphere setup enabling absolute measurements of photoluminescence spectra and quantum yields of transparent and scattering photoluminescent dispersions and solid samples in different measurement geometries, i.e., direct and indirect illumination and the combination of both geometries and perform first measurements with selected emitters. Here, the design of this setup is presented and first recommendations concerning suitable measurement geometries are given.
The implementation of new 2-D materials based technologies in production processes requires the development of quality management tools. These have to be underpinned by appropriate measurements. Consequently there is a need for the development of the metrology for measurement methods, the development of certified reference materials (CRM) and finally standardization. This chain represents the ideal way to practically useful standards. The presentation will give an overview on the main players in the field and summarize the recent status of activities. At the highest level the metrology of chemical characterization of 2D materials is in the scope of the International Meter Convention, specifically the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM). Pre-standardization is an activity field of the Versailles Project on Advanced Materials and Standards (VAMAS). Standardization is mainly addressed by addressed ISO Technical Committees. A summary on available CRMs relevant to the characterization of nano materials has been prepared by BAM. Examples from the work of BAM’s Division 6.1 “Surface Analysis and Interfacial Chemistry” showcasing the characterization of chemically modified graphene surfaces are given and specific needs for the development of metrology are addressed.
In the discussion the audience is invited to define specific needs which will be streamlined to the respective bodies!
Elemental imaging of biological samples (bio-imaging) using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) provides spatially resolved information on element distribution (qualitative and quantitative) in thin sections of biological samples. By rastering with a laser across the sample, a two-dimensional image of the elemental distribution can be reconstructed that shows the relative intensities of the respective elements. However the method is hampered by a lack of internal standards and quantification concepts, which will be discussed in this lecture in more detail.
In liquid analysis the internal standard is used for drift correction and calibration and thus it is required that the standard should have similar physical and chemical properties similar to the analyte element during the pneumatic nebulization process, the transport, ionization and transmission into the ICP-MS. In laser ablation it should correct additionally for differences in the ablation process by laser instabilities or changes of sample properties to compensate variations or drift effects during the LA process.
Construction products are complex materials and contain a large number of different chemicals, which might be released to the environment during usage. Depending on the compound and on the matrix only a small portion is transferred to environment and therefore a risk assessment should be based on the available portion. Concerning the pathway to soil and groundwater by contact with rain or seepage water leaching tests were developed and standardized by CEN to determine the release potential of construction products. Chemical analysis in the eluates can be combined with eco-toxicological testing. In this presentation an overview about existing leaching methods is given using selected examples of our work. We especially draw the attention to research which is still needed to close the gap between the results of leaching experiments and the subsequent risk assessment of the products.
The eluates of 15 paints for outdoor use were used for a screening of organic compounds and the concentration of cations and anions were determined. Concerning the inorganic constituents only a small number of elements were present with concentrations higher than the limit of detection. Thus, leaching of potential hazardous chemicals is probably of higher concern. Several glycol ethers, polyalkylene glycols and some surfactants and coalescing agents have been identified. Among these only the latter are classified as hazardous to aquatic organisms. The identification of the organic compounds is a time consuming and labor-intensive step due to the high number of chemicals produced and used. Using eco-toxicity tests provides information on the environmental risk without the need for of chemical identification of all compounds. The screening of a set of construction products shows that only a part of eluates causes adverse effects in the test and that such screening can be used as a first step in the assessment of construction products. If this kind of testing is included in the evaluation concept an in depth chemical analysis is only needed for products showing adverse effects.
Determination of the eluate concentration after leaching enables to determine the potential release to the environment and to focus on the available fraction. However, limit values or other concepts to use this information in risk assessment are still missing.
With more than 180.000 engineers and scientists VDI Association of German Engineers and VDE Association for Electrical, Electronic & Information Technologies are belonging to the major technical and scientific associations in Europe. Both organizations promote the advancement of technology and among other things by developing recognized technical regulations as national and international standards. Since 2011 Technical Committee 2.15 Optical Measuring Methods for Structure Analysis and Monitoring as a common committee of both organizations is working among other things on the development of standards for optical measuring and testing methods. The committee consists of 27 members representing industrial users, system manufacturers, research institutes and universities. Currently the committee is drafting the new standard VDI/VDE 2626 Part 1 - Optical measuring procedures – Image correlation methods – Basics and equipment, which will be introduced in this presentation.
Draft VDI/VDE 2626 Part 1 describes practical acceptance and reverification procedures for the evaluation of the accuracy of optical measuring systems based on digital image correlation (DIC) methods. The document applies to DIC measurement systems used a) for full-field determination of two- or three-dimensional displacement of surfaces, and b) for
full-field determination of the elongation or strain of surfaces. The standard describes quality parameters as well as methods and reference objects for their determination. The quality parameters serve to specify DIC systems, and to compare different systems. They are equally suitable a) for acceptance tests as well as b) for reverification of DIC systems within the framework of a quality management system.
The acceptance test is used to determine whether the DIC system complies with the quality parameter limits specified by the manufacturer, or with contractually agreed limits by the manufacturer and user, respectively. For this test the quality parameters zero-displacement error, zero-strain error, and displacement error are defined and used. Zero-displacement error and zero-strain error describe minimum measurement uncertainties of the DIC system a user has to reckon with. They are influenced by different uncertainty contributions. The quality parameter displacement error is used to check the ability of the DIC system to determine absolute displacements within the measurement volume and to confirm the traceability of this measurement to the SI system.
Reverification of DIC systems serves to ensure long-term compliance with specified limits for the quality parameters. By comparing the results of successive reverification measurements of the quality parameters used for the acceptance test, it is possible to analyze trends with respect to changes in DIC system characteristics.
The presentation goes into the characterization of TiO2 engineered nanoparticles within EU/FP7 SETNanoMetro Project and the nanomaterial classification according to the EC definition tested within EU/FP7 NanoDefine Project. Further, ISO/TC 229/JWG 2 activities related on ISO standards in development and inter-laboratory comparisons on measurement of nanoparticle size and shape distribution by SEM and TEM are discussed.