Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (36) (entfernen)
Sprache
- Englisch (34)
- Deutsch (1)
- Mehrsprachig (1)
Referierte Publikation
- nein (36) (entfernen)
Schlagworte
- Reference material (36) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (15)
- 1.2 Biophotonik (12)
- 6 Materialchemie (10)
- 6.6 Physik und chemische Analytik der Polymere (7)
- 6.1 Oberflächen- und Dünnschichtanalyse (5)
- 1.1 Anorganische Spurenanalytik (2)
- 4 Material und Umwelt (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 1.6 Anorganische Referenzmaterialien (1)
- 5 Werkstofftechnik (1)
The characterization of the optical properties of photoluminescent systems, that scatter, like dispersions of nanoparticles with sizes exceeding about 25 nm or solid nanophosphors is of increasing importance for many applications in the life and material sciences. Examples present nanoscale optical reporters and dye-doped microparticles for bioimaging, fluorescence assays or DNA sequencing as well as nanocrystalline emitters like semiconductor quantum dots and rods or lanthanide-based nanophosphors embedded into solid matrices for solid state lighting, display technologies, or barcoding/security applications. The assessment and comparison of material performance as well as the development of rational design strategies for improved systems require spectroscopic tools, which enable the determination of the signal-relevant optical properties like photoluminescence quantum yields and brightness values.
This encouraged us to built up an integrating sphere setup enabling absolute measurements of photoluminescence spectra and quantum yields of transparent and scattering photoluminescent dispersions and solid samples in different measurement geometries, i.e., direct and indirect illumination and the combination of both geometries and perform first measurements with selected emitters. Here, the design of this setup is presented and first recommendations concerning suitable measurement geometries are given.
Mandatory for the comparison of different emitter classes and the rational design of the next generation of molecular and nanoscale reporters are reliable and quantitative photoluminescence measurements. This is of special relevance for all fluorescence applications in the life and material sciences. In the following, proccedures for the determination of this spectroscopic key parameter are presented including material-specific effects related to certain emitters
Creating the Silver Standard: Development of a Silver Nanoparticle Reference Material using SAXS
(2017)
The utilization of silver nanoparticles in consumer related products has significantly increased over the last decade, especially due to their antimicrobial properties. Today they are used in a high variety of products, which ranges from food containers over children toys and textiles. Therefore, research on the toxicological potential of silver in a nanoscale form becomes increasingly important for a high amount of studies. Unfortunately the results of these studies are extremely diverse and do not lead to a consistent evaluation of the toxicity of silver nanoparticles. The central problem lies in the use of a wide range of silver nanoparticles, which show a broad size distribution. To overcome this problem we report on the synthesis of ultra-small silver nanoparticles and their quantitative characterization by small-angle X-ray scattering. The particles are highly stable and show no aggregation for more than six months. SAXS analysis via a Monte Carlo data evaluation procedure reveal a narrow size distribution of the silver cores with a mean volume weighted radius of 3.0 nm and a distribution width of 0.6 nm. Dynamic light scattering provides a hydrodynamic radius of 10.0 nm and a PDI of 0.09. The particles are stabilized with poly(acrylic acid) (PAA) forming a shell with a thickness of 7.0 nm. It is foreseen to use these thoroughly characterized particles as reference material to compare the catalytic and biological properties of functionalized silver nanoparticles. As a first step the particles are used in the first world-wide inter-laboratory comparison of SAXS. This study reveals that SAXS shows highly reproducible results for particles in the sub-20 nm region independently on the type of instrument used. Furthermore, the stabilizing ligand PAA can be easily exchanged by biomolecules to modify the surface functionality. Replacements of PAA with glutathione (GSH) and bovine serum albumin (BSA) have been performed as examples. With this flexible system first applications regarding biological application in an artificial digestion procedure have been performed. Thereby the changes in size distribution and aggregation state were monitored by SAXS.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.
Since some volatile organic compounds (VOC) are
dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks.
Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers
(2017)
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results.
Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found.
Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT.
Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions.
The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber.
Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results.
Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks.