Filtern
Dokumenttyp
- Vortrag (13) (entfernen)
Referierte Publikation
- nein (13) (entfernen)
Schlagworte
- Nanopartikel (13) (entfernen)
Organisationseinheit der BAM
- 4 Material und Umwelt (6)
- 4.2 Material-Mikrobiom Wechselwirkungen (6)
- 6 Materialchemie (3)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.1 Anorganische Spurenanalytik (1)
- 1.2 Biophotonik (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
Eingeladener Vortrag
- nein (13)
Aerosol emissions from brake pads are evolving into the focus of industrie and regulation. Many institutes are extending their dynamometer test stands with aerosol measurement equipement. While this is in general a good developement, the details of aerosol measurement and the special problems in the case of brake pad emissions need some special attention. The instrumentation can not be used out of the box and the important parameters will be highlighted in this presentation.
Der Vortrag stellt ein Messverfahren zur Bestimmung der Partikelgrößenverteilung an Suspensionen vor, behandelt die Anforderungen der zugrundeliegenden ISO 13318 und gibt praktische Hinweise zur Durchführung und Auswertung. Der Messbereich umfasst Partikel mit Durchmessern von wenigen nm bis etwa 5 µm; die Partikelkonzentration muss kleiner 0,2 Ma.-% sein. Enthalten sind ergänzend Vergleichsmessungen mit anderen volumenbasierten Verfahren.
Die Präsentation gibt einen Überblick über die verschiedenen Aktivitäten der BAM im Bereich der Nanotechnologie mit den Schwerpunkten Nanopartikel und Nanosicherheit. Es wird sowohl die Transportsicherheit, als auch die Sicherheit von Batterien mit Nanopartikeln angesprochen. Verschiedene BAM-Projekte zum Thema Nano werden vorgestellt, beginnend mit relevanten REFOPlanprojekten über die Erstellung der OECD nanoTG110 bis hin zu EU-Projekten zur Standardisierung von Messungen an Nanomaterialien, hier insbesondere AEROMET, NanoDefine, NanoValid und EC4SafeNano.
Projekt Nano-TG110
(2017)
Die OECD-TG110 mit dem Titel "Particle Size Distribution Fibre Length and Diameter Distribution" wurde 1981 erstellt und seither nicht überarbeitet. Nanomaterialien, wie Nanopartikel oder Nanofasern werden nicht adressiert, genausowenig wie moderne Messverfahren. Das hier vorgestellte Projekt hat zur Aufgabe, die Größenmessung von Nanopartikeln und Nanofasern in einer neuen Technical Guideline der OECD zu standardisieren. Es wird die Projekthistorie dargestellt, die Anforderungen, der aktuelle Projekt-Bearbeitungsstand wird beleuchtet und die weiteren Arbeiten werden kurz skizziert.
The particle size distribution is considered the most relevant information for nanoscale property identification and material characterization. The current OECD test guideline on particle size and size distribution (TG 110) is not applicable to ‘nano-sized’ objects. In this project we thus develop a new OECD test guideline for the measurement of the size and size distribution of particles and fibers with at least one dimension in the range of 1 - 1000 nm. A fiber is defined as an object having an aspect ratio of length/diameter l/d >3. The width and length of each fiber should be measured concurrently.
In order to measure the particle size distributions, many techniques are available. 9 methods for particles and 2 methods for fibres have been tested in a prevalidation study and appropriate methods will be compared in an interlaboratory round robin test starting in February 2019.
Atherosklerotische Läsionen können durch Magnetresonanztomographie (MRT) unter Verwendung von sehr kleinen Eisenoxidnanopartikeln (VSOP) sichtbar gemacht werden. VSOP akkumulieren in atherosklerotischen Plaques und dienen somit als Atherosklerosesonde.
Das Ziel dieses Projektes war die Abbildung der Verteilung von Europium-dotierten VSOP (Eu-VSOP) durch Laserablation ICP-MS in histologischen Dünnschnitten der Aortenwurzelregion des ApoE-Knockout-Mausmodells, das reich an atherosklerotischen Plaques ist. Darüber hinaus wurde untersucht, ob die VSOP-Akkumulation in den Plaques mit anderen Biomarkern der Entzündung wie Makrophagen und verändertem Endothel korreliert. Somit wäre eine Beurteilung, ob es sich hierbei um instabile bzw. vulnerable Plaque-Regionen handelt möglich. Zu diesem Zweck wurden Antikörper mit verschiedenen Lanthaniden markiert und mit der Eu-VSOP-Verteilung unter Verwendung von LA-ICP-MS in einem Multiplex-Messmodus korreliert.
Eine mögliche Korrelation von reaktiven Stickstoffspezies (RNS) mit endogenem Eisen oder Eu-VSOP kann ebenfalls durch LA-ICP-MS nachgewiesen werden. Zu diesem Zweck wurden RNS-spezifische Antikörper auch mit Lanthaniden markiert.