Environmentally-assisted material degradation involves mass transport and mechanical processes interacting in the material. A well-known example is hydrogen-induced stress-corrosion cracking. One major challenge within this scope is the quantification of the coupling mechanisms in question. The computational modeling of environmentally-assisted cracks is the key objective of this investigation and realised within the theory of gradient-extended dissipative continua with lengthscales. The modeling of sharp crack discontinuities is replaced by a diffusive crack model based on the introduction of a crack phase-field to maintain the evolution of complex crack topologies. Within a thermodynamical framework allowing for mechanical and mass transport processes the crack phasefield is capable to model crack initiation and propagation by the finite element method. As complex crack situations such as crack initiation, curvilinear crack patterns and crack branching are usually hard to realise with sharp crack models, they can be assessed without the requirement of a predefined crack path within this method. The numerical modeling of a showcase demonstrates a crack initiation as well as a crack propagation situation with respect to the determination of stress-intensity factors; a crack deviation situation with a curvilinear crack path is modeled by the introduction of a geometrical perturbation and a locally enhanced species concentration.
Four-point bending tests were carried out to analyze the acoustic characteristics of damage development in pipe segments made of steel, grade S355J2H, being 2.5 m long with an outer diameter of 168 mm and 16 mm wall thickness. To induce stable crack growth, the pipe segments were pre-damaged by a 90°circumferential notch in the middle of the pipe length. While the pipe was quasi-statically loaded, microscopic damage and plastic deformation accumulated to form a macroscopic crack that grew through the pipe wall until leakage. For acoustic emission (AE) monitoring, four broadband sensors of type VS 900 M were mounted close to the notch. Continuous AE signal detection was performed by the non-threshold method. Advantages and disadvantages of the non-threshold AE monitoring compared to a commonly employed method analyzing only signals exceeding a predefined threshold are discussed. The results of AE analysis are compared to additional information on the crack growth detected by the direct current potential drop (DCPD) technique. These studies were carried out in the course of the interdisciplinary research project AGIFAMOR, Ageing infrastructures - distributed acoustic monitoring of pipes at BAM.