The vulnerability of low quality concrete to changing weather conditions is well known. The constant exposure to temperature changes, biological activity, and humidity ends up in damage to buildings and structures which contain this material. It is therefore necessary to take preventive measures to control the extent of the damage done by weathering and possible penetration of adverse chemicals into structures which need public safety.
The Federal Institute for Materials Research and Testing (BAM), in cooperation with the small enterprise LinTech GmbH, is working on a project to monitor humidity changes in concrete by analyzing the changes in signal strength (RSSI) from Bluetooth Low Energy sensors. In this paper, we show results which demonstrate the influence of changing water content in concrete on the received RSSI. We observed that as water content in concrete decreases, the received RSSI improves. However, the damping effect is not linearly proportional to water content, rather exponentially proportional. This suggests that changes in the received signal strength are more easily observed when water content in concrete is higher. Finally, we reconstructed a RSSI distribution map using computed tomography
Quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing, with particular focus on additively manufactured materials. I will also show how X-ray refraction computed tomography (CT) and Neutron diffraction can be highly complementary to classic absorption CT, being sensitive to internal interfaces and residual stress analysis, respectively.
The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread equally holds for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated.
I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. Examples of micro-structured inhomogeneous materials will be given, such as Composites, Ceramics, Concrete, and Additively manufactured parts. I will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces.
Additionally, I will present a new technique in our portfolio, Neutron Diffraction, which is extremely well suited to the study of internal stresses, both residual and under external load.
The layer-by-layer Additive Manufacturing (AM) by means of Selective Laser Melting (SLM) offers many prospects regarding the design of a part used in aeroplane components and gas turbines. However, structural deviations from the nominal morphology are unavoidable. The cooling of the finished part leads to shrinkage and a high surface roughness is induced by attached powder particles affecting the part volume too.
The integrity and load-bearing capacity of a SLM produced lattice structure has been investigated by means of in-situ X-ray computed tomography during compression. The lattice structure was compressed by 10 % in height with an applied maximum force of 5 kN. Additionally, a single strut has been investigated ex-situ as a component of the lattice structure. With the higher resolution achieved on the single strut, the pore distribution (size and location) as well as the surface roughness were assessed. The particle and pore size distribution of the raw powder have been investigated, too. One of the main results coming from the in-situ analysis was that the nodes were identified as the weakest points in the lattice structure.
This PhD project is part of the Marie Skłodowska-Curie International Training Network MUMMERING. The overarching goal of MUMMERING is the creation of a research tool that exploits the wealth of 3D imaging modalities applied in materials engineering.
The focus of this work is advanced reconstruction algorithms. The primary objective is the development and implementation of the DIRECTT algorithm. Due to restrictions introduced by the sample or the imaging setup during a measurement, it is not always possible to acquire data that fulfil the Nyquist sampling criterion. The DIRECTT algorithm is intended to produce reconstructions of superior quality for such cases of limited data sets, compared to those of other available algorithms, such as algebraic iterative ones. Although DIRECTT has been developed primarily for the reconstruction of volumes from data acquired by an X-ray Computed Tomography scanner, it can also be applied to the different modalities, such as laminography.
The talk describes the reconstruction principle of DIRECTT. Furthermore, reconstructions of measured data are presented and compared to reconstructions produced by other established algorithms.
X-Ray Computed Tomography (CT) is applied in industry for flaw detection, flaw evaluation and dimensional measurement. This requires the correct CT system settings for sufficient visibility and detectability of flaws and structure elements. The visibility of indications for human observers on a monitor depends on the square root of the reconstructed flaw area (here pores with diameter < ½ inch) in the cross sectional 2D images, the Contrast to Noise Ratio (CNR) and the Modulation Transfer Function (MTF). This applies also to 2D-projections, meaning also to “normal” digital radiographs. The ASTM guide E 1441 describes three essential functions for prediction of the visibility of small circular indications in slice images of a 3D reconstruction or a 2D reconstruction. This is the Contrast Discrimination Function (CDF), the MTF (see also the revision of ASTM E 1695), and the Contrast Detail Dose (CDD) function. The prediction of the visibility of circular indications in reconstructed slice images can be determined from the Contrast Detail Dose function, which is the combination of CDF and MTF and a physiological factor c. The measurement procedures and formulas for the prediction of the detail visibility by CDD will be corrected, tested and verified by modelling and in a Round Robin Test with modern commercial 3D CT systems of different manufacturers. Conclusions will be reported and recommendations will be given for the correct psychological factor c and the consideration of the influence of artefacts, as e.g. cupping and scatter.
The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread equally holds for industrial and academic research and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated.
I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. Examples of micro-structured inhomogeneous materials will be given, such as Composites, Ceramics, Concrete, and Additively manufactured parts. I will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces.
Additionally, I will show how Neutron Diffraction, which is extremely well suited to the study of internal stresses, both residual and under external load, can well be coupled to the microstructural framework gained by CT, allowing understanding the microstructure-property relationships in materials.
The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread equally holds for industrial and academic research and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated.
I will show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. Examples of micro-structured inhomogeneous materials will be given, such as Composites, Ceramics, Concrete, and Additively manufactured parts. I will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces.
Additionally, I will show how Neutron Diffraction, which is extremely well suited to the study of internal stresses, both residual and under external load, can well be coupled to the microstructural framework gained by CT, allowing understanding the microstructure-property relationships in materials.
Finally, I will show that BAM is very active in standardization and certification, including production of Reference Materials and Methods.
Avoid living dangerously: non-destructive characterization of AM parts from powder to end-of-life
(2019)
The freeform and the revolutionary design possibilities offered by additive manufacturing have skyrocketed the amount of optimization studies in the realm of engineering, and metallic additive manufactured parts are becoming a reality in industry.
Not surprisingly, this has not been paralleled by a similar enthusiastic wave in the realm of materials science, and still very little is known about AM materials properties. This has the consequence that, typically, conventional materials properties are still used in design and even in simulations.
lt is necessary to dig a lot deeper than at present, in order to understand these new materials classes, and in particular their microstructure and their intemal stresses, largely different from their cast or wrought companions.