The transport of peracetic acid (PAA) in intermediate bulk containers (IBC) and tanks is only possible if they have suitable pressure relief devices. To determine the dimension of the pressure relief devices the 10-l-model tank of annex 5 of the UN Manual of Tests and Criteria is used.
During the investigation of a PAA this model tank fragmented. To prevent such violent events in the future, the model tank should be provided with additional pressure relief devices.