The presentation reflects the questions that have been raised by member states and NGOs.
As background information details on the question how to choose a suitable salvage pressure receptacle (SPR) are provided. This leads to the need for deleting the volume limitation for SPRs and to the discussions in 2014 and 2016 on this issue.
As an adequate substitution for deleting the volume limit for SPRs it is proposed to limit the pressure receptacles to be stored in by a maximum pressure-volume-value of 1.5 Mio bar-litres.
After some explanations to standardisation projects currently also tackling this pV-limit, some risk-based safety criteria for a limitation are mentioned with the focus of the consequence level and the general avoidance of catastrophic worst case scenarios.
First the acceptance rates resulting from the analysis of different minimum burst ratios and standards are displayed and explained. Especially the problems resulting from a further reduction if the minimum burst ratio are shown.
For a better understanding of these results the process of analysing the acceptance rate is explained in detail. This contains the alleged contradiction between safety of samples due to its scatter while the rejected sample provides a higher mean strength.
Then the importance of batch testing is explained and leads to the recommendation to have a strong interaction between provided mean strength and requested maximum of production scatter.
Im DGMK-Projekt 780 wurde eine forcierte Prüfmethode entwickelt zur Bestimmung der Beständigkeit von metallenen Werkstoffen gegenüber Brennstoffen aus Mitteldestillaten und Gemischen aus Mitteldestillat und paraffinischen Kohlenwasserstoffen, die jeweils Fettsäuremethylester (FAME) als biogene Komponente enthalten. Bei der Prüfmethode werden Proben des Werkstoffes in einem speziellen Prüfmedien ausgelagert. Die Zusammensetzung von zwei Prüfmedien wurde im Vorhaben erarbeitet. Die Prüfmedien decken für den FAME-Anteil einen Bereich von bis zu 20 % (V/V) ab. Die Auslagerung kann bei geringem Aufwand unter Atmosphärendruck durchgeführt werden.
Die Eignung einer Auswahl von metallenen Werkstoffen und Polymerwerkstoffen, die für Versorgungsanlagen für Mitteldestillat relevant sind, wurde durch Auslagerung in folgenden nicht gealterten Brennstoffen bestimmt: Heizöl EL schwefelarm (B0), Heizöl EL schwefelarm mit 20 % (V/V) FAME (B20), FAME (B100) und hydriertes Pflanzenöl (HVO). Die Temperatur bei der Auslagerung betrug 50 °C für die metallenen Werkstoffe und 40 °C und 70 °C für die Polymerwerkstoffe. Die Ergebnisse der Beständigkeitsbewertung wurden in Beständigkeitslisten zusammengefasst. Die mit dem B20 erhaltenen Werkstoffbeständigkeiten gelten generell für Gemische aus Heizöl EL schwefelarm und FAME mit einem FAME-Gehalt bis zu 20 % (V/V). Sie sind auch auf Gemische aus Dieselkraftstoff und FAME mit einem FAME-Gehalt bis 20 %(V/V) übertragbar.
Die forcierte Prüfmethode kann insbesondere KMUs bei der Weiterentwicklung von bestehenden Produkten und der Entwicklung von neuen Produkten als ein kostengünstiger Schnelltest zur Überprüfung der Werkstoff- und Bauteilbeständigkeit gegenüber Mitteldestillaten mit hohem FAME-Anteil dienen. Sie kann für die Hersteller die Sicherheit erhöhen, dass Bauteile die Freigabeprüfungen der Bauaufsicht bestehen, wobei die Freigabe aber nur für Deutschland gültig ist.
Die Erkenntnisse des Forschungsvorhabens können in eine harmonisierte Europäischen Norm für alternative Brenn- und Kraftstoffe einfließen. Diese ist für die Bauteilhersteller die Voraussetzung für die Erschließung des europäischen Marktes.
Understanding the failure mechanisms that lead to leakage of rubber seals at low temperatures is important. Rubber properties are highly temperature dependent. Changes in behaviour at low temperatures can result from the rubber-glass transition and for some rubbers by partial crystallisation. Experimental results on the low temperature behaviour of different rubber seals were discussed to help understand seal failure processes.
The Dangerous Goods Regulations currently do not include limit leakage rates or sensitivity requirements for industrial leak testing procedures that are equivalent to the bubble test, which is the prescribed test method for design type testing of dangerous goods packagings. During series production of such packagings, various methods are used which often do not reach the sensitivity of the bubble test. Based on a suitable pragmatic approach, its sensitivity under industrial conditions can be considered 10-4 Pa m³/s (SLR).
For the selection of a suitable industrial leak testing method, however, factors other than the sensitivity are also important, for example flow direction, pressure level and automatability. The following methods are in principal suitable and equally effective as the bubble test: pressure rise test (vacuum chamber), ultrasonic bubble leak detection and gas detection methods (pressure technique by accumulation and vacuum chamber technique).
To ensure a uniform test level during design type testing and production line leak testing and therefore a comparable safety level as required by the Dangerous Goods Regulations, it is necessary to include a more precise specification in these regulations. On the one hand, this requires an information about the sensitivity of the bubble test, on the other hand, the inclusion of a list of suitable, equally effective industrial test methods with their specific boundary conditions
Packages for the transport of high-level radioactive material are designed to withstand severe accidents. Hypothetical severe accident conditions are defined in the IAEA Regulations for the Safe Transport of Radioactive Materials.
One of these accident conditions is the thermal test, mainly consisting of a 30 minute fully engulfing 800°C pool fire or an equally severe fire test. The heat fluxes into the package depend substantially on the fire characteristics and the Surface temperature of the package.
Fire tests can be performed at BAM on a propane gas fire test facility. In order to investigate the heat fluxes over a wide range of surface temperatures in this test facility a fire reference package was designed for multiple use. The package represented the outer geometry of a specific transport cask for radioactive waste. The fire reference package is a closed steel sheet cylinder with a wall thickness of 10 mm, a length of 1500 mm and a diameter of 1050 mm. The package was instrumented with thermocouples and filled with heat resistant insulation material.
Three open-air fire tests were performed in the BAM propane gas fire test facility. The flames exposure time period varied slightly for the fire tests. The wind direction as well as the wind Speed were measured and changed between and during the tests. Test stand parameters such as wind shield location and propane gas volume flow were chosen constant for the three tests. The locally measured fire reference package steel sheet temperatures were used for the calculation of heat fluxes as function of time and surface temperature. The measured temperatures allowed further calculations. In a first approach effective fire characteristics of the propane gas fire, including the flame temperature, the fire convection coefficient and a Radiation exchange coefficient mathematically describing the determined average heat flux over the surface temperature were calculated.
Vergleichende Fallversuche zur Bewertung von Fallfundamenten - Ausblick auf Untersuchungen der BAM
(2020)
Oft verfügen Produktionsstätten über bereits verbaute Fallfundamente, die nicht das geforderte Massenverhältnis von 1:50 aufweisen. Gemäß ADR ist jedoch auf dem Niveau der Musterprüfung zu prüfen. Es ist daher fraglich, ob die Prüfungen im Rahmen der Eigenüberwachung und die Baumusterprüfungen vergleichbare Ergebnisse liefern, wenn die Fallfundamente unterschiedlich beschaffen sind. Ziel der Untersuchungen ist daher die Entwicklung eines Untersuchungs- und Prüfkonzepts für bereits verbaute Fallfundamente für Gefahrgutverpackungen im Rahmen einer ingenieurwissenschaftlichen Promotionsarbeit.