Filtern
Dokumenttyp
- Vortrag (15) (entfernen)
Sprache
- Englisch (13)
- Deutsch (1)
- Mehrsprachig (1)
Referierte Publikation
- nein (15)
Schlagworte
- Sensor (15) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (7)
- 1.2 Biophotonik (4)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1.9 Chemische und optische Sensorik (2)
- 1.8 Umweltanalytik (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
Eingeladener Vortrag
- nein (15)
Two nanosensors for simultaneous optical measurements of temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nm-sized silica-coated polystyrene nanoparticles (PS-NPs) doped with the near infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3 CrBPh4)[1][2] and an inert reference fluorescence dye (Nile Red NR or 5,10,15,20-tetrakis-(pentafluorophenyl) porphyrin TFPP) and are covalently labeled with the pH-sensitive fluorophore fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal distinguishable emission spectra suitable for ratiometric intensity-based and time-resolved studies in the visible and near infrared spectral region. The core-shell nanostructure of these sensors reveals high colloidal stability in various aqueous media. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of the TOP nanosensors for optically detecting the three bioanalytically and biologically relevant analytes temperature, oxygen and pH simultaneously at the same position.
Sensor systems are widely used in hydrogen technologies. The lecture presents requirements and properties of sensor systems and shows application examples of these technologies for safety and process control for hydrogen technologies. The focus is on gas sensors as well as sensors for pressure, temperature and gas flow. These systems are applied, among other things, for monitoring and control of operating conditions, indication of hazardous conditions and triggering of alarms.
Ammoniakemissionen in die Umwelt erfolgen insbesondere durch die Landwirtschaft (93,6 %), aber auch durch Verbrennungsprozesse in der die Abfallwirtschaft (2,3 %) und den Straßenverkehr (1,8 %). Dieser Stoff ist selbst in geringen Konzentrationen nicht nur eine Geruchsbelästigung, sondern auch eine Substanz mit ökologischer und klimatischer Relevanz.
Die Bestimmung von Ammoniak in relevanten Konzentrationen von kleiner 25 μg m-3 erfolgt im Allgemeinen über NH4+ als Analyten, spektralfotometrisch oder mit der Ionenchromatographie nach Überführung in die flüssige Phase. Wegen der niedrigen Konzentrationen an Ammoniak in der Außenluft wird meist eine gesammelte Probe verwendet oder die Bestimmung erfolgt nach einer aktiven, anreichernden Probenahme.
Die eigenen Arbeiten sollen dazu beitragen, die Ammoniak-Bestimmung in der Außenluft präziser, sowie schneller und kostengünstiger zu machen.
Die BAM prüfte daher kommerzielle elektrochemische und Metalloxid-basierte Sensoren, die für diesen Konzentrationsbereich aber nur bedingt geeignet sind. Deshalb wurden alternativ eigene Entwicklungen zum Nachweis von Ammoniak im Spurenbereich aufgenommen, wobei der Analyt über die Änderung der Fluoreszenz eines BODIPY-Farbstoffs bei 550 nm mittels eines portablen Fluoreszenz-Sensors direkt aus der Gasphase gemessen wird.
Zur Kalibrierung von Ammoniak-Sensoren und -Messgeräten steht ein stationäres System basierend auf der Mischung von zertifizierten Prüfgasen aus Druckflaschen mit kalibrierten Massendurchfluss-regler (MFC) zur Verfügung. Darüber hinaus erfolgt eine chemische Analyse der verwendeten Gasgemische mittels eines Massenspektrometers.
Für die Kalibrierung und Prüfung von Sensoren und Messgeräten vor Ort wurde ein mobiles Prüfsystem entwickelt. Die Generierung von Ammoniak-haltigen Gasen im Spurenbereich von 0,5 nmol/mol bis 500 nmol/mol erfolgt durch das Permeationsverfahren nach ISO 6145-10.
Für die Realisierung der Rückführbarkeit der Ammoniakbestimmung werden von den Nationalen Metrologischen Instituten sowie designierten Instituten Standards bereitgestellt und auch weiterentwickelt. Die primären metrologischen Standards beruhen auf SI-Einheiten und sind die Basis für eine Rückführbarkeit der Sensoren bzw. Analysengeräte.
The success of this energy transition and the efficient utilization of green hydrogen as a pristine energy carrier hinge upon the cultivation of hydrogen readiness, swift market expansion, and the establishment of crucial value chains within national and European contexts. Paramount to these objectives are reliable quality and safety standards, essential for ensuring supply safety, environmental compatibility, and instilling confidence in these technologies.
In the realm of safety management systems, gas sensors emerge as vital components for detecting hydrogen. This presentation delves into the imperative role of hydrogen systems, emphasizing their capability to monitor and control operations, issue warnings, signal hazardous conditions, and sound alarms. It explores the intricate landscape of functional safety considerations and addresses the challenges associated with measurement uncertainty in sensor testing.
A diverse array of sensors catering to hydrogen, pressure, temperature, and flow are available, each contributing significantly to the safety and efficiency of hydrogen technologies. Applications are envisaged to adhere meticulously to quality infrastructural regulations, codes, and standards, ensuring seamless integration and operation within the broader hydrogen ecosystem.
This discussion underscores the ubiquitous presence of sensor systems across various fields within hydrogen technologies, illustrating their multifaceted contributions to safety, reliability, and overall success in realizing the transformative potential of green hydrogen.
A vast number of emerging pollutants is being detected in the environment. Another lingering problem are health-threatening contaminants, such as mycotoxins, that deteriorate food and feed, and the pathogens themselves. Analytical methods, suitable for trace analysis, are needed that are desirably also fast, inexpensive and, if possible, robust and portable. It is set out, how immunoana-lytical, i.e., antibody-based methods, which are elaborated in a broad range of formats, can be profitably used to gain insights on the distribution and concentration trends of the target analytes at the point-of-need.
The presentation deals with the progess, the use of beads brings with it when developing and using immunoanalytical methods. While with conventional assays (e.g. ELISA) fill/empty/wash steps have to be performed within the same microplate well, antibodies on beads bring the possibility of incubating the sample with the capture antibodies in one compartment and then transport it, e.g. in microfluidic channels, to the site of detection. Especially magnetic nanoparticles, that can be captured and released easily, have a wide field of application.
Integrating fluorescent probes with sensing matrices presents a major challenge because usually, when confined in a rather rigid matrix, fluorophores tend to behave completely different than for instance in the molecular state in solution. The lecture reviews the major strategies that have been devised recently to circumvent such issues with special focus on the works carried out in this field by BAM’s Chemical and Optical Sensing Division. Moreover, it will be shown that by using certain strategies not only can the response behavior be retained but synergistic effects can even endow the hybrid with a much better performance than the probe molecule alone.
Macrocycle-containing fluorescent probes continue to be one of the most popular classes of indicator molecules for the sensitive optical detection of ionic inorganic analytes, in particular metal ions, since the first integration of crown ether building blocks into chromophoric π systems more than 30 years ago. However, whereas a large multitude of such probes have been described for operation in organic or mixed aqueous environments, the step to realistic analytical media such as water samples, aqueous food extracts or body fluids is still scarce. On one hand, this is due to considerably low complex stability constants for instance for alkali and alkaline-earth metal ions. On the other hand, many classes of organic dyes that show favourable spectroscopic properties and ion-induced responses in organic solvents are not soluble in neat aqueous media and/or exhibit only significantly quenched fluorescence, even if transition metal ions are binding strongly to the receptor unit. A way to circumvent such problems in a rather simple manner is the steric incorporation of fluorescent probes into mesoporous silica nanomaterials. The local polarity in such pores, whether nascent or modified appropriately with functional silanes, resembles much more a quasi-organic environment while at the same time allowing for free diffusion of water and its cargo.
Two examples of powerful hybrid signalling systems will be presented, utilizing charge transfer-type indicator molecules that show inferior sensing properties in their molecular state. One example discusses mercury(II) determination over an extended concentration range and the other discusses silver(I) and mercury(II) discrimination simply on the basis of photophysical effects retained in the hybrid materials.
Since more than 20 years, optical spectroscopic techniques, in particular fluorescence-based methods, are on the rise in many different areas of chemical and biochemical analysis, with no end being in sight.1,2 Advances in miniaturization and remote applications on one hand and ground-breaking developments in microscopy and laser-based high-throughput instrumentation on the other hand have fuelled these developments substantially.3,4 At the core of utmost of these applications however is not only the instrument, but a small entity that is able to absorb and emit photons and thus to report on the actual (bio)chemistry that is going on in a particular sample of interest.5,6 Besides intense research on various types of luminescent particles (e.g., quantum dots and carbon dots) and proteins, dye chemistry has thus seen its revival and the number of publications dealing with the design, synthesis and application of new fluorescent dyes as probes, stains, labels or indicators is still continuing to grow.
Among the various classes of dyes available as bright fluorophores for a wavelength range that is compatible with many (bio)analytical applications and the respective instrumentation, in particular pyrrolic dyes that do not belong to the classical porphyrins or phthalocyanines have received strong attention recently. Starting perhaps with the revival of the traditional boron-dipyrromethene laser dye ca. 15 years ago,7 these so-called BODIPYs have developed into a colourful spectrum of different derivatives.8 However, the interest in expanding the range of pyrrole-containing π-systems beyond BODIPYs has also constantly increased and has brought about several other pyrrole-based ring systems such as diketopyrrolopyrroles9 or dipyrrolonaphthyridinediones which possess a favourable brightness and other interesting properties. The present contribution will give a critical overview of the field, pinpointing advantages and prospects as well as discussing potential aspects of improvement with an emphasis on the chemical sensing and the longer wavelength range.
Photoluminescence applications in the life and material sciences require bright molecular and nanocrystalline emitters, stimuli-responsive optical probes, signal enhancement, multiplexing, and barcoding strategies and traceable methods to quantify the signal-relevant optical properties of luminescent materials at the ensemble and single molecule/particle level. In this context, current research at Division Biophotonics of BAM is presented ranging from dye and nanocrystal photophysics, absolute measurements of photoluminescence quantum yields in the UV/vis/NIR/SWIR, lifetime multiplexing, and the development of different types of fluorescence standards for validating optical-spectroscopic measurements.