Magneto resistance sensors like GMR (giant magneto resistance) or TMR (tunnel magneto resistance) are widely used in industrial applications, examples are position measurement and read heads of hard disk drives. However, in case of non-destructive testing (NDT) applications these sensors, although their properties are outstanding like high spatial resolution, high field sensitivity, low cost and low energy consumption, never reached a technical transfer to an application beyond sci-entific scope.
This paper deals with benefits of GMR/TMR sensors in terms of high spatial resolution testing for different NDT applica-tions. The first example demonstrates the preeminent advantages of MR-elements compared with conventional coils used in eddy current testing (ET). The probe comprises one-wire excitation with an array of MR elements. This led to a better spatial resolution in terms of neighboring defects.
The second section concentrates on MFL-testing (magnetic flux leakage) with active field excitation during and before test-ing. The latter illustrated the capability of highly resolved crack detection of a crossed notch. This example is best suited to show the ability of tiny magnetic field sensors for magnetic material characterization of a sample surface. Another example is based on characterization of samples after tensile test. Here, no external field is applied. The magnetization is only changed due to external load and magnetostriction leading to a field signature which GMR sensors can resolve. This gives access to internal changes of the magnetization state of the sample under test.
The use of composite pressure vessels instead of conventional vessels made of steel or aluminum grew strongly over the last decade. The reason for this trend is the tremendous weight saving in case of composite vessels. However, the long-time behavior is not fully understood for filling and discharging cycles and creep strength and their influence on the CFRP coating (carbon fiber reinforced plastics) and the internal liner (steel, aluminum, or plastics). The CFRP ensures the pressure resistance while the inner liner is used as container for liquid or gas. To overcome the missing knowledge of ageing BAM started an internal project to investigate degradation of these material systems. Therefore, applicable testing methods like eddy current testing are needed. Normally, high-frequency eddy current testing (HF-ET, f > 10 MHz) is deployed for CFRP due to its low conductivity of the fiber, which is in the order of 0.01 MS/s, and the capacitive coupling between the fibers. Nevertheless, in some cases conventional ET can be applied. We show a concise summary of studies on the application of conventional ET of composite pressure vessels.
Magneto resistive (MR) sensors are suited for a wide range of different applications. Especially due to their small sizes and their frequency-independent behaviour, they are eligible candidates for non-destructive testing methods where high spatial resolution is required. The use of specialized magnetic field probes enables not only a defect evaluation, but also a localized characterization of ferromagnetic materials.
This paper presents some NDT (non-destructive testing) examples concerning magnetic flux leakage applications (MFL) and eddy current testing (ET). For MFL-testing we used an NDT-adapted GMR (Giant MR) sensor array for the detection of small inclusions in thin steel sheets. We also investigated the effects of microstructure on magnetic properties using GMR sensors. The ET-example describes an MR array probe consisting of 32 MR-elements, an ASIC, subsequent readout components and a one-wire excitation to generate eddy currents inside the material (developed in the EU-funded IMAGIC-project, 2011-2014, 7th Framework Programme). Using this MR-probe we achieved results with a better spatial resolved defect detection of neighbouring boreholes compared to “conventional” ET-probes.
Evaluation of high spatial resolution imaging of magnetic stray fields for early damage detection
(2017)
The paper discusses the evaluation of elastic and plastic strain states in two low-carbon steels of the same steel group with high spatial resolution GMR (giant magneto resistance) sensors. The residual stress distributions of tungsten inert gas welded plates were determined by means of neutron diffraction as a reference. The normal component of local residual magnetic stray fields arise in the vicinity of the positions of maximum stress. The experiments performed on flat tensile specimen indicate that the boundaries of plastic deformations are a source of stray fields. The spatial variations of magnetic stray fields for both the weld and the tensile samples are in the order of the earths magnetic field.
Development of adapted GMR-probes for automated detection of hidden defects in thin steel sheets
(2016)
Thin steel sheets with a thickness of 0.3 mm and less are the base materials of many everyday life products (cans, batteries, etc.). Potential inhomogeneities such as non-metallic inclusions inside the steel can lead to a rupture of the sheets when it is formed into a product such as a beverage can. Therefore, there is a need to develop automated NDT techniques to detect hidden defects and inclusions in thin sheets during production. For this purpose Tata Steel Europe and BAM, the Federal Institute for Materials Research and Testing (Germany), collaborate in order to develop an automated NDT-system. Defect detection systems have to be robust against external influences, especially when used in an industrial environment. In addition, such a facility has to achieve a high sensitivity and a high spatial resolution in terms of detecting small inclusions in the μm-regime. In a first step, we carried out a feasibility study to determine which testing method is promising for detecting hidden defects and inclusions inside ferrous thin steel sheets. Therefore, two methods were investigated in more detail – magnetic flux leakage testing (MFL) using giant magneto resistance sensor arrays (GMR) as receivers [1,2] and eddy current testing (ET). The capabilities of both methods were tested with 0.2 mm-thick steel samples containing small defects with depths ranging from 5 μm up to 60 μm. Only in case of GMRMFL-testing, we were able to detect parts of the hidden defects with a depth of 10 μm trustworthily with a SNR better than 10 dB. Here, the lift off between sensor and surface was 250 μm. On this basis, we investigated different testing scenarios including velocity tests and different lift offs. In this contribution we present the results of the feasibility study leading to first prototypes of GMR-probes which are now installed as part of a demonstrator inside a production line.
Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications.
This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects.
The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques.
*The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France).
At BAM, the Federal Institute for Materials Research and Testing, a group of scientists develops NDT-applications based on GMR sensor technology. In particular, the knowledge gained in the field of automated testing systems based on the magnetic flux leakage (MFL) were combined with GMR sensors to achieve high resolution testing of ferromagnetic materials.
In cooperation with Europe's second largest steel producer, Tata Steel Europe, BAM is working on solutions for the detection of small inhomogeneities in thin steel plates. The objective is to incorporate an automated testing facility in a production line.
Before setting up an automated testing system, a feasibility study was carried out in order to verify the ability of GMR-MFL-testing and eddy current testing (ET) for the detection of hidden defects in thin steel plates. For this purpose, Tata Steel Europe fabricated in a first step test samples of 0.2 mm thick steel plates in which defects of different depth (5 – 60 µm) were introduced. Only in case of GMR-MFL-testing, we were able to detect parts of the hidden defects trustworthily with a SNR better than 10 dB. The lift off between sensor and surface was 250 ìm. On this basis, we investigated different testing scenarios including velocity tests and different lift offs. The achieved results for this special testing problem were presented leading to a practical example for GMR-based testing and paving the way to an automated testing system in a production line.
We present a simulation study which pursues the objective to find probe geometries for a MR-based eddy current (EC) probe (MR magneto resistance, e.g., GMR giant magneto resistance, TMR tunnel magneto resistance). MR sensor technology exhibits two significant advantages compared with conventional coil systems. First, MR sensors are relatively frequency-independent within common EC-frequency ranges which enable us to operate them in hidden defects testing problems. Secondly, MR technology is well suited for miniaturization helping us to design small elements in the order of below 100 µm. In this paper simulation and experimental results obtained with the probes for low frequency application, i.e. for hidden defects detection are discussed.
Our simulations are based on two different approaches for a better validation, a commercial finite element method software (Opera, Vectorfields) and the semi-analytical software CIVA. We investigated both coil arrangement in order to excite sufficient high eddy currents inside the test samples and position of MR-elements at the array chip. In doing so the MR sensors were positioned that they are not exposed to excitation fields. In addition, different coil geometries, in particular coil length, e.g. Ι = 20 mm, were analyzed in order to generate a consistent eddy current distribution beneath an array of up to 32 MR-elements. To prove obtained probe principles we built GMR-EC-probes. The first test measurements are in good agreement with the simulations performed by BAM and CEA. On basis of our findings the IMAGIC consortium developed new MR-EC-probes using integrated ASIC technology.
We present a prototype for automated magnetic stray field testing of ferromagnetic roller bearings. For this purpose NDE-adapted GMR sensor arrays (giant magneto resistance) are used for the detection of surface breaking cracks. The sensors are miniaturized down to the lower µm-regime to achieve adequate spatial resolution. In doing so, sensor arrays with up to 48 elements are used to inspect the bearing surface within a few seconds only. In contrast to magnetic particle inspection (MPI), where the global magnetization requires a further inspection step and succeeding demagnetization, the presented prototype only locally magnetize the surface area in the vicinity of the GMR Sensors. For the local magnetization, the applied sub-surface magnetic field was simulated and proofed for detecting flaws with a depth of a few 10 µm. By multiplexing the sensor array with an adapted read out electronics we quasi simultaneously detect the normal field component of about 100µm above the surface. The detection of artificial notches with a depth of 40 µm and more could be resolved with a SNR better than 20 dB. The presented testing facility is fast and provides a step towards automated testing of safety relevant steel components.
Eddy Current Technique is a powerful method for detection of surface notches and of buried flaws during inspection of metallic parts. Recent EC array probes have demonstrated a fast and efficient control of large surfaces. Nevertheless, when the size of flaws decreases or the defect is rather deep, traditional winding coil probes turn out to be useless. Magnetoresistive sensors present the advantages of flat frequency response and micron size. These sensors are hence very attractive for the detection of buried defects that require low frequencies because of skin depth effect. An optimization of the probe with magnetoresistive sensors as receivers has been made by simulations using CIVA software and finite elements methods with OPERA. EC probes for buried flaw detection have been designed. Experimental results have been compared with simulations.