Filtern
Erscheinungsjahr
- 2004 (7) (entfernen)
Dokumenttyp
- Beitrag zu einem Sammelband (7) (entfernen)
Referierte Publikation
- nein (7)
Schlagworte
- Radar (3)
- Radiografie (3)
- Zerstörungsfreie Prüfung (3)
- Baudenkmäler (2)
- Digitale Radiologie (2)
- Laminografie (2)
- Mobile Anwendungen (2)
- Strukturaufklärung (2)
- Videoskopie (2)
- Baudenkmal (1)
The detection of defects in aircraft components or parts of a power plant or mines in the ground is connected with the task to distinguish between signals caused be the item searched for and noisy signals from other sources. The reliability of the system is the better the better the system is in detecting the wanted signal and avoiding false alarms caused by noise. It is usual to measure the reliability of diagnostic systems in terms of ROC-curves (Re-ceiver Operating Characteristics) and POD-curves (Probability of Detec-tion). The ROC curves describe the POD versus Probability of False Alarm with growing system sensitivity along the curve. POD curves describe the Probability of Detection for a fixed sensitivity for a variation of item sizes or depths. Reliability of the whole system is always a composition of the physics
and technique, application influences and the human factors. For the scien-tific understanding and possibilities of improvement, decomposition accord-ing to a modular model is helpful. The authors present their experiences with the reliability evaluation of metal detectors for humanitarian demining and an NDT system of mechanized ultrasonic phased array testing of copper welds. The special concern in demining is the influence of soil types, detec-tors and the experiences of human beings.
In diesem Beitrag wird die Anwendung von Radiographiesystemen zum Auffinden von Holzschäden beschrieben. Die Anlage besteht aus einer mobilen Röntgenblitzröhre und einem digitalen Radiographiesystem mit Speicherfolie oder einem Flachdetektor. An Hand der durchgeführten Versuche an Laub- und Nadelbäumen sowie an Eichenbalken der Marienkirche der Lutherstadt- Wittenberg wird die Detektion innerer Schäden gezeigt.
Tomographical Computer Aided Radiology (TomoCAR) is based on the mechanical position control of
an X-ray tube in front of a welding seam and the application of a planar array detector behind it. Several hundred
radiometric projections in small angle steps are acquired. The tomographical reconstruction allows the three-dimensional
(3D) representation of the defects. A new radiometric array detector system with a small internal
unsharpness and high image contrast is used for the 2- and 3-dimensional visualization and sizing of planar defects
with a defect opening of less than 100 µm. This detector is based on a CMOS-flat panel with a direct converting
CdTe-single crystal layer. The small design allows the application of the mobile testing equipment for mechanized
X-ray inspection in industrial plants. The physical pixel size of the detector amounts to 0,1x0,1 mm². Nevertheless,
this system yields a better spatial resolution than indirect converting detectors (e.g. cameras with fluorescence
layers of Gd2O2S). It allows the reliable detection of planar defects with openings far below the detector pixel size
by subpixel resolution.
'TomoCAR' is qualified at present in the context with a German pilot study following to the ENIQ guidelines for
the employment within the nuclear power industry.