Filtern
Erscheinungsjahr
- 2018 (10) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (10)
Sprache
- Englisch (10)
Referierte Publikation
- ja (10) (entfernen)
Schlagworte
- Fluorescence (6)
- BODIPY dyes (2)
- Mercury (2)
- Microfluidics (2)
- Test strips (2)
- Adulteration (1)
- Anilinopyridine (1)
- Anion receptors (1)
- BODIPY (1)
- Biosensor (1)
Organisationseinheit der BAM
Invited for this month’s cover picture is the group of Dr. Knut Rurack at the Department of Analytical Chemistry; Reference Materials at the Bundesanstalt fuer Materialforschung und -pruefung (BAM) in Berlin (Germany). The cover picture shows how differences in color and fluorescence on a test strip can be easily read out with a mobile device. Two reference spots Frame the sensitive spot that indicates the presence of trace amounts of HgII below the threshold in a natural water sample. This dipstick contains a hybrid material that combines boron-dipyrromethene (BODIPY) probes sterically loaded into specifically tailored mesoporous silica particles, allowing for ultrasensitive HgII detection through enhanced fluorescence in a few seconds. The applicability in real water samples and fish extracts are also studied.
Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids
(2018)
Quick but accurate testing and on‐the‐spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut‐off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over‐the‐counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on‐site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme‐linked immunosorbent assay (ELISA) performed on antibody‐grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen‐printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L.
Three fluorescent molecular rotors of 4-dimethylamino-4-nitrostilbene (4-DNS) were investigated for their potential use as viscosity probes to indicate the content of kerosene in diesel/kerosene blends, a wide-spread activity to adulterate fuel. In solvents with low viscosity, the dyes rapidly deactivate via a so-called twisted intramolecular charge transfer state, efficiently quenching the fluorescence. Measurements of diesel/kerosene blends revealed a good linear correlation between the decrease in fluorescence and the increase of the fraction of the less viscous kerosene in diesel/kerosene blends. Immobilization of the hydroxy derivative 4-DNS-OH in cellulose paper yielded test strips that preserve the fluorescent indicator's behavior. Combination of the strips with a reader based on a smartphone and a controlling app allowed to create a simple field test. The method can reliably detect the presence of kerosene in diesel from 7 to 100%, outperforming present standard methods for diesel adulteration.
The synthesis, characterization, and application of mesoporous materials containing boron–dipyrromethene (BODIPY) moieties that allow the sensitive and selective detection of HgII in aqueous environments by fluorescence enhancement is reported. For this purpose, BODIPY dye I containing a thia‐aza crown ether receptor as the fluorescent probe for the detection of HgII in aqueous environments is encapsulated into mesoporous materials to avoid self‐quenching or aggregation in water. Determination of HgII is accomplished within a few seconds with high selectivity and sensitivity, reaching a limit of detection of 12 ppt. The determination of trace amounts of HgII in natural waters and in fish extracts is demonstrated by using our sensing material. The incorporation of the material into several μ‐PAD strips yields a portable, cheap, quick, and easy‐to‐handle tool for trace HgII analysis in water.
We introduce herein boron-dipyrromethene (BODIPY) dyes as a new class of fluorophores for the design of reporter dyes for supramolecular host–guest complex formation with cucurbit[7]uril (CB7). The BODIPYs contain a protonatable aniline nitrogen in the meso-position of the BODIPY chromophore, which was functionalized with known binding motifs for CB7. The unprotonated dyes show low fluorescence due to photoinduced electron transfer (PET), whereas the protonated dyes are highly fluorescent. Encapsulation of the binding motif inside CB7 positions the aniline nitrogen at the carbonyl rim of CB7, which affects the pKa value, and leads to a host-induced protonation and thus to a fluorescence increase. The possibility to tune binding affinities and pKa values
is demonstrated and it is shown that, in combination with the beneficial photophysical properties of BODIPYs, several new applications of host–dye reporter pairs can be implemented. This includes indicator displacement assays with favourable absorption and
emission wavelengths in the visible spectral region, fluorescence correlation spectroscopy, and noncovalent surface functionalization
with fluorophores.
Small-molecule oxoanions are often imprinted noncovalently as carboxylates into molecularly imprinted polymers (MIPs), requiring the use of an organic counterion. Popular species are either pentamethylpiperidine (PMP) as a protonatable cation or tetraalkylammonium (TXA) ions as permanent cations. The present work explores the influence of the TXA as a function of their alkyl chain length, from methyl to octyl, using UV/vis absorption, fluorescence titrations, and HPLC as well as MD simulations. Protected phenylalanines (Z-L/D-Phe) served as templates/analytes. While the influence of the counterion on the complex stability constants and anion-induced spectral changes shows a monotonous trend with increasing alkyl chain length at the prepolymerization stage, the cross-imprinting/rebinding studies showed a unique pattern that suggested the presence of adaptive cavities in the MIP matrix, related to the concept of induced fit of enzyme−substrate interaction. Larger cavities formed in the presence of larger counterions can take up pairs of Z-X-Phe and smaller TXA, eventually escaping spectroscopic detection. Correlation of the experimental data with the MD simulations revealed that counterion mobility, the relative distances between the three partners, and the hydrogen bond lifetimes are more decisive for the response features observed than actual distances between interacting atoms in a complex or the orientation of binding moieties. TBA has been found to yield the highest imprinting factor, also showing a unique dual behavior regarding the interaction with template and fluorescent monomer. Finally, interesting differences between both enantiomers have been observed in both theory and experiment, suggesting true control of enantioselectivity. The contribution concludes with suggestions for translating the findings into actual MIP development.
Probe 1, which contains an anilinopyridine chromophore and an azaoxa macrocyclic subunit, presented an absorption band centered at 340 nm in acetonitrile. Addition of Fe(III), Cr(III) and Hg(II) induced the growth of a new absorption band at 430 nm (with color change from colorless to yellow), whereas in the presence of Cu(II), Zn(II) and Pb(II), less marked changes were observed. The color changes observed upon addition of Fe(III), Cr(III) and Hg(II) were ascribed to the formation of 1:1 stoichiometry complexes with probe 1. Coordination of Fe(III), Cr(III) and Hg(II) with the pyridine fragment of 1 induced an enhancement of the charge transfer character accompanied with a marked bathochromic shift that was reflected in a color change from colorless to yellow. The strength of the interaction between probe 1 and Fe(III) cation was modulated upon interaction with anions. Of all the anions tested, only cyanide was able to induce the bleaching of the yellow 1·Fe(III) complex solution. This bleaching was ascribed to
the formation of 1·Fe(III)-CN complex that restored, to some extent, the optical features of the free probe allowing the chromogenic sensing of cyanide. Besides, 1·Fe(III) complex was used to detect
cyanide in acetonitrile-water 90:10 v/v mixtures with good recoveries.
Because of the globally increasing prevalence of diabetes, the need for accurate, efficient and at best miniaturized automated analytical systems for sugar detection in medical diagnostics and the food industry is still urgent. The development of molecular probes for sugars based on boronic acid receptors offers an excellent alternative to the kinetically slow enzyme-based sugar sensors. Moreover, by coupling such chelating units with dye scaffolds like BODIPYs (boron–dipyrromethenes), highly fluorescent sugar sensing schemes can be realized. In this work, a boronic acid-functionalized BODIPY probe was developed, which binds selectively to fructose’s adjacent diols to form cyclic boronate esters. Placement of an amino group in direct neighborhood of the boronic acid moiety allowed us to obtain a broad working range at neutral pH, which distinguishes the probe from the majority of systems working only at pH > 8, while still meeting the desired sensitivity in the micro-molar range due to a pronounced analyte-induced fluorescence increase. To enhance the applicability of the test in the sense described above, integration with a microfluidic chip was achieved. Here, fructose was selectively detected by fluorescence with similar sensitivity in real time on chip, and an assay for the straightforward detection of sugar in (colored) sodas without sample clean-up was established.
Highly emissive phenanthrene-fused boron–dipyrromethene (PBDP) dyes have been spectroscopically characterized in a series of solvents. The influence of different substituents (-H,
-I, -CN, -DMA or a 15C5-crown ether) in the para-position of a phenyl ring attached to the meso-position of the BODIPY core is discussed. This family of dyes has an intense emission at lambda > 630 nm, with fluorescence quantum yields between 0.7 and 1.0 in all solvents studied, except in the case of the dimethylamino-substituted
derivative, PBDP-DMA, which undergoes excited-state intramolecular charge transfer (CT), leading to broadband dual fluorescence in highly polar solvents. Introduction of a weaker electron donor such as a benzocrown to the meso-position is not able to trigger a second (charge or electron transfer) process and, interestingly, heavy atom (iodine, PBDP-I derivative) substitution at that moiety does also not have a relevant influence on the photophysics, i.e., enhanced intersystem crossing was not observed.
Electrochemical studies of PBDP-DMA complement the data reported and stress the fact that the decrease in fluorescence of PBDP-DMA in highly polar solvents is due to an excited-state CT process
rather than to a photoinduced electron transfer (PET).
Fluorescent sensory MIP (molecularly imprinted polymer) particles were combined with a droplet-based 3D microfluidic system for the selective determination of a prototype small-molecule analyte of environmental concern, 2,4-dichlorophenoxyacetic acid or 2,4-D, at nanomolar concentration directly in water samples. A tailor-made fluorescent indicator cross-linker was thus designed that translates the binding event directly into an enhanced fluorescence signal. The phenoxazinone-type cross-linker was co-polymerized into a thin MIP layer grafted from the surface of silica microparticles following a RAFT (reversible addition-fragmentation chain transfer) polymerization protocol. While the indicator cross-linker outperformed its corresponding monomer twin, establishment of a phase-transfer protocol was essential to guarantee that the hydrogen bond-mediated signalling mechanism between the urea binding site on the indicator cross-linker and the carboxylate group of the analyte was still operative upon real sample analysis. The latter was achieved by integration of the fluorescent core-shell MIP sensor particles into a modular microfluidic platform that allows for an in-line phasetransfer assay, extracting the analyte from aqueous sample droplets into the organic phase that contains the sensor particles. Real-time fluorescence determination of 2,4-D down to 20 nM was realized with the system and applied for the analysis of various surface water samples collected from different parts of the world.