Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (79) (entfernen)
Schlagworte
- Non-destructive testing (79) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (27)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (13)
- 8.0 Abteilungsleitung und andere (10)
- 8.5 Röntgenbildgebung (4)
- 8.4 Akustische und elektromagnetische Verfahren (3)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- 6 Materialchemie (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7 Bauwerkssicherheit (1)
Decades of non-destructive evaluation (NDE) for the quality assurance of concrete bridges revealed the necessity of developing procedures for building reference specimens for different defects. External objects have been widely used in specimen construction to represent defects. However, embedded materials can alter the actual defect characteristics, interrupting the NDE responses. This study proposes new approaches to fabricating reference specimens for reinforced concrete that feature substantial defects, including cracks, delamination, honeycombing and rebar corrosion, without external objects. As a result, realistic responses can be acquired to identify promising NDE methods for characterising actual deteriorations. The procedures were produced with the intent of being reproducible in any laboratory. Destructive and non-destructive testing methods were performed to verify the effectiveness of the processes in creating defects. This study provides research laboratories with techniques for
fabricating reference specimens for characterising defects and assessing the performance of NDE technologies.
Application of synchrotron infrared radiation in the study of organic coatings in cross-sections
(2008)
Validation of non-destructive testing methods is necessary to create a common basis where different systems can be compared and their applications and limitations be identified. This can be achieved through comparing the measurements taken by several systems used for a common diagnostic purpose under practical but controlled testing conditions. Well-designed small and large laboratory or field specimens promise such conditions.
The special concrete specimen (LCS) at BAM was constructed for validation purposes, in particular, to be used for evaluating the performance of echo methods. The thickness of the specimen is varying and it contains carefully designed built-in faults, such as voids, honeycombs and tendon ducts with various degrees of grouting defects. Since the geometry and condition of the defects are known, it can be used to compare the performance of radar, ultrasonic, impact-echo. The research was conducted within the Research group FOR384, sponsored by the German Research Society DFG.
Visually detecting irregularities on components is a complex process, influenced by physical, technical, and human factors. Current standards mainly focus on illuminance, demanding highest accuracy for it, without providing scientific justification. In this research, 63 inspectors visually inspected forgings, with and without crack-like indications. The influence of illuminance on probability of detection was investigated. Therefore, illuminance was varied in three steps (200 lx, 350 lx, 500 lx). Human factors (e.g., experience, motivation) were recorded by using questionnaires. The results show no significant difference in probability of detection between the three illuminance levels. Equal probability of detection rates could be achieved at illuminances below and at the required threshold (500 lx). A difference in illuminance was found between the measurement point and the test area of the respective participant. This leads to higher assumed illuminance than present on the component. Compared with the measurement accuracy of the used illuminance meter, none of these deviations could be used to explain the similar results at different illuminance. The fact that illuminance has a significant influence in detecting indications has been disproven for this case. Whether human factors can provide explanation for the results remains unclear. This will be investigated in further research.
Dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT), combining strong piezoelectric response with a low density and softness, evidence their high potential for the air-coupled ultrasonic applications. The disadvantage of the low coupling factor is compensated by the extremely low acoustic impedance, which provides excellent matching to air and promises efficient sound transmission through the airtransducer interface. The influence of the electrodes on the electromechanical properties was investigated. Electron beam evaporation technology was adapted to the EMFIT films, and films with both-sided Au and Al electrodes were prepared without reducing or suppressing of the electromechanical properties. Finally, prototype transducers based on the EMFIT films were developed. In spite of the simple construction and absence of matching layers, high sensitivity of the EMFIT transducers was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging and testing with EMFIT transducers is possible.
Case studies
(2013)
In this paper, some quite different survey tasks are described, and it can be seen that corrosion surveys will follow a certain scheme of data acquisition (first NDT measurements, than detailed testing on suspect areas), but the individual scope of on-site measurements may have a vast variety according to the local circumstances, and the interpretation always has to refer to a wider set of information than the data readings only.
Development of an Accurate and Robust Air-Coupled Ultrasonic Time-of-Flight Measurement Technique
(2022)
Ultrasonic time-of-flight (ToF) measurements enable the non-destructive characterization of material parameters as well as the reconstruction of scatterers inside a specimen. The time-consuming and potentially damaging procedure of applying a liquid couplant between specimen and transducer can be avoided by using air-coupled ultrasound. However, to obtain accurate ToF results, the waveform and travel time of the acoustic signal through the air, which are influenced by the ambient conditions, need to be considered. The placement of microphones as signal receivers is restricted to locations where they do not affect the sound field. This study presents a novel method for in-air ranging and ToF determination that is non-invasive and robust to changing ambient conditions or waveform variations. The in-air travel time was determined by utilizing the azimuthal directivity of a laser Doppler vibrometer operated in refracto-vibrometry (RV) mode. The time of entry of the acoustic signal was determined using the autocorrelation of the RV signal. The same signal was further used as a reference for determining the ToF through the specimen in transmission mode via cross-correlation. The derived signal processing procedure was verified in experiments on a polyamide specimen. Here, a ranging accuracy of <0.1 mm and a transmission ToF accuracy of 0.3μs were achieved. Thus, the proposed method enables fast and accurate non-invasive ToF measurements that do not require knowledge about transducer characteristics or ambient conditions.
This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pitot tube. The three-dimensional acoustic data of both devices has been acquired using a calibrated microphone. The distribution of characteristic acoustic properties of both transducers are extracted and given in addition to the raw data. The data presented in the article will be a valuable source for reference and validation, both for developing fluidic and alternate ultrasound generation technologies. Furthermore, they will give additional insight into the acoustic-flow interaction phenomena of high speed switching devices. This article is accompanying the paper Experimental Analysis of the Acoustic Field of an Ultrasonic Pulse Induced by a Fluidic Switch (Bühling et al., 2021) published in The Journal of the Acoustical Society of America, where the data is interpreted in detail and the rationale for characteristic sound properties of the fluidic transducer are given.
AbstractAir‐coupled ultrasonic testing (ACU) is a pioneering technique in non‐destructive testing (NDT). While contact testing and fluid immersion testing are standard methods in many applications, the adoption of ACU is progressing slowly, especially in the low ultrasonic frequency range. A main reason for this development is the difficulty of generating high amplitude ultrasonic bursts with equipment that is robust enough to be applied outside a laboratory environment. This paper presents the fluidic ultrasonic transducer as a solution to this challenge. This novel aeroacoustic source uses the flow instability of a sonic jet in a bistable fluidic switch to generate ultrasonic bursts up to 60 kHz with a mean peak pressure of 320 Pa. The robust design allows operation in adverse environments, independent of the operating fluid. Non‐contact through‐transmission experiments are conducted on four materials and compared with the results of conventional transducers. For the first time, it is shown that the novel fluidic ultrasonic transducer provides a suitable acoustic signal for NDT tasks and has potential of furthering the implementation of ACU in industrial applications.This article is protected by copyright. All rights reserved
Ultrasonic testing is a widely applied measurement method in materials research and medicine. Commonly, a transducer is coupled to the specimen directly or via a liquid coupling agent. While reducing acoustic transmission losses significantly, this procedure is time-consuming and cannot be used for sensitive specimens. Air-coupled ultrasound is a viable alternative in such cases, although suffering from very high acoustic transmission losses between transducer, air and specimen. The recently introduced fluidic transducer (FT) generates ultrasound by utilizing the instability of a supersonic air jet switched inside a fluidic amplifier. Since only air is used as the working medium and no vibrating surfaces are used for ultrasound generation, the transducer is able to efficiently generate large acoustic pressure amplitudes. The resulting acoustic field shares its directivity with the ejected high-velocity air jet. Thus, the acoustic energy needs to be redirected from the jet axis in order to make the fluidic transducer applicable to sensitive specimens. In this study, the effectivity of using sonic crystals (SCs) for this redirection is investigated using acoustic and flow measurements. SCs are air-permeable while being reflective to large acoustic frequency bands. It was shown that both a defect waveguide and a mirroring strategy successfully redirected the acoustic field from the air jet. Furthermore, the interaction of flow and SC showed strong acoustic quenching if the SC was placed too close to the FT outlet. Blockage of the jet entrainment due to the SC may result in slightly higher off-axis flow velocities locally, which should be considered in sensitive applications.