Filtern
Erscheinungsjahr
- 2010 (19) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (19) (entfernen)
Referierte Publikation
- ja (19) (entfernen)
Schlagworte
- Alternariol (2)
- Degradation (2)
- Epimerization (2)
- HPLC-MS/MS (2)
- SPE (2)
- Tenuazonic acid (2)
- 2,4-Dinitrophenylhydrazine (1)
- AHTN (1)
- AHTN-COOH (1)
- Active sampling (1)
Commercially available linear alkylbenzenesulfonates (LASs) are a mixture of various homologues and isomers, leading to 20 major species. In this work we investigated the commercial product by liquid chromatography-solid phase extraction-nuclear magnetic resonance spectroscopy-mass spectrometry (LC-SPE-NMR/MS). The commercial product was separated into 17 fractions by liquid chromatography (LC). After chromatographic separation, 5% of the flow was split to a mass spectrometer (MS) while 95% was send to post-column solid phase extraction cartridges for enrichment of the analytes (LC-SPE). After elution from the SPE-cartridges a NMR-spectrometer equipped with a cryo-probe was used for the characterisation of the different LASs species. For the first time H-1-1D and H-H-COSY spectra for 14 LASs species out of 20 major isomers are presented, whereas the 6 remaining species are detected as mixtures in 3 H-1-1D and H-H-COSY spectra. These data were used to correlate the chromatographic retention of the LASs isomers to the substitution pattern of the alkyl chain.
HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers
(2010)
Der Einsatz aktiver (Pumpprobennahme,
Schöpfprobennahme) und passiver (Diffusionsprobennahme)
Probennahmetechniken zur Gehaltsbestimmung von
LHKW sowie Ethen und Methan in Grundwasser wird aus
ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit
von Analysendaten untersucht. Am Beispiel einer Kontamination
mit Trichlorethen sowie 1,2-Dichlorethen und
Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit
der passiven Probennahme durch unzureichende
Strömungsverhältnisse im Aquifer sowie biologische
Aktivität im Pegelrohr begrenzt ist. Der aktiven Probennahme
ist bei ungeklärten oder unzureichenden Strömungsverhältnissen
im Grundwasserleiter daher der Vorzug
zu geben. Das gaschromatographische Verfahren für Vinylchlorid
mittels Dampfraumtechnik wird um die Quantifizierung
von Methan und Ethen erweitert. Dabei werden für
die Bewertung von Altlasten relevante Bestimmungsgrenzen
von 0,1 µg/l (Vinylchlorid, Ethen) sowie 5 µg/l (Methan)
erreicht.
Aus der Validierung der Analysenmethode und den
Ergebnissen verschiedener Probennahmen werden Toleranzbereiche
für die Ergebnisse eines Grundwassermonitorings
abgeschätzt. Diese Streubreiten von Monitoring-
Ergebnissen sollten von Ingenieurbüros und zuständigen
Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse
eines LHKW-Grundwasserschadens beachtet
werden.
High-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) was applied to sterospecifically quantify the content of α-, β-, and γ-hexabromocyclododecane (HBCD) in six fish species from the Norwegian Etnefjorden. A combination of a β-PM cyclodextrin and an achiral column enabled the paired chromatographic separation of the stereoisomers in the order (-)-α-, (+)-α-, (-)-β-, (+)-β-, (+)-γ- and, (-)-γ-HBCD. The limits of detection were in the range of 6–21 pg g-1 depending on the stereoisomer and the concentrations of α-, β-, and γ-HBCD in fillets ranged from <5.4 ng g-1 to 11.1 µg g-1 lipid weight. α-HBCD enantiomers were throughout dominating, and in most cases the accumulation of the respective first eluted enantiomers ((-)-α-, (-)-β- and (+)-γ-HBCD) was observed. Deviations from the racemic EF-value were considered to be significant if it was outside of the expanded uncertainty range for each of the racemic HBCD-ratios. The composition of HBCD isomers varied between the investigated fish species and the relative high values for the γ-HBCD concentrations for the bottom-dwellers flounder and thorny skate seems to echo the HBCD pattern of ocean sediments.
Überwachung pflanzlicher Rohstoffe - Trichothecen-Analytik in Getreide und Getreideerzeugnissen
(2010)
A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM.
Sulfur dioxide (SO2) or sulfites are the most common preservatives used in winemaking. The level of total SO2 is subject to regulation. Currently, the regulatory determination of total SO2 (including sulfites) is done by the optimized Monier–Williams (OMW) method, which includes time-consuming distillation and titration steps. This paper describes the development and application of an alternative, rapid, straightforward, and reliable method for the determination of total sulfite in wine. In this method, a simple oxidation step using alkaline hydrogen peroxide (H2O2) solution is followed by ion chromatographic (IC) analysis of sulfate coupled with conductometric detection. Thirteen wines were analyzed in order to compare the in-sample oxidation method with the OMW-procedure. A t-test revealed satisfying compliance regarding sample preparation, i.e., alkaline H2O2 treatment and acidic distillation (OMW method). Comparable results were also obtained between IC analysis and acid/base titration. Our results indicate that the novel method (limit of quantification: 4 mg SO2 L-1) is well suited for the cost-efficient monitoring of regulatory limits.